Sec. 22-501. - Installation standards.

(a) Permit required for installation. No mobile home shall be installed on a home site without first obtaining a building permit from the building official for each such installation. (b) Mobile home inspection. Each mobile home shall be in generally sound physical condition as determined by the building official prior to the issuance of a permit. No mobile home shall be installed or placed upon a home site after the effective date of the ordinance form which this chapter is derived unless such home bears a label or has equivalent documentation certifying that the home was constructed in accordance with the Federal Manufactured Home Construction and Safety Standards Act of 1976 or NFPA, ANSI 119.1 or the equivalent. Mobile homes constructed before June 15, 1976, may be installed subject to approval on an individual basis by the building official, upon finding that the home is in safe, sound physical condition, and meets all other provisions of the standards specified in this chapter. Prior to the inspection by the building official, a permit shall be issued to the purchaser of the mobile home. This permit is to cover the costs of the inspection. (c) Site preparation and foundations. All pad site foundations shall be cleared of vegetation, located on undisturbed soil or approved fill and be graded such that supporting piers are plumb. The following foundation standards shall be applied, unless the building official approves equivalent techniques for site preparation and foundations that are as safe or safer than the techniques described herein. (d) Skirting. Each mobile home shall be provided with perimeter skirting between the ground and bottom of the mobile home floor within 30 days after utility connections are made. Such skirting shall be a durable rigid, weather-resistant siding material approved for such use, such as finished exterior plywood, fiberglass or equivalent material, all of similar style to that of the mobile home. Skirting shall be securely attached to the mobile home to prevent unsupervised access to mobile home utility connections. The building official may approve equivalent techniques for skirting for mobile homes if the official feels the equivalent techniques are as safe or safer than the techniques described herein. (e) Anchoring and tie-down requirements. General requirements. Every mobile home shall have an anchoring system installed which will prevent uplift, sliding, rotation and overturning. Such system shall be composed of approved cables, eye bolts, straps and other hardware sufficient to withstand a tensile load of 4,725 pounds at each anchor connection, without failure, creep or withdrawal. All such hardware shall be corrosion-resistant-coated steel or equivalent. (f) Tie-down requirements. Number of sets and anchors. Mobile homes up to 50 feet in length shall have two tie-down sets and four anchors. Mobile homes between 50 and 70 feet in length shall have three tie-down sets and six anchors. Mobile homes over 70 feet in length shall have four tie-down sets and eight anchors. (g) Tie-down requirements. Types of tie-downs allowed. Tie-downs shall be cable, steel strapping, steel bands or other materials having equivalent strength and holding power. The following tie-down requirements shall be applied unless the building official approves equivalent techniques for tie-downs or anchors that are as safe or safer than the techniques described herein: (1) Cable. When cable is used for tie-downs, it shall either be galvanized or stainless steel. The cable shall be at least three-eighths-inch diameter. Steel cable shall be 7 × 7 (seven strands of seven wires each). Aircraft cable may be used that is at least 7 × 19 (seven strands of 19 wires each). (2) Steel strapping. When flat steel strapping is used for tie-downs, it shall meet all federal specifications. Strapping shall have a breaking strength of 4,750 pounds and have zinc coating of a minimum of 0.30 ounce per square foot of surface. (3) Steel bands. Steel bands used for ties shall terminate with D-rings or other devices that will not cause distortion of the band with a tensioning device attached. (4) Use of other types of tie-downs. Other materials, connectors or means of securing tie-downs may be considered by the building official, provided they are equal to the above specifications in permanence, strength, holding power and weather resistance. (h) Tie-down requirements. Anchorage and turnbuckles. All ties shall be fastened to an anchorage and shall be drawn tight with one-half-inch or larger galvanized, drop-forged turnbuckles or other equivalent tightening device approved by the building official or the building official's designee. Turnbuckles are ended with jaws of forged or welded eyes. Turnbuckles with hook ends shall not be used. (i) Tie-down requirements; connections; prevention of