For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-5-102 — Application of Article

Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-5-102

Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/7fe2e449-0f07-4742-8556-951aa28705e6

Sec. 12-5-102. - Application of Article.

A. Generally. This Section describes how the sections of Article 5, Parking and Loading, are applied, and how they relate to other provisions of this LDC. B. Number of Required Parking and Loading Spaces. The number of parking and loading spaces that must be provided for a proposed development is calculated as provided in Division 5-2, Parking and Loading Calculations. Section 12-5-201, Calculation of Required Parking Spaces, establishes the methodology for calculating the number of required parking spaces, including measurement of independent variables and application of available credits and reductions that are allowed by Section 12-5-205, Parking Credits and Reductions, and Section 12-5-206, Shared Parking. C. Bicycle Parking. Bicycle parking is required as set out in Section 12-5-207, Bicycle Parking. D. Stacking Design and Analysis. Drive-through lanes shall comply with the following design and stacking analysis requirements as well as any additional applicable requirements pursuant to the Roadway Design & Constructions Manual: 1. Design a. Businesses that provide drive-through facilities are required to provide spaces for vehicles waiting in line. Required stacking spaces shall be a minimum nine (9) feet wide and twenty (20) feet in length and shall not be counted as required on-site parking spaces. Stacking spaces shall be located to prevent any vehicles from extending onto the public right-of-way, or interfering with any pedestrian circulation, traffic maneuvering, or other parking space areas. b. Each drive-through lane shall be a separate lane from the circulation routes and lanes necessary for ingress to, or egress from, the property or access to any off-street parking spaces. Each such lane shall be striped, marked or otherwise distinctively delineated. c. The entrance of a drive-through lane shall be located not closer than 25 feet from the right-of-way line of any adjacent public street providing direct access to the lane. d. Drive-through ordering systems shall be located to allow a minimum of four (4) cars to queue behind the ordering vehicle to prevent vehicles from stacking in the drive aisle of the parking lot. See Figure 12-4-202A, Illustrative Drive-Through Layout. e. If drive-through operations will include in person staff taking customer orders in the drive-through lanes, sufficient, marked walking space shall be provided in an amount of 3 extra feet per lane to promote staff safety. 2. Stacking analysis a. The design of all drive-through lanes shall be subject to the approval of the Community Development Director. Design and approval shall be based upon information contained in a traffic engineering study prepared by an independent traffic engineer licensed by the State of Colorado, or such other study as approved by the Community Development Director, and provided to the City by the developer, at such developer's sole expense, at the time of application for such use. b. The final stacking analysis shall be submitted to the Director in writing which shall include recommendations of the length and number of stacking lanes to be associated with the proposed business in order to: i. Avoid or mitigate interference with parking spaces and drive aisles associated with the proposed business; ii. Avoid or mitigate stacking of vehicles in conflict with entry and exit points of the proposed business; and iii. Prevent unauthorized stacking of vehicles onto neighboring businesses, or private or public access lands or roads. c. The study required by the provisions of this subsection shall contain and address the following factors: i. Nature of the product or service being offered, including peaking characteristics on weekdays and weekends; ii. Method by which the order, request, sale or service is processed; iii. Time required to serve a typical customer; iv. Arrival rate of customers; v. Time period over which customers will arrive at stated rate; vi. Anticipated length of queuing; vii. Discussion of ambient circulation and parking, either proposed or existing; viii. Location of storage areas with respect to parking spaces or circulation aisles; ix. Discussion of potential blockages due to queue; and x. Mitigation measures to address peak stacking demand. xi. The study shall include a scale drawing delineating all parking spaces, circulation facilities, driveways and the nearest public street. xii. Each such lane shall be designed to prevent circulation congestion, both on-site and on public and private streets and accessways. xiii. The study shall include an analysis of at least five comparable uses. d. The City may rely upon the stacking analysis or may request additional information or analysis, including, but not limited to: alternative or new data points, or consideration of additional or alternative factors related to comparability or peak demand, as supported by sound engineering principles. e. Stacking shall not overflow onto rights-of-way. f. Stacking shall not generally overflow onto adjacent properties. To the extent the designated stacking regularly exceeds the lot on which the Drive-Through is situated, the City shall require cross access easements or other form of recorded consent from adjacent or impacted property owners. Stacking mitigation required by the City either at the time of development or during the operation of a drive-through may include, but shall not be limited to, requiring consent for stacking to occur off of the site of the Restaurant, Drive-Through use and dedicated in-person management for overflow stacking onto adjacent lots. E. Design of Parking and Loading Areas. The size and configuration of parking and loading spaces shall be as set out in Division 5-3, Parking and Loading Design and the Roadway Design and Construction Standards Manual. Parking and loading areas may also be subject to supplemental nonresidential and mixed-use standards in Division 3-8, Supplemental Nonresidential and Mixed-Use Development Standards. F. Surfacing, Use, and Maintenance of Parking and Loading Areas. Standards for the surfacing, use, and maintenance of parking and loading areas are set out in Division 5-4, Use and Maintenance of Parking and Loading Areas. Additional design standards are set out in Division 3-8, Supplemental Nonresidential and Mixed-Use Development Standards. Standards that apply to temporary uses in parking and loading areas are set out in Article 2, Districts and Use Standards. G. Truck Routing. Some uses that involve heavy truck traffic require a truck routing plan as part of the application for development approval. The standards for such plans are set out in Division 5-5, Truck Routing Plans.

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.