15.24.030 - Amendments.

The following amendments, additions and deletions are made to the International Existing Building Code: A. Section 101.1 Title is amended to read as follows: 101.1 Title. These regulations shall be known as the International Existing Building Code of the Town of Castle Rock, hereinafter referred to as "this code." B. Section 301.2 Additional codes is amended to read as follows: 301.2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall comply with the provisions for alterations, repairs, additions, and changes of occupancy or relocation, respectively, in this code and the International Energy Conservation Code, International Fire Code, International Fuel Gas Code, International Mechanical Code, International Plumbing Code, International Residential Code, International Swimming Pool and Spa Code and NFPA 70. C. Section 409 Moved Structures is amended to read as follows: SECTION 409 - MOVED STRUCTURES 409.1 Conformance. Structures moved into or within the jurisdiction shall comply with the provisions of this Code for new buildings and structures. Exception: Manufactured homes which are not certified by the Colorado Division of Housing or are not otherwise approved as meeting the minimum requirements of the International Building Code, International Plumbing Code, International Mechanical Code, and National Electric Code, shall be installed and used in accordance with Section 409.2 and other pertinent laws and regulations. 409.2 Manufactured housing. 409.2.1 General. No manufactured home shall be installed or placed upon a site or manufactured home space unless a permit has first been obtained from the Chief Building Official and the manufactured home bears a label or has other approved documentation certifying that the manufactured home was constructed in accordance with NFPA 501B/ANSI A 119.1 (1973, 1974 and 1975 Editions) or the Federal Manufactured Home Construction and Safety Standards Act (42 U.S.C. §5401, et seq., as amended). Exception: When inspected and approved on an individual basis by the Chief Building Official, manufactured housing constructed prior to 1973 and not certified to meet the standards listed in Section 409.2.1 above may be installed on manufactured home spaces in a manufactured home park, subject to the following requirements: 1. Structural condition. The manufactured home is, as best as can be determined by inspection, structural observation by an approved special inspector, or other reasonable means, in a safe, sound, physical and structural condition. 2. Exit facilities. The manufactured home shall be equipped with two operational exit doors. 3. Smoke detectors. The manufactured home shall have operable, approved smoke detectors installed in accordance with the requirements of Section R314.3.1 of the International Residential Code for alterations to buildings. 4. Electrical. All electrical wiring and distribution equipment within the manufactured home shall be, as best as can be determined by inspection, in safe working condition and, at a minimum, in conformance with nationally recognized standards in effect at the time of construction of the manufactured home. 5. Mechanical. All fuel-burning appliances within the manufactured home, including furnaces, water heaters and solid-fuel burning fireplaces or fireplace stoves, shall be, as best can be determined by inspection, in safe working condition, including the provision of or the condition of shutoff valves, flexible connectors, combustion air, clearances to combustible materials, vents and chimneys. 6. Plumbing. All plumbing fixtures, drainage piping and water piping within the manufactured home shall be, as best as can be determined by inspection, in safe operating condition. 409.2.2 Installation standards. Manufactured homes shall be installed in accordance with Resolution 20 of the State Housing Board, "The Colorado Installation and Set-up Standards for Manufactured Housing," which resolution adopts by reference with amendments, NCSBCS A225.1 (ANSI A225.1-1987), the NCSBCS Standard for Manufactured Home Installations. Wind anchoring equipment (ties) shall be in accordance with the installation standards, including wind load requirements of the Town of Castle Rock. 409.2.3 Manufactured homes on permanent foundations. Manufactured homes which are not less than 24-feet in width and 36-feet in length, and which have a brick, wood or cosmetically equivalent exterior siding and a pitched roof, and are not otherwise in accordance with §30-28-115(3)(a), C.R.S., as amended, may be installed outside of manufactured home parks if installed on engineering permanent foundations and if the installation is otherwise in accordance with all applicable site installation requirements of this Code for dwellings. In addition, such homes shall be certified as having roof structures sufficient to support snow loads of the Town of Castle Rock at the building site and shall also be certified as meeting the minimum requirements of the Energy Code. 409.2.4 Accessory buildings and structures. Accessory structures, including porches, stairways, landings, storage structures, awnings, carports, cabanas, ramadas and similar structures shall be constructed in accordance with the Building Code and the applicable requirements of the Colorado Installation and Set-up Standards for Manufactured Housing. 409.2.4 Replacement furnaces, water heaters and wood stoves. The installation or replacement of furnaces, unit heaters, water heaters and solid fuel-burning appliances shall be in accordance with the federal Manufactured Home Construction and Safety Standards Act.

(Ord. No. 2019-012, § 11, 6-18-2019; Ord. 2012-16 §1, 2012)

Ask a question about Castle Rock law

Corpus searches the Castle Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.