§ 15.06.030 — Amendments

Municipal Code of the Town of Castle Rock, Colorado (Codified through Ordinance No. 2026-014, enacted May 5, 2026 (Supp. No. 63)) · Castle Rock Municipal Code § 15.06.030

Corpus is an independent public-information project, not the official City of Castle Rock website. Stable reference: corpuslaw.us/code/940794d1-d79c-466a-8ad7-5ab19ea5857c

15.06.030 - Amendments.

The following amendments, additions and deletions are made to the International Residential Code: A. Section R101.1 Title is amended to read as follows: R101.1 Title. These provisions shall be known as the Residential Code for one- and two-family dwellings of the Town of Castle Rock and shall be cited as such and will be referred to herein as "this residential code." B. Section R105.2, Item 2, is amended to read as follows: Fences not over 6-feet (1829 mm) high. C. Section R202 Definitions is amended to add the following definitions: DECORATIVE COATINGS. A single coat of plaster, cementious or other approved material applied to a concrete or masonry surface for aesthetic purposes only. FLOOR AREA, GROSS. The floor area within the inside perimeter of the exterior walls of the building under consideration, exclusive of vent shafts and courts, without deduction for corridors, stairways, closets, the thickness of interior walls, columns or other features. The floor area of a building, or portion thereof, not provided with surrounding exterior walls shall be the usable area under the horizontal projection of the roof or floor above. This area could also include other exterior space intended to be used as part of the space to be occupied. The gross floor area shall not include shafts with no openings or interior courts. D. Section R109.1 Foundation Inspection is amended to add a new Section R109.1.1.1 to read as follows: R109.1.1.1. Foundation compliance. Inspections shall be performed by a professional engineer licensed in the State of Colorado or architect registered in the state of Colorado. A stamped written report shall be provided to the building official of the results for the inspection by a Colorado licensed professional engineer or architect registered in the state of Colorado. E. Section R301.2 Climatic and Geographic Design Criteria. Table R301.2 (1) is amended to read as follows: TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Loado* | Wind Speed (mph) | Seismic Design Categoryf | Subject to Damage From | Winter Design Tempe | Ice Barrier Under- layment Requiredh | Flood Hazardsg | Air Freezing Indexi | Mean Annual Tempj Speedd(mph) | Topographic effectsk | Special wind regioni | Windborne debris zone m | Weather- inga | Frost Line Depthb | Termitec 6000—6499 35 psf 6500—6999 40 psf | 115 mph Vult (Exposure is site specific) | No | No | No | B | Severe | 36" | Slight to moderate | 1°F | Yes | a.05/26/1988 b.03/16/2016 c.** | 867 | 48.1°F MANUAL J DESIGN CRITERIAn Elevation | Latitude | Winter heating | Summer cooling | Altitude correction factor | Indoor design temperature | Design temperature cooling | Heating temperature difference 6000-7000 feet | 39°N | -3° | 90° | .80 | 70° | 75° | 69° Cooling temperature difference | Wind velocity heating | Wind velocity cooling | Coincident wet bulb | Daily range | Winter humidity | Summer humidity | — 15° | 15 mph | 7.5 mph | 60° | High (H) | 40% | 50% | — *ground snow load = roof snow load, reductions for snow loads are not allowed **FIRMs: 08035C0166G, 08035C0167G, 08035C0168G, 08035C0169G, 08035C0186G, 08035C0187G, 08035C0188G, 08035C0189G, 08035C0191G, 08035C0192G, 08035C0193G, 08035C0282G, 08035C0284G, 08035C0301G, 08035C0302G, 08035C0303G, 08035C0304G, 08035C0306G Dated: 03/16/2016 08035C0283F, 08035C0292F, 08035C0310F Dated: 09/30/2005 For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(4). The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652. b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(5)A]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/ -percent values for winter from Appendix D of the International Plumbing Code. