§ 13-07-040 — Fire system
Municipal Code of the City and County of Broomfield, Colorado (Codified through Ordinance No. 2304, adopted May 26, 2026 (Supp. No. 54)) · Broomfield Municipal Code § 13-07-040
Corpus is an independent public-information project, not the official City of Broomfield website. Stable reference: corpuslaw.us/code/34920eed-82a8-4006-b420-d6ee66fec360
13-07-040 - Fire system.
(A) The chief of a fire department in the city, or his or her designee, shall have the authority to review the plans submitted for fire protection systems, approve the system installed, inspect the system and enforce the fire systems section herein. (B) Whenever practicable, water systems for fighting fire derived from a supply that cannot be approved as potable shall be kept wholly separate from drinking water pipelines, and equipment. Where the domestic water system is used for both drinking and firefighting purposes, approved backflow prevention devices shall be installed to protect individual drinking water lines that are not used for firefighting purposes. (C) Fire protection systems are classified as low hazard, moderate hazard, or high hazard, as follows: (1) A low hazard system is a single nonpumped system serving a building with a maximum height of thirty feet or a dry system. Backflow prevention devices required for a low hazard system are single detector check meter, alarm check valve, or single soft seat check valve. (2) A moderate hazard system is any wet system without corrosion prohibition or freeze protection chemicals. This may include systems with pumper connections, in-line booster pumps, private hydrants, or looped system. Backflow prevention devices required for a moderate hazard system are approved double check valve assembly or approved detector double check valve assembly. (3) A high hazard system is any system where an auxiliary water supply is permanently connected to the fire system, corrosion, prohibition, or antifreeze chemicals are used or a foamite installation is used. The backflow prevention device required for a high hazard system is an approved reduced pressure principal backflow device. (D) It is hereby declared that it is the responsibility of the person causing the introduction of unapproved or unsafe water into the city's pipeline during an emergency to see that a procedure to notify and protect customers of this piping system during the emergency is developed and implemented and that special precautions be taken to disinfect thoroughly and flush out all pipelines which may become contaminated before they are again used to furnish drinking water.
(Ord. 1796 §1, 2005)
Ask a question about Broomfield law
Corpus searches the Broomfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.