For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21-4400 — FP Floodplain Overlay District

Revised Municipal Code of the City of Commerce City, Colorado (Codified through Ordinance No. 2732, adopted November 17, 2025. (Supp. No. 29)) · Commerce City Land Development Code § 21-4400

Corpus is an independent public-information project, not the official City of Commerce City website. Stable reference: corpuslaw.us/code/a89ed869-a91f-4985-8d94-5fbd5635b96f

Sec. 21-4400. - FP Floodplain Overlay District.

(1) Description, Purpose and Intent. This district includes all special flood hazard areas and areas removed from the floodplain by the issuance of a FEMA Letter of Map Revision Based on Fill (LOMR-F) within the jurisdiction of the city. The special flood hazard areas identified by the Federal Emergency Management Agency in the most current edition of the scientific and engineering report entitled, "The Flood Insurance Study for Adams County," with accompanying Flood Insurance Rate Maps and/or Flood Boundary-Floodway Maps (FIRM and/or FBFM) and any revisions thereto, are hereby adopted by reference and declared to be a part of this Code. These special flood hazard areas identified by the FIS and attendant mapping are the minimum area of applicability of this article and may be supplemented by studies designated and approved by the city. A copy of the Flood Insurance Study (FIS), DFIRMs, FIRMs and/or FBFMs is on file with the city and available for public inspection. The purpose of this district is to promote public health and minimize losses due to flood. (2) Use-by-Right. Agricultural uses, not requiring structures, such as general farming and the raising of plants, flowers, livestock, and nursery stock shall be a use-by-right in the floodway fringe to the extent such use is permitted by the underlying zoning district classification. (3) Uses Allowed with a Floodplain Permit. The following uses shall be permitted to occur within the floodway fringe area of the district only and to the extent that they are permitted by the underlying zoning district classification. These uses require a floodplain permit as outlined in section 21-3213 of this land development code. In cases where the floodway and floodway fringe are not delineated on the zoning map, the floodplain administrator may require the applicant to demonstrate, through documentation provided by a registered professional engineer, that the proposed use is within the floodway fringe. (a) Public or private recreational uses, such as parks and recreation fields; golf courses; hiking, biking, and horse trails; and accessory parking lots; (b) Public or private utility facilities, not requiring buildings, such as transmission lines, pipelines, utility lines, roadways, railroad spurs, and bridges; (c) Wildlife and nature preserve, game farm and fish hatchery uses not requiring buildings; (d) Regional public facilities, including detention or retention or water quality enhancement facilities; or (e) Barbed wire and split rail fences. Other types of fences such as chain link or solid screen types are allowed as a use by right only if necessary for safety or security reasons provided the fence is specially designed to minimize impeding the flow of flood waters, accumulation of debris or being subject to being easily moved during flood periods. Fence designs which meet the above criteria, such as certain breakaway fencing, or fencing with slatted design allowing water to pass through will be allowed if properly certified by a registered professional engineer as meeting the identified performance standards. Fences shall require a floodplain permit. (4) Exclusions. The following uses are prohibited in the floodplain overlay district: (a) Residential buildings and structures; and (b) Commercial buildings and structures. (5) Uses Not Identified. Uses not identified in this section shall be submitted to the floodplain administrator for review. If approved, the floodplain administrator may require any conditions and restrictions deemed necessary to protect the public health, safety, and welfare provided they are consistent with these standards and regulations. (6) General Standards. (a) When allowed, all new construction or substantial improvements shall be anchored to prevent flotation, collapse, or lateral movement of the structure and capable of resisting hydrodynamic and hydrostatic loads. (b) All new construction or substantial improvements shall be constructed: (i) With materials and utility equipment resistant to flood damage; (ii) Using methods and practices that minimize flood damage; and (iii) With electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (c) Utilities. (i) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; (ii) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from the systems into flood waters; and (iii) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. (7) Structures. (a) Generally. Residential structures are prohibited in the floodplain. Nonresidential structures, if permitted, shall either have the lowest floor (including the basement) elevated to one foot above the base flood elevation or, together with the attendant utility and sanitary facilities, comply with the following standards: (i) Be flood-proofed so that below the required elevation the structure is watertight with walls substantially impermeable to the passage of water; (ii) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and (iii) Be certified by a licensed engineer or architect that the design and method of construction are in accordance with the accepted standards of practice for meeting the provisions of this code. Such certification shall be provided to the floodplain administrator. (b) Critical Facilities. (i) No new, substantially improved, or additions to critical facilities shall be permitted in the floodplain unless the lowest floor or floodproofing of the structure, together with attendant utility and sanitary facilities, are at least two feet above the Base Flood Elevation. (ii) New critical facilities shall, when practicable as determined by the city, have continuous noninundated access (ingress and egress for evacuation and emergency services) during a 100-year flood event. (8) Floodways. (a) Floodways are extremely hazardous areas due to the velocity of flood waters that carry debris, potential projectiles and erosion potential. Accordingly, all encroachments are prohibited. Specifically, but without limitation, this means that no fill, construction, substantial improvements or other development shall be permitted within the floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment will not result in any increase in flood levels within the boundaries of the city during the occurrence of the base flood discharge. If so demonstrated, any new construction or substantial improvements shall comply with the standards contained in this section. (b) The following uses shall be permitted upon approval of a floodplain permit: (i) Public recreation uses such as parks, golf courses; and hiking, biking, and horse trails; (ii) Public/utility facilities such as transmission lines, pipelines, roadways, and bridges. (9) Properties Removed From the Floodplain by Fill. If permitted, new structures and additions to existing structures shall comply with the following: (a) In residential structures the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), must be elevated to one foot above the base flood elevation that existed prior to the placement of fill. (b) In nonresidential structures the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), must be elevated to one foot above the base flood elevation that existed prior to the placement of fill, or together with attendant utility and sanitary facilities be designed so that the structure or addition is watertight to at least one foot above the base flood level that existed prior to the placement of fill with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy.

(Ord. No. 1785, June 2010; Ord. No. 1992, March 2014; Ord. No. 2122, March 2017)

Ask a question about Commerce City law

Corpus searches the Commerce City sections it holds and shows the ones that match, with their citations. Free, no sign-in.