§ 12-7-304 — Provisions for Flood Hazard Reduction (Standards)
Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 12-7-304
Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/26c9dc18-3f2e-441a-88fb-7874d0d9b952
Sec. 12-7-304. - Provisions for Flood Hazard Reduction (Standards).
A. Generally. In all floodplains, the standards of this Section are required to be met. B. Proposed Structures in the Floodplain. 1. New Construction. New construction or installation of residential or non-residential structures shall be prohibited. 2. Other Development. All other development in floodplains shall be prohibited unless shown to the satisfaction of the Floodplain Administrator through a floodplain development permit that the proposed development (as defined in Article 16) does not adversely affect the efficiency of, or unduly restrict the capacity of, the channels or floodplains of the mainstream or any tributaries to the mainstream, drainage ditches, or any other drainage facilities or systems. 3. Conditions of Approval of Floodplain Development Permit. The Floodplain Administrator may impose conditions of approval on Floodplain Development Permits to achieve compliance with the provision for flood hazard reduction standards, which conditions may include modification of proposed systems and facilities and imposition of operational controls and limitations on periods and conditions of use and operation. Additionally, a map revision process may be required prior to permit approval. C. Existing Structures in Floodplains. 1. Use of Floodplains. All uses of property in a floodplain shall comply with applicable floodplain regulations contained in this LDC. It is the intent of the City that no new construction of structures be constructed in a floodplain, and that all such existing legal nonconforming structures either be removed upon obsolescence or be improved to meet substantial improvement criteria set forth in Subsection C(2), Substantial Improvements, below. 2. Substantial Improvements. Substantial improvements (including improvements due to damage) of existing structures are permitted in the flood fringe but not in the floodway, provided such substantial improvements meet the freeboard criteria in Subsection C(3), Construction Standards and do not increase the footprint of the structure. 3. Construction Standards. All improvements to existing structures in the floodplain shall adhere to the following: a. Residential Construction. Substantial improvements to any residential structure in the floodplain shall have the lowest floor elevated to or above the minimum freeboard requirement of two (2) feet or highest adjacent grade plus two (2) feet above the depth in shallow flooding areas (AO and AH Zones). A registered Colorado Professional Engineer, architect, or land surveyor shall submit certification (Elevation Certificate) to the Floodplain Administrator and that the standard of Section 12-14-206, Floodplain Development Permit, have been satisfied. b. Nonresidential Construction. Substantial improvement of any commercial, industrial or other nonresidential structure shall either: i. Meet the minimum freeboard of two (2) feet or highest adjacent grade plus two (2) feet above the depth in shallow flooding areas (AO and AH Zones). A registered Colorado Professional Engineer, architect, or land surveyor shall submit certification (Elevation Certificate) to the Floodplain Administrator and that the standard of Section 12-14-206, Floodplain Development Permit, have been satisfied; or ii. Together with attendant utility and sanitary facilities, shall: a. Be flood-proofed so that below the base flood level plus two (2) feet of freeboard the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; c. Be certified by a registered Colorado Professional Engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of this Section. The Floodplain Administrator shall keep records of these certifications (Floodproofing Certification) pursuant to Section 12-13-103, Floodplain Administrator; and d. In shallow flooding areas (Zone AH or AO) have adequate drainage paths around the structure to guide flood waters around and away from the structure. c. Construction Materials and Methods. i. All substantial and non-substantial improvements shall be constructed with materials and utility equipment that are resistant to flood damage. ii. All substantial and non-substantial improvements shall be constructed using methods and practices that minimize flood damage. iii. All substantial and non-substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating with the components during conditions of flooding. d. Openings in enclosures below the Lowest Floor. For all substantial improvements, fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must either be certified by a registered Colorado Professional Engineer or architect or must meet or exceed the following minimum criteria: i. A minimum of two openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided; ii. The bottom of all openings shall be no higher than one (1) foot above grade; iii. Openings may be equipped with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwater. 