For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-2-30 — Amendments

Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 18-2-30

Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/d8fab7bf-f900-496c-804f-ca6e4ca61eeb

Sec. 18-2-30. - Amendments.

Additions, deletions, amendments and changes to the IRC, as adopted by reference pursuant to Section 18-2-10, are hereby adopted as follows: (1) IRC Section R101.1. IRC Section R101.1 (Title) is amended by the addition of the term "City of Centennial" where indicated. (2) IRC Section R102.7. IRC Section R102.7 (Existing Structures) is amended by replacing the words "International Property Maintenance Code" with the words "Centennial Property Maintenance Code." (3) IRC Section R105.2. IRC Section R105.2 (Work exempt from permit) is amended by deleting item 10 from this section. (4) IRC Section R105.3.1. IRC Section Rl05.3.l (Action on Application) is hereby amended by the addition of a new Section R105.3.l.2, entitled "Election to Proceed Under Previous Code" to read as follows: R105.3.1.2 Election to Proceed Under Previous Code. Within the first 180 days following the adoption of this code, an applicant under subsection 105.3 may elect to, and if approved by the Building Official, proceed under the set of codes previously adopted and in effect on July 1, 2015; provided, however, that said election must be made certain and in writing, and under no circumstances shall an applicant be permitted to proceed partially under one set of codes and partially under the other. (5) IRC Section R108.5. IRC Section R108.5 (Refunds) is amended by deleting the section in its entirety and replacing the section with the following: The City may authorize refunding of any fee paid hereunder which was erroneously paid or collected. The City may authorize refunding of not more than 80 percent (80%) of the permit fee paid when no work has been done under a permit issued in accordance with this Code. The City may authorize refunding of not more than 80 percent (80%) of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or cancelled before any plan reviewing is done. The City shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than 180 days after the date of fee payment. (6) IRC Section R109.1.1. IRC Section R109.1.1 (Foundation inspection) is amended by deleting the section in its entirety and replacing the section with the following: Inspection of the foundation shall be made after poles or piers are set or trenches or basement areas are excavated and any required forms erected and any required reinforcing steel is in place and supported prior to the placing of concrete. The foundation inspection shall include excavations for thickened slabs intended for the support of bearing walls, partitions, structural supports, or equipment and special requirements for wood foundations. Inspections shall be performed by a Colorado licensed professional engineer or architect that is registered in the State of Colorado. A stamped written report shall be provided to the Building Official of the results for these inspections by a Colorado licensed professional engineer or architect that is registered in the State of Colorado. (7) IRC Section R112. IRC Section R112 (Board of Appeals) is amended by deleting the section in its entirety. (8) IRC Section R202. IRC Section R202 (Definitions) is amended by addition of the following: "Sleeping Room" (Bedroom) Any enclosed habitable space within a dwelling unit, which complies with the minimum room dimension requirements of IRC Sections R304 and R305 and contains a closet, an area that is useable as a closet, or an area that is readily convertible for use as a closet. Living rooms, family rooms and other similar habitable areas that are so situated and designed so as to clearly indicate these intended uses, shall not be interpreted as sleeping rooms. (9) IRC Table R301.2 (1). IRC Table R301.2 (1) is filled to provide the following: Table R301.2 (1) Climatic and Geographic Design Criteria Ground Snow Load (o) | Wind Design | Seismic Design Cate- gory (f) | Subject to Damage From | Winter Design Temp | Ice Barrier Under- layment Req- uired (h) | Flood Hazard | Air Freez- ing Index | Mean Annual Temp Speed (mph) | Topo- graphic Effects (k) | Special wind region (l) | Wind- borne debris zone (m) | Weath- ering (a) | Frost Line Depth (b) | Termite (c) 30 psf | 115 mph | NO | NO | NO | 8 | Severe | 36 in. | Slight to Mode- rate | 1 | YES | 08/01/97 | 1000 | 45°F Elevation | Altitude correction factor* | Coincident wet bulb | Indoor winter design relative humidity | Indoor winter design dry bulb temperature | Outdoor winter design dry bulb temperature | Heating temperature difference 5830 | 0.84 | 59 | 30% | 70* | 1 | 69 Latitude | Daily range | Summer design gains | Indoor summer design relative humidity | Indoor summer design dry bulb temperature | Outdoor summer design dry bulb temperature | Cooling temperature difference 39 | H | — | 50% | 75* | 91 | 16 (10) IRC Section R313.2. IRC Section R313.2 (One- and two-family dwellings automatic fire sprinkler systems.) Amended by deletion of section in its entirety and replacing the section with the following: An automatic residential fire sprinkler system shall be a required builder provided option in all new one- and two-family dwellings. (11) IRC Section R401.2. IRC Section R401.2 (Requirements) is amended by the addition of the following: Where soils reports show the need for it, foundations shall be designed and the construction drawings stamped by a Colorado registered design professional. The foundation design must be based on an engineer's soils report. The drawings must be noted with the engineering firm name, specific location for design and soils report number. A site certification prepared by State of Colorado registered design professional is required for setback verification on all new Group R Division 3 occupancies. (12) IRC Section G2413.2. IRC Section 02413.2 (Maximum gas demand) is amended to include the following table. CHAPTER 24 FUEL GAS TABLE G2413.2 (402.2) APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES APPLIANCE | INPUT BTU/H (Approx.) Space Heating Units Hydronic boiler Single family | 100,000 Multifamily, per unit | 60,000 Warm-air furnace Single family | 100,000 Multifamily, per unit | 60,000 Space and Water Heating Units Hydronic boiler Single family | 170,000 Multifamily, per unit | 75,000 Water Heating Appliances Waler heater, automatic instantaneous Capacity at 2 gal./minute | 142,800 Capacity at 4 gal./minute | 285,000 Capacity at 6 gal./minute | 428,400 Water heater, automatic storage, 30 to 40 gal. tank | 35,000 Water heater, automatic storage, 50-gal. tank | 50,000 Water heater, domestic, circulating or side-arm | 35,000 Cooking Appliances Built-in oven or broiler unit, domestic | 25,000 Built-in top unit, domestic | 40,000 Range, free-standing, domestic | 55,000 Other Appliances Barbecue | 40,000 Clothes dryer, Type 1 (domestic) | 35,000 Gas fireplace, direct-vent | 40,000 Gas light | 2,500 Gas log | 80,000 Refrigerator | 3,000 (13) IRC Section G2417.4.1. IRC Section G2417.4.1 (Test pressure) is amended by changing "3 psig" to "10 psig." (14) IRC Section P2603.5.1. IRC Section P2603.5.1 (Sewer depth) is amended by filling in both areas where indicated to read "12 inches (305 mm)."

(Ord. 2015-O-15 §2; Ord. 2018-O-21, §4; Ord. No. 2023-O-06, §4)

Ask a question about Centennial law

Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.