Sec. 5-112. - Amendments and deletions to the 2024 International Fuel Gas Code.
The 2024 International Fuel Gas Code adopted in § 5-111 is amended as follows: 1. Section 101.1 Title is amended to read as follows: 101.1 Title. These regulations shall be known as the Fuel Gas Code of the City of Fort Collins, hereinafter referred to as "this code." 2. Section 102.8 Referenced codes and standards is amended to read as follows: Section 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Section 101.4 of the adopted International Building Code, entitled "Referenced codes," and such codes and standards shall be considered to be part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.8.1 and 102.8.2. Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and the manufacturer's installation instructions shall apply. 3. SECTION 103 (IFGC) CODE COMPLIANCE AGENCY is deleted in its entirety and replaced with the following: SECTION 103 CODE ADMINISTRATION 103.1 Entity charged with code administration. The entity charged with code administration shall be as determined in accordance with Section 103 of the adopted International Building Code, entitled "CODE ADMINISTRATION." 4. Section 104.2.4.1 Flood hazard areas is deleted in its entirety and replaced with the following: 104.2.4.1 Flood hazard areas. For existing buildings or structures regulated under the scope of this code that are in whole or in part located in flood hazard areas, construction documents shall be submitted as established in accordance with Chapter 10 of the City Code, entitled "Flood Prevention and Protection." 5. Section 105.1.1 Annual permit and Section 105.1.2 Annual permit records are deleted in their entirety. 6. SECTION 108 (IFGC) FEES is deleted in its entirety and replaced with the following: SECTION 108 FEES 108.1 Fees. All items relating to fees shall be as specified in Section 109 of the adopted International Building Code, entitled "FEES." 108.2 Work commencing before permit issuance. All items related to work commencing before permit issuance shall be made pursuant to the applicable provisions of Section 109.2 of the adopted International Building Code. 7. SECTION 112 (IFGC) MEANS OF APPEAL is deleted in its entirety and replaced with the following: SECTION 112 MEANS OF APPEAL. 112.1 General. Appeals of decisions, determinations and interpretations of this code shall be done in accordance with the applicable provisions and procedures of Section 113 of the adopted International Building Code, entitled "MEANS OF APPEALS." 8. Section 113.4 Violation penalties is deleted in its entirety and replaced with the following: 113.4 Violation penalties. Any person who violates a provision of this code or fails to comply with any of the requirements thereof or who alters or repairs a building or structure in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, commits a civil infraction and is subject to the provisions contained in § 1-15(f) of the City Code. Each day that a violation continues shall be deemed a separate offense. 9. Section 301.3 Listed and labeled is amended to read as follows: 301.3 Listed and labeled. Appliances regulated by this code shall be listed and labeled for the application in which they are used unless otherwise approved in accordance with Section 105. 10. Section 303.3 Prohibited locations is amended to read as follows: 303.3 Prohibited locations. Appliances shall not be located in sleeping rooms, bathrooms, toilet rooms, storage closets or surgical rooms, or in a space that opens only into such rooms or spaces, except where the installation complies with one of the following: 1. The appliance is a direct-vent appliance installed in accordance with the conditions of the listing and the manufacturer's instructions. 2. Vented room heaters, wall furnaces, vented decorative appliances, vented gas fireplaces, vented gas fireplace heaters and decorative appliances for installation in vented solid fuel-burning fireplaces are installed in rooms that meet the required volume criteria of Section 304.5. 3. The appliance is installed in a room or space that opens only into a bedroom or bathroom, and such room or space is used for no other purpose and is provided with a solid weather-stripped door equipped with an approved self-closing device. Combustion air shall be taken directly from the outdoors in accordance with Section 304.6. 4. A clothes dryer is installed in a residential bathroom or toilet room having a permanent opening with an area of not less than 100 square inches (0.06 m 2 ) that communicates with a space outside of a sleeping room, bathroom, toilet room or storage closet. 11. Section 304.11 Combustion air ducts is amended to read as follows: 304.11 Combustion air ducts. Combustion air ducts shall comply with all of the following: 1. Ducts shall be constructed of galvanized steel complying with Chapter 6 of the International Mechanical Code or of a material having equivalent corrosion resistance, strength and rigidity. Exception: Where the installation of galvanized steel ducts is not practical due to existing finish materials within dwellings units that are undergoing alteration or reconstruction, unobstructed stud and joist spaces shall not be prohibited from conveying combustion air, provided that not more than one required fireblock is removed. … 9. All combustion air openings or ducts shall be readily identifiable with an approved label or by other means warning persons that obstruction of such openings or ducts may cause fuel-burning equipment to release combustion products and dangerous levels of carbon monoxide into the building. 