4. Anchoring. a. Foundations shall be designed or engineered to be anchored to resist flotation, collapse or lateral movement and be capable of resisting the hydrostatic and hydrodynamic loads. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to any applicable State and/or local anchoring requirements for resisting wind forces. In addition, the following specific requirements shall be met: i. Over-the-top ties must be provided at each of the four (4) corners of the manufactured home, with two (2) additional ties per side at intermediate locations, with manufactured homes less than fifty (50) feet long requiring one additional tie per side; ii. Frame ties must be provided at each corner of the home, with five (5) additional ties per side at intermediate points, with manufactured homes less than fifty (50) feet long requiring four (4) additional ties per side; iii. All components of the anchoring system must be capable of carrying a force of four thousand eight hundred (4,800) pounds; and D. Critical Facilities. 1. Protection for critical facilities. a. New construction of critical facilities shall be located outside the floodplain. b. Change of use of a structure to a critical facility or substantial improvement of an existing critical facility in the floodplain shall include elevation of the lowest floor or flood-proofing of the structure (non-residential construction), together with attendant utility and sanitary facilities, to at least two (2) feet above the Base Flood Elevation. Additionally, no increase in the footprint of the existing facility shall be allowed. 2. Ingress and egress for critical facilities. New construction of critical facilities, change of use of a structure to a critical facility, or substantial improvements of existing critical facilities shall, when practicable as determined by the City, have continuous non-inundated access (ingress and egress for evacuation and emergency services) during a 100-year flood event. E. Freeboard. A minimum clearance, or freeboard shall, be provided between the floodplain or adjacent to the floodplain or shallow flooding area and structures and other applicable facilities which may be impacted by the base flood. Freeboard is required to allow for uncertainty in the floodplain modeling, changes to drainageway (i.e., increased invert due to sedimentation), upstream development and to provide an additional factor of safety (buffer) for structures and facilities which would experience damages or hazards during inundation. 1. The City requires a minimum of two (2) feet of freeboard between the 100-year water surface elevation and the lowest floor elevation of all substantially improved structures in the floodplain or adjacent properties to the floodplain. 2. For facilities which are not structures such as roadways, utility cabinets, parks and trail improvements, a minimum of one (1) foot of freeboard may be required where there are detrimental impacts to the floodplain as determined by the Floodplain Administrator. 3. Shallow flooding areas (AO and AH Zones) or adjacent properties shall have the lowest floor elevated two (2) feet above the highest adjacent grade or two (2) feet above the depth number specified in feet on the community's FIRM, assuming a depth of at least two (2) feet if no depth is specified on the FIRM. F. Utilities. 1. All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system. 2. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharge from the systems into floodwaters. 3. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. G. Floodways. Construction in the floodway as allowed per Section 12-7-202 C and D, Performance Standards for Use of Floodplains, shall be subject to the following requirements: 1. Development is prohibited, including fill, new construction, and other development unless certification by a registered Colorado Professional Engineer is provided demonstrating that encroachment shall not result in any increase in flood levels (no rise) during the occurrence of the base flood, or otherwise alter the floodway in a manner which will constrict the channel or increase erosion potential unless a FEMA approved CLOMR that addresses the 44 CFR Part 65, Section 12 requirements or City approved Floodplain Modification Study are obtained. 2. If the requirements of subsection G.1. above are satisfied, all new construction shall comply with all applicable flood hazard reduction provisions of this Section. 3. For all floodplains and special flood hazard areas that do not have a regulatory floodway designated, development is prohibited unless there is a City approved Floodplain Modification Study or FEMA approved CLOMR. 4. For LOMRs on special flood hazard areas where the effective FIRM shows a one (1.0) foot floodway, the one-half (0.5) foot floodway will not be required until the entire drainageway is remapped at which time the revised map will show a one-half (0.5) foot floodway. H. Flood Fringe Development. Encroachment in the flood fringe is only allowed for approved uses listed in Section 12-7-202, Use of Floodplains. When considering requests involving flood fringe development, the Floodplain Administrator shall consider, at a minimum, the following: 1. Flood fringe filling. Filling will not be allowed for purposes of obtaining a CLOMR-F/LOMR-F or similar (i.e., as a way to remove a property from the floodplain) for future site development. 