§ 18-6-30 — Amendments
Municipal Code, City of Centennial, Colorado (Supp. 26 Update 4: codified through Ordinance of August 18, 2026 (online updated October 28, 2026)) · Centennial Municipal Code § 18-6-30
Corpus is an independent public-information project, not the official City of Centennial website. Stable reference: corpuslaw.us/code/a538ab3f-e79c-4a5c-8ba7-7dc4f5c680bb
Sec. 18-6-30. - Amendments.
The following deletions, additions, insertions, and changes are hereby made to the IECC as adopted by reference by Section 18-6-10. In the event of a conflict between these amendments and the IECC, the provisions of this Section 18-6-30 shall control: (1) IECC Section 101.1 (Title) is amended by the addition of the term "City of Centennial" where indicated. (2) IECC Section C402.5 is amended to read as follows: a. C402.5. Buildings shall be tested for air leakage in accordance with approved testing standards. b. C402.5.1 Testing Procedures. Testing shall include whole-building pressurization testing conducted by an approved agency. Air leakage rates shall comply with the requirements of the 2021 IECC. (3) IECC Section C402.5.3 is deleted in its entirety. (4) IECC Section C403 is amended to read as follows: Mechanical systems shall comply with Section C403. Section C403.2.5 (Fault Detection Diagnostics) and C403.3 (Economizers) are required per IECC thresholds. (5) IECC Section C403.9. A new Section C403.9 is added to read as follows: a. Buildings shall be provided with demand response-ready controls capable of receiving and automatically responding to external signals, including HVAC setpoints and lighting adjustments. b. Exception: Systems not capable of receiving external signals shall not be required to actively participate but shall require demand response ready controls. (6) IECC Section C405.2 is amended to read as follows: a. C405.2. Lighting systems shall comply with Sections C405.2.1, C405.2.1.1, and C405.2.3 with required functional testing. b. C405.2.1 Functional Testing. Lighting control systems shall be tested to verify proper operation. (7) IECC Section C405.5 is deleted in its entirety. (8) IECC Section C405.11. A new Section C405.11 is added to read as follows: a. A minimum of twenty percent (20%) of parking spaces shall be EV-capable with raceway installed. b. A minimum of ten percent (10%) of parking spaces shall be EV-ready with panel capacity and wiring installed. c. Panel capacity shall be reserved for future electric vehicle charging loads. Where the cost of compliance exceeds 1% of total electrical system cost, the Building Official may approve a reduced installation upon receipt of a documented cost analysis demonstrating that compliance exceeds this threshold. (9) IECC Section C405.12. A new Section C405.12 is added to read as follows: a. Buildings shall include a solar-ready zone defined as structurally supported unobstructed roof area with conduit and panel capacity. b. Conduit pathways shall be installed from the electrical service to the roof. c. Electrical panel capacity shall be reserved for future photovoltaic systems. (10) IECC Section C406 is deleted in its entirety. (11) IECC Section C408 is amended to read as follows: a. C408.1 General. Mechanical systems shall comply with IECC C408, including testing, verification, and reporting. b. C408.2 Mechanical Systems Commissioning. The following systems shall be commissioned: HVAC systems and controls; economizers; and demand control ventilation systems. c. C408.3 Functional Performance Testing. Systems shall be tested to verify operation in accordance with design intent, including part-load and full-load conditions. d. C408.4 Documentation. A commissioning report shall be provided to the building official prior to final inspection and shall include test procedures, results, and deficiencies with corrective actions. (12) IECC Section R402.4.4 is deleted in its entirety. (13) IECC Section R503.1.2 is amended by the deletion of reference to Section R403.
(Ord. 2015-O-15 §2; Ord. 2023-O-06, §12; Ord. 2026-O-08, §2)
Ask a question about Centennial law
Corpus searches the Centennial sections it holds and shows the ones that match, with their citations. Free, no sign-in.