12. Section 305.1 General is amended to read as follows: 305.1 General. Equipment and appliances shall be installed as required by the terms of their approval, in accordance with the conditions of listing, the manufacturer's instructions and this code. Manufacturers' installation instructions shall be available on the job site at the time of inspection. Where a code provision is less restrictive than the conditions of the listing of the equipment or appliance or the manufacturer's installation instructions, the conditions of the listing and the manufacturer's installation instructions shall apply. 13. Section 404.12 Minimum burial depth is amended to read as follows: 404.12 Minimum burial depth. Underground piping systems shall be installed a minimum depth of 18 inches 457 mm) below grade. 14. Section 404.12.1 Individual outdoor appliances is deleted in its entirety. 15. Section 406.4.1 Test pressure is deleted in its entirety and replaced with the following: 406.4.1 Test pressure. The test pressure to be used for non-welded pipe shall not be less than 10 psi. 16. Section 501.8 Appliances not required to be vented is amended to read as follows: 501.8 Appliances not required to be vented. The following appliances shall not be required to be vented: 1. Electrical ranges. 2. Built-in domestic cooking units listed and marked for optional venting. 3. Hot plates and laundry stoves. 4. Type 1 clothes dryers (Type 1 clothes dryers shall be exhausted in accordance with the requirements of Section 614). 5. A single booster-type automatic instantaneous water heater, where designed and used solely for the sanitizing rinse requirements of a dishwashing machine, provided that the heater is installed in a commercial kitchen having a mechanical exhaust system. Where installed in this manner, the draft hood, if required, shall be in place and unaltered and the draft hood outlet shall be not less than 36 inches (914 mm) vertically and 6 inches (152 mm) horizontally from any surface other than the heater. 6. Refrigerators. 7. Counter appliances. 8. Direct-fired makeup air heaters. 9. Specialized appliances of limited input such as laboratory burners and gas lights. Where the appliances listed in Items 5 through 9 are installed so that the aggregate input rating exceeds 20 British thermal units (Btu) per hour per cubic foot (207 watts per m 3 ) of volume of the room or space in which such appliances are installed, one or more shall be provided with venting systems or other approved means for conveying the vent gases to the outdoor atmosphere so that the aggregate input rating of the remaining unvented appliances does not exceed 20 Btu per hour per cubic foot (207 watts per m 3 ). Where the room or space in which the appliance is installed is directly connected to another room or space by a doorway, archway or other opening of comparable size that cannot be closed, the volume of such adjacent room or space shall be permitted to be included in the calculations. 17. Section 503.6.6 Minimum height is amended to read as follows: 503.6.6 Minimum height. A Type B or L gas vent shall terminate not less than 5 feet (1524 mm) in vertical height above the highest connected appliance draft hood or flue collar. A Type B-W gas vent shall terminate not less than 12 feet (3658 mm) in vertical height above the bottom of the wall furnace. All gas vents shall terminate a minimum of 22 inches (559 mm) above the surface or grade directly below. 18. Section 621 (IFGC) UNVENTED ROOM HEATERS is deleted in its entirety. 19. A new Section 623.3.1 Kitchens with gas cooking is added to read as follows: 623.3.1 Kitchens with gas cooking. Gas cooking appliances in residential kitchens shall be supplied with an exhaust system vented to the outside. Ducts serving kitchen exhaust systems shall not terminate in an attic or crawl space or areas inside the building and shall not induce or create a negative pressure in excess of negative 3 Pa or adversely affect gravity-vented appliances. 20. Section 630.3 (IFGS) Combustion and ventilation air is amended to read as follows: 630.3 (IFGS) Combustion and ventilation air. Where infrared heaters are installed, natural or mechanical means shall provide outdoor ventilation air at a rate of not less than 4 cfm per 1,000 Btu/h (0.38 m 3 /min/kW) of the aggregate input rating of all such heaters installed in the space. Exhaust openings for removing flue products shall be above the level of the heaters.
(Ord. No. 022, 2014, § 2, 2-4-14; Ord. No. 076, 2017, § 3, 7-5-17; Ord. No. 156, 2018, § 3, 1-2-19; Ord. No. 028, 2022, § 4, 4-5-22; Ord. No. 218, 2025, § 3, 12-16-25)
Ask a question about Fort Collins law
Corpus searches the Fort Collins sections it holds and shows the ones that match, with their citations. Free, no sign-in.