§ 17.60.080 — Operational standards
Municipal Code of the Town of Castle Rock, Colorado (Codified through Ordinance No. 2026-014, enacted May 5, 2026 (Supp. No. 63)) · Castle Rock Municipal Code § 17.60.080
Corpus is an independent public-information project, not the official City of Castle Rock website. Stable reference: corpuslaw.us/code/b4971474-2bc7-4d98-bd49-abc9d002460e
17.60.080 - Operational standards.
A. Federal Requirements. All WCFs shall meet the current standards and regulations of the FAA, the FCC and any other agency of the federal government with the authority to regulate WCFs. If such standards and regulations are changed, then the owners of the WCF governed by this Chapter shall bring such facility into compliance with such revised standards and regulations within the time period mandated by the controlling federal agency. To this effect, all applications for WCFs shall include, without limitation, the following: 1. A radio frequency emissions letter. 2. A signal interference letter. Failure to meet such revised standards and regulations shall constitute grounds for the removal of the WCF at the owner's expense. B. Agreements and Legal Access. For WCFs in the public right-of-way, the applicant shall execute a license agreement with the Town granting a non-exclusive license to use the public right-of-way. Attachment of a WCF to Town-owned poles and vertical assets in the right-of-way shall require a pole attachment agreement with the Town. Attachment of WCFs on other existing street light poles, or similar poles in the right-of-way shall require written evidence of a license, or other legal right or approval. For WCFs on public property, the applicant shall execute a lease agreement with the Town. For WCFs on private property, the applicant must warrant and represent that it has the written agreement of the owner of the property which is the subject of the application for legal access to and from the WCF and the applicant must also warrant and represent that it will have legal access to the utilities to operate and maintain the WCF. C. Structural Integrity. To ensure the structural integrity of WCFs, the owner of a WCF shall ensure that it is maintained in compliance with standards contained in applicable local building and safety codes. If upon inspection, the Town concludes that a WCF fails to comply with such codes and constitutes a danger to persons, property or the environment, then, upon written notice being provided to the owner of the WCF, the owner shall have thirty (30) days from the date of notice to bring such WCF into compliance. Upon good cause shown by the owner, the Town may extend such compliance period not to exceed ninety (90) days from the date of said notice. If the owner fails to bring such WCF into compliance within said time period, the Town may remove such WCF at the owner's expense. If the WCF poses an immediate danger to persons, property, or the environment the Town may cause for the WCF to be immediately deactivated or removed. The Town will provide notice of such immediate deactivation or removal to the applicant as soon as practicable. D. Noise. Noise generated on the site must not exceed the levels permitted pursuant to Chapter 9.16 of the Code. E. Abandonment and Removal. If a WCF has not been in use for a period of ninety (90) days, the owner of the WCF shall notify the Town of the non-use and shall indicate whether re-use is expected within the ensuing ninety (90) days. Any WCF that is not operated for a continuous period of one hundred eighty (180) days shall be considered abandoned. The Town, in its sole discretion, may require an abandoned WCF to be removed. The owner of such WCF shall remove the same within thirty (30) days of written notice being provided by the Town. If such WCF is not removed within said thirty (30) days, the Town may remove it at the owner's expense and any approved permits for the WCF shall be deemed to have expired. The owner of the WCF and the property owner shall provide an affidavit acknowledging that it is responsible for the removal of a WCF that is abandoned. F. Applicable Town Standards. Each WCF installed in the right-of-way including on Town-owned poles within the right-of-way shall meet criteria and standards described in the Town of Castle Rock Transportation Design Criteria Manual and any other applicable technical criteria. G. Site Maintenance. WCFs shall be maintained in good working condition and to the standards established at the time of application approval and remain free from trash, debris, litter, graffiti, and other forms of vandalism. Any damage shall be repaired as soon as practicable, and in no instance more than ten (10) business days from the time of notification by the Town or after discovery by the owner or operator of the site. Notwithstanding the foregoing, any graffiti on WCFs located in public right-of-way or on other public property may be removed by the Town at its discretion, but not without prior notice to the owner or operator of the site with an opportunity to remove the graffiti. The owner and/or operator of the WCF shall pay all costs of such removal from the WCF within thirty (30) days after receipt of an invoice from the Town. H. Compliance Report. Upon request by the Town, the applicant shall provide a compliance report within forty-five (45) days after installation of a WCF, demonstrating that, as installed and in operation, the WCF complies with all conditions of approval, applicable Code requirements, and standard regulations.
(Ord. No. 2018-023, § 1, 6-19-2018)
Ask a question about Castle Rock law
Corpus searches the Castle Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.