2. Impacts to Adjacent Properties. If the development creates a rise in the Base Flood Elevation on properties other than that of the applicant and the applicant has obtained a City approved Floodplain Modification Study or FEMA approved CLOMR, the applicant will be required to obtain floodplain easements for the additional floodplain property. 3. Channel Hydraulics and Design. If the development creates a significantly narrow channel, with steep side slopes and undesirable velocities, the City may require mitigating channel improvements, or not support the flood fringe development. 4. Channel Aesthetics and Land Use. If the encroachment significantly impacts the aesthetics of the natural drainageway, and the resulting channel improvements create a drainageway that is not deemed compatible with the surrounding land uses, the City may not support the flood fringe development. 5. Flood Fringe and Floodway Volume. If the development does not maintain equivalent flood fringe and floodway volumes, the City may not support the proposal. 6. Cumulative Effect. The one-half (0.5) foot floodway is cumulative, and therefore all proposals considering development in the fringe, must consider the total cumulative impact, based on historical and future encroachment on both sides of the drainageway. 7. Floodplain Modification Study or CLOMR. When flood fringe development is allowed, a floodplain modification study, or CLOMR consistent with the scope of work shall be provided. 8. LOMR-F. A Floodplain Development Permit shall not be issued for the construction of a new structure, redevelopment (substantial improvements) of an existing structure or addition to an existing structure on a property removed from the floodplain by issuance of a FEMA Letter of Map Revision Based on Fill (LOMR-F), where the lowest floor elevation is placed below the Base Flood Elevation (BFE). For this situation, the lowest floor elevation must be two (2) feet above the BFE (freeboard) that existed prior to the placement of fill, to receive an approved Floodplain Development Permit. I. Subdivision Proposals. The following shall apply to all subdivision applications on land in or adjacent to floodplain areas. 1. Minimize Flood Damage. All subdivision applications including the placement of manufactured home parks and subdivisions shall be consistent with the need to minimize flood damage. 2. Floodplain Development Permit. All subdivision applications shall meet Floodplain Development Permit requirement of Section 12-14-206, Floodplain Development Permit. 3. Protection of Utilities. All subdivision applications shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. 4. Drainage. All subdivisions shall have adequate drainage provided to reduce exposure to flood hazards. 5. Base Flood. The applicant shall be responsible for generating any base flood elevation data and survey data requested by the Floodplain Administrator relating to the site and proposed development. In cases where there is conflicting base flood elevation data, the data which is most protective of flood hazard areas and which restricts development will be used. 6. Floodplain Areas. Floodplain boundaries must be considered in subdivision layout, where applicable. When the floodplain boundary accurately represents the proposed floodplain limits, lots can be platted as discussed in the previous sections. There are many cases, however, where the SFHA or mapped floodplain is much wider than the actual or proposed floodplain. This situation frequently arises in locations where the SFHA or mapped floodplain was delineated using approximate methods or where improvements are proposed to confine the floodplain. In this case, platted lots must be outside of the SFHA or mapped floodplain or the actual floodplain, whichever is more restrictive. 7. Proposed Subdivision Lots Removed from or adjacent to Floodplains. This subsection 7 applies to subdivisions where any proposed lots are required to be removed from the floodplain or where any proposed lots are adjacent to the floodplain. In either such case, an approved CLOMR or Floodplain Modification Study will be required prior to the City's approval of a final plat. A plat restriction shall prohibit the issuance of building permits on the affected lots until a LOMR or LOMA has been issued by FEMA and the appeal period has expired or a similar map change process has been approved by the City for non-FEMA mapped floodplains. 8. Freeboard. Basements in structures on lots directly adjacent to a floodplain will be required to have two (2) feet of freeboard above the BFE. J. Recreational Vehicles. Recreational vehicles as defined in Article 16 of the LDC shall be allowed to park in floodplains for purposes of loading or unloading, preparing for service or preparing for storage not exceeding forty-eight (48) hours.
Ask a question about Centennial law
Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.
