§ 15-160 — License classifications; fees; renewals
Fort Collins Municipal Code (Supp. No. 156, Update 2: codified through Ordinance No. 122, 2026, enacted September 15, 2026) · Fort Collins Municipal Code § 15-160
Corpus is an independent public-information project, not the official City of Fort Collins website. Stable reference: corpuslaw.us/code/16be85dd-64a1-4250-a4b2-6510fdf592be
Sec. 15-160. - License classifications; fees; renewals.
(a) The particular contractor license required and corresponding maximum scope of construction authorized under each license is described hereunder. All licenses are valid for a period of two (2) years from the date of issuance, and the fee for each license is two hundred dollars ($200.). A license may be renewed provided that said biennial fee is paid within sixty (60) days following the anniversary date such license was issued. When the license fee is not paid within such sixty-day period, the license shall expire and is not eligible for renewal. The holder of an expired license may be reissued such license by submitting a new application and paying all applicable fees as set forth in § 15-158. (b) Plumbers and exempt specialized trade subcontractors shall pay registration fees in accordance with § 15- 154. (c) The Class A, A-DR, B, B-DR, C-1, C-1-DR, C-2, C-2-DR, D-1, D-2, D-DR, E, ER and MM general contractor licenses described in this Section and their employees may perform specialized trade contractor work such as roofing, demolition or deconstruction, framing and awnings on projects for which permits have been issued to the general contractor. The listed licenses do not authorize the holders thereof or their employees to perform specialized trade contractor work described to the following specialized construction trades: electric, plumbing, HVAC, refrigeration, solar energy, alarms, fire-sprinkler systems, special fire extinguishing, gas piping, WTS and flammable fuel facilities. (1) A Class A general contractor license holder shall be authorized to construct, demolish or deconstruct any building or structure in the City that is regulated under the building code, including all work authorized by license types below this level. (2) A Class A-DR Structural Damage Repair/Restoration license holder shall be authorized to make repairs or restoration to structural damage to any building or structure in the City regulated under the building code, including all work authorized by damage repair and restoration license types below this level. (3) A Class B general contractor license holder shall be authorized to construct, demolish or deconstruct any building or structure in the City regulated under the building code up to and including five (5) stories in height, and including all work authorized by license types below this level. (4) Class B-DR Structural Damage Repair/Restoration license holder shall be authorized to make repairs or restoration to structural damage to any building in the City regulated under the building code, up to and including five (5) stories in height, and including all work authorized by damage repair and restoration license types below this level. (5) A Class C-1 general contractor license holder shall be authorized to construct, demolish or deconstruct any building or structure in the City that is regulated under the building code and which does not exceed three (3) stories in height of construction Types III, IV and V, and including all work authorized by license types below this level. (6) A Class C-1-DR Structural Damage Repair/Restoration license holder shall be authorized to make repairs or restoration to structural damage to any building or structure in the City regulated under the building code that does not exceed three (3) stories in height and limited to construction Types III, IV and V, including all work authorized by damage repair and restoration license types below this level. (7) A Class C-2 general contractor license holder shall be authorized to construct, demolish or deconstruct any building or structure in the City classified by the building code as Type V construction and a Group R or a Group U, Division 1 occupancy that does not exceed three (3) stories in height, including all work authorized by license types below this level, and including other ancillary Type V buildings or structures that are associated with a particular multi-family housing project, such as management offices, community and recreation buildings, maintenance buildings and similar uses. (8) A Class C-2-DR Structural Damage Repair/Restoration license holder shall be authorized to make repairs or restoration to: (1) structural damage to any building or structure in the City regulated under the building code classified as Type V construction and a Group R or a Group U, Division 1 occupancy which does not exceed three (3) stories in height; and (2) structural damage to other ancillary Type V buildings or structures that are associated with a particular multiple-unit housing project, including all work authorized by damage repair and restoration license types below this level. (9) A Class D-1 general contractor license holder shall be authorized to construct, demolish or deconstruct any building or structure in the City classified by the building code as a Group R, Division 3 occupancy housing not more than two (2) dwelling units, or a Group U, Division 1 occupancy or townhomes (aka single-family attached) as regulated by the International Residential Code, including all work authorized by residential license types below this level. (10) A Class D-2 general contractor license holder shall be authorized to construct, demolish or deconstruct residential garages of Group U, Division 1 occupancies up to one thousand (1,000) square feet; construct, demolish or deconstruct additions to detached single-family dwellings not exceeding one thousand (1,000) square feet in total floor area; perform any structural alterations or repairs to any building or structure in the City classified by the building code as a Group R, Division 3 occupancy housing not more than two (2) dwelling units, or a Group U, Division 1 occupancy; and construct or repair exterior decks of any size associated with single-family and/or multi-family project, including all work authorized by residential license types below this level. (11) A Class D-DR Structural Damage Repair/Restoration license holder shall be authorized to make repairs or restoration to structural damage to any building or structure in the City regulated under the building code as a Group R, Division 3 occupancy housing not more than two (2) dwelling units, or a Group U, Division 1 occupancy or townhomes (aka single-family attached) as regulated by the International Residential Code. (12) A Class E (commercial) general contractor license holder shall be authorized to perform any nonstructural alteration work to any building or structure in the City, including all work authorized by license types below this level. (13) A Class ER (residential) general contractor license holder shall be authorized to perform any non-structural