§ 22-355 — Section 404.9 amended; above-ground outdoor piping
Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 22-355
Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/2708090d-759b-4c8b-9cc5-776bf6b485cf
Sec. 22-355. - Section 404.9 amended; above-ground outdoor piping.
Sec. 404.9 of the fuel gas code is amended to read as follows: 404.9 Above-ground outdoor piping. All piping installed outdoors shall be elevated not less than six inches (152 mm) above ground and where installed across roof surfaces, shall be elevated not less than six inches (152 mm) above the roof surface. Piping installed above ground, outdoors, and installed across the surface of roofs shall be securely supported and located where it will be protected from physical damage. Where passing through an outside wall, the piping shall also be protected against corrosion by coating or wrapping with an inert material. Where piping is encased in a protective pipe sleeve, the annular space between the piping and the sleeve shall be sealed.
(Code 1994, § 16.30.070; Ord. No. 47, 2016, §§ 1(exh. A), 2(exh. B), 12-20-2016)
Ask a question about Greeley law
Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.
