15-07-010 - Amendments to the Colorado Low Energy and Carbon Code.
The following amendments are hereby made to the Colorado Low Energy and Carbon Code: (A) Chapter 1 is hereby deleted. Refer to chapter 15-03, B.M.C., for administrative requirements. (B) Subsections C302 and R302, Design conditions, are hereby amended to read as follows: Section C302 Design conditions. The outdoor and interior design conditions shall be as established in Tables 302.1 and 302.2 herein below. Section R302 Design conditions. The outdoor and interior design conditions shall be as established in Tables 302.1 and 302.2 herein below. TABLE 302.1 Outdoor Design Conditions Elevation (feet) | 5344 Latitude (degrees north) | 40 TABLE 302.1 Outdoor Design Conditions (Cont'd) Winter | Heating 99% dry bulb (degrees) | 1 Cooling 1% dry bulb (degrees) | 94 Summer | Coincident wet bulb | 62 Design grains (50% RH) | -41 Daily range (DR) | High (H) Relative Humidity (winter and summer) | 50% TABLE 302.2 Interior Design Conditions Heating (degrees) | 70 Cooling (degrees) | 75 Heating Temperature Difference (HTD) | 69 Cooling Temperature Difference (CTD) | 16 Cooling Load Temperature Difference (CLTD) | 21.0 Altitude Correction Factor (ACF) | 0.84 Moisture Content | 68.2 Air Density | 0.063 Wind Velocity Values | Heating (mph) | 15 Cooling (mph) | 7.5 Solar Heat Gain Coefficient (SHGC): While not required per Table 402.1.1 of the IECC, the SHGC is still required data for Manual J. SHGC should be taken directly from sticker on glass. If not known, either use default as per Tables R303.1.3(1), (2), or (3) or equation SHGC = 0.87 x SC (shading coefficient) under A4-5 of Manual J. (C) Section R403.5.5 Demand responsive controls for heating and cooling systems is added as follows: R403.5.5 Demand responsive controls for heating and cooling systems. Electric heating and cooling systems for residential buildings shall be provided with demand responsive controls that meet the requirements of Appendix CI Section 101. (D) Amend Table R409.5.3.1 as follows: Table R409.5.3.1 EV Power Transfer Infrastructure Requirements: Building Type/Space Type | Level 2 EVSE Installed Spaces | Level 2 EV Ready Spaces | Level 2 EV Capable Spaces | Level 2 EV Capable Light Spaces Group R-3 and R-4 occupancies three stories or less in height above grade plane, with 15 or fewer parking spaces | 0 | 20% of spaces (not fewer than 2) | 0 | 0 Group R-3 and R-4 occupancies three stories or less in height above grade plane, with greater than 15 parking spaces | 2% of spaces | 8% of spaces | 10% of spaces | 10% of spaces Group R-2 occupancies three stories or less in height above grade plane with 10 or fewer parking spaces | 10% | 15% of spaces | 10% of spaces | 0 Group R-2 occupancies three stories or less in height above grade plane with greater than 10 parking spaces | 5% of spaces | 15% of spaces | 10% of spaces | 30% of spaces (E) Section R501.7 Programmable thermostat is added as follows: Section R501.7 Programmable thermostat. Alterations, additions, and changes of occupancy that involve replacing or expanding a heating or cooling system shall comply with section R403.1.1 Programmable thermostat. (F) Section R502.2.5 Additional energy efficiency credit requirements: Delete exception #1 below: 1. Additions that are less than 1,000 square feet (93sm) of conditioned floor area and increase the conditioned floor area by less than 25 per cent (G) Table C405.13.2 Energy Use Categories is amended to add a new line at the end: Electric vehicle charging Electric vehicle charging loads. (H) Amend Table C410.5.2.1 as follows: Table C410.5.2.1 EV Power Transfer Infrastructure Requirements Building Type/Space Type | Level 2 EVSE Installed Spaces | Level 2 EV Ready Spaces | Level 2 EV Capable Spaces | Level 2 EV Capable Light Spaces Commercial buildings, except for Group R-2 occupancies, with 15 or fewer parking spaces | 0 | 20% of spaces (not fewer than 2) | 0 | 0 Commercial buildings, except for Group R-2 occupancies, with greater than 15 parking spaces | 3% of spaces | 7% of spaces | 20% of spaces | 0 Group R-2 occupancies with 10 or fewer parking spaces | 10% | 15% of spaces | 10% of spaces | 0 Group R-2 occupancies with greater than 10 parking spaces | 5% of spaces | 15% of spaces | 10% of spaces | 30% of spaces (I) Section C502.3.3.1 Thermostatic controls is added as follows: C502.3.3.1 Thermostatic controls. Additions that involve replacing or expanding a heating or cooling system shall comply with section C403.4.1 Thermostatic controls. (J) Section C503.7 Thermostatic controls is added as follows: C503.7 Thermostatic controls. Alterations that involve replacing or expanding a heating or cooling system shall comply with section C403.4.1 Thermostatic controls.
(Ord. 1858 §1, 2008; Ord. 1926 §13, 2011; Ord. 2042 §9, 2017; Ord. No. 2115, 2-25-20; Ord. No. 2205, 3-7-23; Ord. No. 2295, § 4, 2-24-26)
Ask a question about Broomfield law
Corpus searches the Broomfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.