cutting. Connection to the I-beam may be by a five-eighths-inch drop-forged closed eyed, bolted through a hole drilled through the beam. A washer or its equivalent is used so that the beam is sufficiently fishplated through the hole. Sharp edges of the mobile home that would tend to cut the cable when the home is buffeted by wind shall be protected by a thimble or other device to prevent cutting. (j) Anchorage. The anchoring system shall be composed of approved materials and installed in a manner to prevent movement. The following anchorage requirements shall be applied unless the building official approves equivalent techniques for anchors that are as safe or safer than the techniques described herein: (1) Over-the-home ties. When designed to accommodate over-the-home ties, ground anchors shall be aligned with piers and situated immediately below the outer wall of the mobile home, provided this placement allows for sufficient angle for anchor-to-frame connections. (2) Steel rods; dead anchors. Steel rods shall be of a five-eighths-inch minimum diameter with a forged or welded eye at the top; the bottom of the rod for dead-man anchors shall be hooked into the concrete. Dead-man anchors shall be sunk to a depth of at least three feet, with a minimum vertical dimension of two feet, and a diameter of six inches. (3) Concrete slabs. The building official may approve anchors to reinforced concrete slabs. Anchors shall be spaced a maximum of eight feet on center and no more than five feet from each end of the mobile home. No celled concrete block shall be provided. (4) Augers. Augers shall be at least six inches in diameter, with arrowheads of eight inches and shall be sunk to a depth of at least three feet. (k) Piers. One pier shall be required for each required anchorage. Required piers shall be centered under each main frame or chassis member within five feet of anchorage, and the end piers shall be no farther than five feet from the ends of the mobile home. (1) Piers and footings. All piers shall be placed on footers of concrete with a minimum dimension of 16 inches by 16 inches by four inches, or an equivalent approved by the building official. Piers shall be topped with a concrete cap eight inches by 16 inches by four inches. (2) Pier dimensions. Piers shall be constructed as standard eight inches by eight inches by 16 inches celled concrete blocks placed over the footings with the long dimension crosswise to the main frame members and centered under them with cells vertical. Piers shall be placed in a manner that allows the mobile home to be located as close to the ground as possible. (3) Piers; shims. Hardwood shims are driven tight between the cap and each side of the main frame to provide uniform bearing and are four inches or less in thickness and wide enough to provide bearing over the top cap. (4) Other types of piers and footings. The building official may approve other types of piers and footings of equivalent permanence and weight-bearing ability. (5) Metal stands. Metal stands engineered and designed for mobile home installation and approved by the building official may be used. Stands shall be installed per manufacturer's requirements. (l) Alternative tie-down and blocking methods. If a mobile home community owner or developer wishes to use different tie-down, blocking or anchorage systems than those required by this chapter, the owner shall first obtain approval from the city's building official, demonstrating compliance with this code and ordinances and with professional standards and methods. The planning commission shall grant approval at the time the proposed final site plan is under review. (m) Landings and porches. Each mobile home shall be provided with a minimum 36-inch by 36-inch, structurally independent, landing or porch within 7¾ inches, measured vertically to the top of the threshold, of all doorways. The required landing or porch shall be served by either stairs or ramp, guards and handrails and shall be constructed in accordance with the adopted residential code. (n) Structural additions. Additions, carports, decks and similar accessory structures or buildings shall not be structurally supported by or attached to a mobile or manufactured home unless the mobile or manufactured home is supported by and attached to an engineered permanent foundation, or engineering calculations are submitted to substantiate any proposed structural connection. Exception: The building official may waive the submission of engineering calculations if it is found that the nature of the work applied for is such that engineering calculations are not necessary to show conformance to these provisions.

(Code 1994, § 16.44.020; Ord. No. 70, 1998, § 1(part), 12-1-1998; Ord. No. 25, 2022, § 10(app. A, § 10), 8-2-2022, eff. 1-1-2023)

Ask a question about Greeley law

Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.