§ 12-4-207 — Nonresidential Design Standards
Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-4-207
Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/c162197c-63d7-4937-98ee-b16cef1ab7bd
Sec. 12-4-207. - Nonresidential Design Standards.
A. Applicability. This Section shall apply to all nonresidential new construction that requires a building permit; and to expansions or enlargements equal to 50 percent or more of existing floor area in a single nonresidential building, or addition of new floors, including any cumulative expansions or enlargements that meet this threshold based on the floor area in place as of August 6, 2007. B. Exemptions. The following are exempt from the requirements of this Section: 1. Routine maintenance and repair; 2. Interior remodeling of existing buildings; 3. Projects within an area covered by an approved final development plan ("FDP") or master development plan ("MDP"), so long as no amendment (other than an administrative amendment) to that plan is necessary; and 4. Projects for which a complete development application has been submitted prior to August 6, 2007. C. Building Design. 1. Four-sided Design. a. Each building shall incorporate a similar level of quality and architectural features and treatments on all sides subject to public view or adjacent properties, not including properties across alleys. b. Display a similar level of quality and architectural interest. c. Blank walls void of architectural details or other variation are prohibited. d. Four-sided design shall be achieved by meeting the requirements in the following subsections below. Figure 12-4-207A Four-Sided Design [image omitted; see the official code] 2. Building Mass and Form. a. A single, large, dominant building mass is prohibited. b. Buildings shall be designed to reduce apparent mass by dividing façades into a series of smaller components no wider than sixty feet (60') in dimension. c. Buildings shall incorporate a combination of horizontal and vertical expressions with the goal of reducing bulk mass and creating a lively articulated façade. d. Buildings shall include intermediate forms (such as corner elements, protruded or recessed bays, or similarly expressed structural elements), to transition between higher and lower buildings. e. Form the building edges that define and contain the street space to reinforce pedestrian activity and create a sense of place. Figure 12-4-207B Building Mass and Form [image omitted; see the official code] 3. Architectural Scaling Elements. Architectural Scaling Elements. See Figure 12-4-207C, Illustrative Architectural Scaling Elements. Figure 12-4-207C Illustrative Architectural Scaling Elements [image omitted; see the official code] a. Articulated changes in horizontal and vertical plane shall be consistent in texture, material and/or color. b. Both horizontal and vertical architectural scaling patterns shall be used. c. Architectural scaling shall provide visual interest at pedestrian levels, reduce the massive appearance of large buildings and use architectural features to reflect the local character. d. Architectural scaling shall have a horizontal expression that promotes pedestrian scale, sun shading, material change, or plane change. e. Building corners shall be given extra attention and shall achieve a higher level of architecture, and activation of the street edge through the use of human scaled facades and activation of the street through transparency. f. Building masses shall provide richness and diversity that exhibits Human Scale Design and encourages street life through (a) use of variation of materials and/or colors, (b) visual interest created through texture, finish and detailing, and a (c) minimum of 2 of the following façade articulation methods to avoid long, monotonous walls: i. Application of materials in units, panels or modules that produce shadow lines to convey a sense of scale. ii. Expression of structural or architectural bays through a consistent, articulated bay rhythm. iii. Glazing with strongly expressed mullions. iv. Awnings or canopies. v. Balconies and terraces, where appropriate for building function. g. Components shall be distinguished from one another through two (2) or more of the following: i. No individual component shall have a horizontal length of more than 60 feet; ii. Variations in roof form or variations in roof height of two feet or more; iii. Changes in wall plane of one foot or more; iv. Variations in the arrangement of windows; and/or v. Recognizable changes in texture, material, or surface colors; or on the façade facing the principal street. 4. Entrances. Buildings shall feature visually prominent entrances on the façade facing the principal street. A combination of at least two or more of the following techniques shall be used: a. Canopy, portico, archway, arcade, or similar projection that provides architectural interest and protection for pedestrians; b. Prominent tower, dome or spire; c. Peaked roof; d. Projecting or recessed entry; e. Outdoor features, such as seat walls, landscaping with seasonal color, or permanent landscape planters with integrated benches; or f. Other comparable techniques. 5. Exterior Building Wall Materials. a. Untextured tilt-up concrete panels are prohibited for use on exterior building walls. b. Not more than twenty-five percent (25%) of the total lateral surface area of a Building's exterior facade (or the sum of areas of all the exterior walls) may be comprised of Corrugated Metal. c. Not more than twenty-five percent (25%) of the total lateral surface area of a Building's exterior facade (or the sum of areas of all the exterior walls) may be comprised of mirrored or reflective glass. D. Pedestrian Amenities. Ground-floor façades that face public streets or other public areas (e.g., outdoor gathering spaces, parks or open space, parking areas) shall incorporate pedestrian-oriented design features along no less than 60 percent of their horizontal length. Pedestrian-oriented design features include shaded sidewalks, arcades, entryways, and awnings. Display windows that meet the transparency (glazing) requirements of subsection C., above may be used to meet this requirement. E. Mechanical Equipment Screening. All rooftop and grade-level mechanical equipment shall be screened from grade-level view. Soft water tanks, gas meters, venting, heating and air conditioning units, and electrical meters shall also be screened from public view. Screening shall be part of the articulation of the building and integrated into the building design. All vents greater than eight inches in diameter shall also be screened. Screens shall be at least as high as the equipment they hide, and shall be of a color and material matching or compatible with the dominant colors and materials found on the façades of the primary building. See Figure 12-4-207E, Equipment Screening. Figure 12-4-207E Equipment Screening [image omitted; see the official code] F. Pedestrian and Bicycle Connections. 1. Generally. All development shall provide a network of on-site pedestrian walkways to and between the following areas: a. Public entrances to each building on the site, including pad site buildings; b. Parking areas; c. Sidewalks or walkways on adjacent properties that extend to the boundaries shared with the subject development; d. Adjacent public transit station areas, transit stops, park and ride facilities, or other transit facilities. For example, sidewalks adjacent to a public street shall be connected to all publicly used entrances, all off-street parking areas, all sidewalks or walkways on adjacent properties that extend to the boundaries shared with the subject development, and any transit-related facilities as described above. 2. Bicycle Access. Bicycle access from the development site shall be provided to any existing or designated sidewalks, bike paths, or bike lanes located adjacent to the development. 3. Connections. Connections shall be made at points necessary to provide direct pedestrian and bicycle travel from the development to major pedestrian destinations located within the adjacent neighborhood(s). In order to provide direct pedestrian connections to these adjacent destinations, the City may require additional sidewalks, walkways, or bike paths not associated with a street, or the extension of a sidewalk from the end of a cul-de-sac to another street or walkway. Major pedestrian destinations include, but are not limited to, residential subdivisions, schools, parks, open space, recreational facilities, neighborhood shopping, employment, recreation or community centers, public or civic uses, and institutional uses such as religious assembly. 4. Identification. Pedestrian walkways and crosswalks shall be identified through the use of one or more of the following methods: a. Changing paving material, patterns, or paving color; b. Changing paving height; c. Decorative bollards; d. Painted crosswalks; or e. Raised median walkways with landscaped buffers.
(Ord. 2024-O-05 §22; Ord. 2026-O-07 §§3, 4)
Ask a question about Centennial law
Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.
