Sec. 22-421. - Application.
(a) New installations. This code applies to new installations. Buildings with construction permits issued after the date of adoption of this code by the state electrical board and/or the city shall comply with its requirements. (b) Existing installations. Existing electrical installations that do not comply with the provisions of this code shall be permitted to be continued in use unless the authority having jurisdiction determines that the lack of conformity with this code presents an imminent danger to occupants. Where changes are required for correction of hazards, a reasonable amount of time, as determined by the authority having jurisdiction, shall be given for compliance, depending on the degree of hazard. Life safety systems such as exit lighting systems, emergency egress lighting systems, ground fault circuit interrupter devices for personal protection, and smoke detectors may be required to be brought into compliance with current code requirements as determined by the authority having jurisdiction. (c) Additions, alterations, or repairs. Additions, alterations, or repairs to any building, structure, or premises shall conform to that required of a new building without requiring the existing building to comply with all the requirements of this code. Additions, alterations, installations, or repairs shall not cause an existing building to become unsafe or to adversely affect the performance of the building as determined by the authority having jurisdiction. Electrical wiring added to an existing service, feeder, or branch circuit shall not result in an installation that violates the provisions of the code in force at the time the additions are made. (d) Change of use. When any building, structure, or premises is occupied for a purpose that results in a change of use as determined by the chief building official, then the existing electrical service, distribution system, and branch circuit wiring for light, heat, power, and other purposes shall be inspected by the authority having jurisdiction to ensure that the existing electrical wiring is in compliance with the NEC © requirements for the new type of use. Any parts of the electrical systems found to be in violation shall be brought into compliance before the building can be occupied for the new use. (e) Relocated structures. The entire electrical service, distribution system, and branch circuit wiring for light, heat, power, and other purposes shall be installed to meet the requirements of a new installation whenever an existing structure is relocated within the city limits. All existing wiring systems, enclosures, panelboards, circuit breakers, fuses, luminaries and devices shall be removed in their entirety and not reused unless approved by the authority having jurisdiction prior to obtaining an electrical permit to rewire the structure. (f) Mobile and manufactured homes. Every mobile home, manufactured home, or movable structure shall have the electrical utility service or hookup inspected prior to obtaining new or different service to the unit. This inspection shall be requested when the mobile home, manufactured home or movable structure has passed all other inspections required for the applicable type of structure.
(Code 1994, § 16.32.210; Ord. No. 13, 2015, § 2, 6-2-2015)
Ask a question about Greeley law
Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.