For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-3-801 — Exceptions to Setback Standards

Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-3-801

Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/9ba5b0a1-90dd-4555-92d5-d2566182938c

Sec. 12-3-801. - Exceptions to Setback Standards.

A. Generally. Table 12-3-801, Permitted Projections into Required Nonresidential and Mixed-Use Setbacks, sets out projections that may be located outside of required setbacks (between the setback lines and the lot lines). B. Interpretation of Table 12-3-801, Permitted Projections into Required Nonresidential and Mixed-Use Setbacks. 1. Measurements in the table are taken from the applicable setback line (A); from the lot line (B); or into the right-of-way (C). See Figure 12-3-801, Illustrative Measurement of Nonresidential Encroachments. 2. If a measurement is indicated for "(A) From Setback Line Toward Lot Line" and "(B) From Lot Line Toward Lot Interior," then the measurement that results in the larger distance from the lot line to the encroachment controls. 3. If a measurement is indicated for "(A) From Setback Line Toward Lot Line" and "(C) Into Right-of-Way," then the measurement that allows the smallest encroachment into the right-of-way controls. Table 12-3-801 Permitted Projections into Required Nonresidential and Mixed-Use Setbacks Location/Projection | Permitted Encroachments (A) From Setback Line Toward Lot Line | (B) From Lot Line Toward Lot Interior | (C) Into Right-of-Way 1 All Setbacks Awnings and canopies without supports that extend to ground, not less than 8 feet above sidewalk, and no interference with traffic flow | 8 ft. | 2 ft. | 8 ft., subject to subsection C., below Steps, 4 feet or less above grade, which are necessary for access to a permitted building | 5 ft. | 0 ft. | Not Allowed Chimneys | 2 ft. | 1 ft. | Not Allowed Arbors, pergolas, and trellises | NA 2 | 3 ft. | Not Allowed Flagpoles | NA | 5 ft. | Not Allowed Fences, garden walls, and hedges | NA | See Section 12-3-802 | Not Allowed Driveways, except at points of access | NA | 10 ft. | Not Allowed Front Setbacks Overhanging eaves and gutters | 2.5 ft. | 0 ft. | 1 ft., subject to subsection C., below Patios; Decks that are less than 3 feet above grade | 10 ft. | 5 ft., or width of bufferyard, whichever is greater | Not Allowed Enclosed vestibule, 150 square feet or less in floor area encroaching | 5 ft. | 3 ft. | Not Allowed Side Setbacks Overhanging eaves and gutters | 2.5 ft. | 1 ft. | 1 ft., subject to subsection C., below Air conditioning units | 5 ft., if screened from view by a garden wall or hedge that is one foot taller than the equipment | 2.5 ft., if screened from view by a garden wall or hedge that is one foot taller than the equipment | Not Allowed Patios; Decks, less than 3 feet above grade | NA | 3 ft.; but 0 ft. if the adjacent lot or parcel is permanent open space | Not Allowed Decks, 3 feet or more above grade | 6 ft. | 6 ft.; but 0 ft. if the adjacent lot or parcel is permanent open space | Not Allowed Rear Setbacks Overhanging eaves and gutters | 2.5 ft. | 1 ft. | 1 ft., subject to subsection C., below Air Conditioning Units | 5 ft., if screened from view by a garden wall or hedge that is one foot taller than the equipment | 5 ft., if screened from view by a garden wall or hedge that is one foot taller than the equipment | Not Allowed Patios; Decks, less than 3 feet above grade | NA | 3 ft. | Not Allowed Decks, 3 feet or more above grade | 12 ft. | 10 ft. | Not Allowed TABLE NOTES: 1 Encroachments and structures listed in this column are subject to and conditioned upon compliance with subsection C. of this Section. If compliance is not demonstrated, then the standards for (B) From Lot Line shall be applied. 2 NA means "not applicable," in that the limits from the other columns are sufficient to control the location of the encroachment. Figure 12-3-801 Illustrative Measurement of Nonresidential Encroachments [image omitted; see the official code] C. Right-of-Way Encroachments. Encroachment into the public right-of-way is generally not allowed, but may be permitted if it is demonstrated that the encroachment: 1. Is attached to a building that is located in a UC district, AC district, or a mixed-use building located in traditional neighborhood development; 2. Is, regardless of the permitted encroachment distance specified in Table 12-3-801, Permitted Projections into Required Nonresidential and Mixed-Use Setbacks, limited to not closer than two feet to the back of the street curb or the inside edge of a tree lawn, whichever is less of an encroachment; 3. Does not encroach on arterial rights-of-way; 4. Is constructed and situated in a manner that does not obstruct pedestrian or vehicular traffic or constitute a safety hazard; and 5. Is subject to a revocable license to encroach upon the public right-of-way. D. Other Limitations. No projection shall encroach into: 1. Separately owned property, unless a recorded document provides for access to and maintenance of the projection; or 2. Utility easements, unless the design of the improvement and a recorded agreement allows access to the utility and allows the utility provider or the City to efficiently remove the encroachment at the property owner's expense.

(Ord. 2021-O-13 §20)

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.