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. [Also see Figure R301.2(1).] f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) the panel numbers and dates of the currently effective FIRMs and FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended. h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. l. In accordance with Figure R301.2(5)A, where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. The jurisdiction shall fill in this section of the table using the Ground Snow Loads in Figure R301.2(6). F. Section R303 LIGHT, VENTILATION, HEATING is amended to read as follows: R303.1 Habitable rooms, is amended to add a new Exception 4 to read as follows: 4. The natural light requirement in basements of dwelling units or congregate residences may be reduced by 50%, except that sleeping rooms must meet the requirements of Section R310.1 G. Section R313 is deleted in its entirety. H. Section R315.3, amend Location to read as follows: Carbon monoxide alarms in dwelling units shall be installed outside of each separate sleeping area within fifteen feet of the entrance to each bedroom. Where a fuel-burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. I. Section R315.2.2, Exception 2, is deleted in its entirety. J. Section 507 Exterior Decks - Table R507.7, is amended to read as follows: TABLE R507.7 MAXIMUM JOIST SPACING FOR DECKING DECKING MATERIAL TYPE AND NOMINAL SIZE | MAXIMUM ON-CENTER JOIST SPACING Decking perpendicular to joist | Decking diagonal to joista 1¼-inch-thick-wood | 16 inches | 12 inches 2-inch-thick-wood | 24 inches | 16 inches Plastic composite | 12 inches | 12 inches For SI: 1 inch - 25.4 mm, 1 foot - 304.8 mm, 1 degree - 0.01745 rad. a. Maximum angle of 45 degrees from perpendicular for wood deck boards. K. Section R905.1.2 is amended to read as follows: R905.1.2 Ice barriers. As designed in Table R301.2(1), an ice barrier shall be installed on eaves and valleys for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles, and wood shakes. The ice barrier shall consist of not less than two layers of underlayment cemented together, or a self-adhering polymer modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building. On roofs with slope equal to or greater than eight units vertical in 12 units horizontal (67-percent slope), the ice barrier shall also be applied not less than 36 inches (914 mm) measured along the roof slope from the eave edge of the building. Exception: Detached accessory structures that do not contain conditioned floor area. L. Section R905, Requirements for Roof Coverings, is amended by adding a new Section R905.7.5.1 Wood shingle application, to read as follows: R905.7.5.1 Wood shingle application. All Class C and wood shingles shall be installed per Section 1505.7, Special purpose roofs, in the International Building Code. M. Section G2408.5 (305.8) Clearances to combustible construction is amended by the addition of a new Section G2408.5.1, to read as follows: G2408.5.1 Open-flame devices. Outdoor open-flame cooking devices and fixed -in-place appliances will not be allowed on any combustible surface or within 10-feet (3048 mm) of combustible construction. Exception: Where buildings, balconies and decks are protected by an automatic sprinkler system. N. Section G2413.3 is amended by the addition of Table G2413.2 to read as follows: TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES APPLIANCE | INPUT/BTU/H (Approx.) Space Heating Units Hydronic boiler Single family | 100,000 Multi-family, per unit | 60,000 Warm-air furnace Single family | 100,000 Multi-family, per unit | 60,000 Space and Water Heating Units Hydronic boiler Single family | 120,000 Multi-family, per unit | 75,000 Water Heating Appliances Water heater, automatic instantaneous Capacity at 2 gal/minute | 142,800 Capacity at 4 gal/minute | 285,000 Capacity at 6 gal/minute | 428,400 Water heater, automatic storage, 30- to 40-gal tank | 35,000 Water heater, automatic storage, 50-gal tank | 50,000 Water heater, domestic, circulating or side-arm | 35,000 Cooking Appliances Built-in oven or broiler unit, domestic | 25,000 Built-in top unit, domestic | 40,000 Range, free standing, domestic | 65,000 Other Appliances Barbeque | 40,000 Clothes dryer, Type 1 (domestic) | 35,000 Gas fireplace, direct-vent | 40,000 Gas light | 2,500 Gas log | 80,000 Refrigerator | 3,000 For SI: 1 British thermal unit per hour = 0.293 W, 1 gallon = 3.785 L, 1 gallon per minute - 3.785 L/m O. Section G2417.4.1, Test pressure, is amended to read in its entirety as follows: G2417.4.1 Test pressure. The test pressure to be used shall be no less than 1½ times the proposed maximum working pressure but not less than 10 psi. Ord. 2012-16 §1, 2012)

(Ord. No. 2019-012, § 2, 6-18-2019; Ord. No. 2015-06, § 2, 2-17-2015;

Ask a question about Castle Rock law

Corpus searches the Castle Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.