alteration work to any residential building or structure in the City regulated under the International Residential Code, including single-family, duplex and townhomes (aka attached single-family), including all work authorized by Class MM (Miscellaneous and Minor Structures). (14) A Class MM (Miscellaneous and Minor Structures) general contractor license holder shall be authorized to construct, demolish or deconstruct the following projects associated with detached single-family dwellings: detached structures such as shelters, storage sheds, playhouses, greenhouses and gazebos, unenclosed structures such as open carports, patio covers, open porches and decks. All such projects shall be limited to one-story buildings or structures not exceeding three hundred (300) square feet in floor area. (d) A specialized trade contractor license and a specialized trade contractor supervisor certificate shall be required for any contractor performing any specialized trade listed herein. Prior to any specialized trade supervisor being issued a supervisor certificate, the applicant for such certificate shall successfully complete a written examination as provided in § 15-157, or the applicant shall provide proof of equivalent technical qualification as determined by the Building Official. Applicants for a specialized trade contractor license or a specialized trade contractor supervisor certificate shall submit an application and documents verifying that the applicant has acted in the principal role of contractor or primary project supervisor on no less than three (3) separate completed specialized trade projects as set forth under § 15-158 of this Article. Each specialized trade contractor license regulated under this Article is listed and described hereunder with respect to the scope of work authorized by each such license as follows: Alarm systems authorizes the installation, testing, maintenance and servicing of fire alarms as specified in the applicable provisions of the National Fire Alarm Code, NFPA 72 and the National Electrical Code, NFPA 70; including related wiring supplying not more than fifty (50) volts that does not require a state electrical license. Awnings authorizes the erection and attachment of awnings to buildings as regulated under the building code, including such awnings incorporating signage or graphics requiring a sign permit from the City. Demolition authorizes the razing of entire buildings and other structures regulated by the building code, excluding such work as deconstruction, partial or interior demolition work associated with alterations. Electricians authorizes the installation of electrical systems as regulated by the State of Colorado. Fire sprinkler system authorizes the installation of automatic fire suppression systems, including standpipes that use pressurized water as the primary extinguishing agent, and which are designed to protect entire buildings, rooms or areas and processes, other than combination potable water/residential fire sprinkler systems regulated under the International Residential Code. Fireplace appliances authorizes the installation of nonportable listed manufactured fuel-burning fireplace appliances and associated chimneys or vents, excluding equipment for industrial processes or for providing primary space heating, ventilation, cooling or water heating; and excluding any building modifications, alterations or additions. Flammable fuel facilities authorizes the installation, alteration or removal of tanks, piping and dispensing equipment for petroleum fuels or other fuels as regulated by the City fire code, including related electrical wiring supplying not more than fifty (50) volts. Gas piping authorizes the installation of piping and fittings for supplying fuel-gas, and the replacement of water heaters when such water heater replacement does not involve alteration of water supply piping or appliance venting. HVAC-C (commercial) authorizes the installation of environmental nonportable heating, ventilation, air conditioning systems including commercial boilers and the related piping, ducts, venting, appliances, controls and electrical wiring (supplying not more than fifty [50] volts), including all work authorized by HVAC-R and HVAC-RR. HVAC-R (residential) authorizes the installation of environmental nonportable heating, ventilation, air conditioning systems, including residential boilers and replacement of equipment, for single-family dwelling units including duplex, multi-family and townhomes (aka single-family attached) and the related piping, ducts, venting, appliances, controls and electrical wiring (supplying not more than fifty [50] volts). HVAC-RR (repair and replacement) authorizes the replacement installation of environment nonportable heating, ventilation, air conditioning equipment and the related piping, ducts, venting, appliances, controls and electrical wiring (supplying not more than fifty [50] volts) associated with the repair or replacement. Plumbers authorizes the installation of plumbing systems as regulated by the State of Colorado. Refrigeration authorizes the installation of nonportable evaporative, absorption and mechanically operated refrigeration equipment, including piping, vessels, controls and electrical wiring (supplying not more than fifty [50] volts). Roofing authorizes the application of nonstructural roof covering and materials as regulated by the building code, including the replacement or repair of sheathing on existing roofs of slopes two (2) inches in twelve (12) inches or steeper. Roofing plus authorizes the application of nonstructural roof covering and materials as regulated by the building code, including the replacement or repair of sheathing on existing roofs or slopes less than two (2) inches in twelve (12) inches. Signs authorizes the installation and erection of permanent signs requiring a sign permit from the City, excluding electrical work regulated by the City electrical code requiring a state license. Solar energy hydronic authorizes the installation of solar heat collectors, storage tanks and related piping, and related electrical wiring supplying not more than fifty (50) volts. Solar energy PV authorizes the installation of photovoltaic collectors and related electrical wiring supplying stand-alone or utility grid systems. Wood frame construction (framing) authorizes the construction of Type IV and Type V structural framing systems as regulated under the building code, including the application of sheathing and siding. WTS authorizes the installation of outdoor wireless telecommunication systems, including related equipment, towers, antennas and the construction of unoccupied minor related buildings housing only equipment, and associated cables and electrical wiring supplying not more than fifty (50) volts that does not require a state electrical license.
(Ord. No. 75, 1987, § 1, 5-5-87; Ord. No. 108, 1992, § 8, 11-3-92; Ord. No. 120, 1995, 10-3-95; Ord. No. 36, 2001, 3-6-01; Ord. No. 122, 2012, § 9, 11-20-12)
Ask a question about Fort Collins law
Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.
