§ 24-602 — Nonresidential development standards
Municipal Code of the City of Greeley, Colorado (Codified through Ordinance No. 16, 2026, enacted April 21, 2026 (Supp. No. 6, Update 1)) · Greeley Municipal Code § 24-602
Corpus is an independent public-information project, not the official City of Greeley website. Stable reference: corpuslaw.us/code/0c62afcf-5909-46ca-a1e8-cbea3b5ae115
Sec. 24-602. - Nonresidential development standards.
a. District lot and building standards. The lot and building standards for nonresidential districts are specified in table 24-6-1. Table 24-6-1: Nonresidential District Lot and Building Standards Zoning District | Lot Standards | Minimum Setbacks | Building Height Size | Frontage Width | Open Space | Front [1] | Interior Side [2] | Corner Side [1] | Rear [2] C-L Commercial Low Intensity | n/a | 25'+ | 20% | 25' | 0' | 25' | 0' | 40' C-H Commercial High Intensity | n/a | 25'+ | 20% | 25' | 0' | 25' | 0' | 60' MU-L Mixed-Use Low Intensity | 20K s.f. max | 25'—100' | 15% | 0'—10' | 0' | 0'—10' | 0' | 40' MU-H Mixed-Use High Intensity | 2 ac. max | 25'—300' | 15% | 0'—10' | 0' | 0'—10' | 0' | 60' I-L Industrial Low Intensity | n/a | 50'+ | 10% | 25' | 0' | 25' | 0' | 40' I-M Industrial Medium Intensity | n/a | 100'+ | 10% | 25' | 0' | 25' | 0' | 40' I-H Industrial High Intensity | n/a | 100'+ | 10% | 25' | 0' | 25' | 0' | 60' [1] Front setbacks may be modified according to the frontage type design standards in section 24-603.b. [2] Non-street setbacks shall be as specified by the building code for each class of building. However, greater setbacks may be necessary to meet the building design standards or landscape standards applicable to a particular use or building. [3] Any district that permits residential uses may allow residential lots and buildings designed according to the residential building type standards in chapter 5 of this title. b. Dimension exceptions. The following are exceptions to setback and building dimensions standards established in table 24-6-1: 1. Setback encroachments. The following encroachments into the required setback are permitted, except in no case shall this authorize structures that violate the provisions of any easement: (a) Any projections over public rights-of-way, or any similar area designed for pedestrian circulation, shall be at least eight feet above the grade, and in no case within five feet of any curb for a street, through access drive or other area designed for vehicles. (b) Structural projections such as bay windows, balconies, awnings, canopies, chimneys, eaves, cornices, open fire escapes, egress wells, or other non-foundational overhangs or projections may extend up to four feet from the foundation and encroach into the setback, but no closer than three feet from any side or rear lot line. This exception shall be limited to no more than 20 percent of a building elevation. (c) Ground-mounted mechanical equipment, meters, and utility boxes accessory to the building may be located in the side or rear setback provided that it extends no more than six feet from the principal building, no closer than three feet to the lot line, and is screened from public right-of-way by structures or landscape. These limitations do not apply to any utility structures otherwise authorized to be located according to easements or in the right-of-way, which shall follow the location and design standards of those specific authorizations. (d) A lot may have more than one principal building, provided any accessory, secondary, or principal building shall be located at least ten feet from any other building on the same or adjacent lots, or be joined by a party wall meeting all aspects of the building code. (e) Any other accessory use or structure within the setback, not specified in section 24-602.c, shall have a setback of at least one-third its height from the property line. 2. Height exceptions. The following are exceptions to the height limits in table 24-6-2: (a) Building elements integral to the design and construction of the building, such as parapet walls, false mansards, or other design elements essential to a quality appearance of the building may extend up to six feet above the roof deck of a flat roof. (b) Architectural features such as chimneys, ornamental towers or spires, and similar accessory features that are less than 20 percent of the building footprint may extend up to 15 feet above the maximum building height, but in no case more than 50 percent above the actual building height. (c) Functional and mechanical equipment such as elevator bulkheads, cooling towers, smoke stacks, roof vents, or other equipment may be built up to their necessary height in accordance with building codes provided they are screened according to the standards of this code or otherwise incorporated into the architecture of the building. (d) Accessory site structures such as flagpoles, monuments, or water towers, may have a height limit of 50 feet, but shall be set back a distance of at least one-third its height from the property line. (e) One foot of additional height may be permitted for each one foot in additional setback, up to a maximum of ten additional feet above the maximum height limit. For any structure using this exception where there is no required setback, and default required setback of ten feet shall be used for applying this exception. The additional setback area shall be used for landscape areas required by section 24-803 or open space meeting the standards of section 24-603.d. (f) All height exceptions shall be in conformance with air space regulations relative to the airport overlay district in section 24-1002. c. Accessory buildings — Nonresidential. Accessory buildings shall be permitted in association with and on the same lot as a principal building, subject to the standards in table 24-6-2, and to the following additional limitations: Table 24-6-2: Nonresidential Accessory Structures Type | Quantity | Size | Height | Setbacks Minor structure (small shed, and similar structures) | • 1/lot; • + 1/each additional 10k s.f.; • Maximum of 3 | • 120 s.f. max. | • 12' max. | • 0' side or rear; • 5' if on a concrete slab or similar foundation; and • 25' on any street side lot line • Behind the rear building line of the principal structure Secondary building (detached accessory building) | • 1/principal building | • 25% max. of principal building footprint, up to 1,200 s.f. max. | • 25' max., but no higher than principal structure | • 5' from side and rear; • 10' from street side; and • At least 12' behind the front building line of the principal structure Any building over 12' high or more than 250 s.f. footprint shall meet the design standards in section 24-502.c.2 1. Generally. (a) All accessory buildings shall be at least ten feet from the principal building, or other distance specified by applicable building codes based on fire ratings of adjacent walls. (b) Accessory buildings shall be clearly incidental and subordinate to the principal building or use, in terms of scale, location, and orientation. (c) Minor accessory structures of 120 square feet or less, and not on a slab or similar foundation do not have a required interior side or rear setback, but should be movable and are otherwise placed "at risk" by the owner with regard to any easements, fence, or screening requirements. 2. Secondary building standards. In any nonresidential district, secondary buildings over 250 square feet footprint or 12 feet high shall meet the following massing and design standards to ensure compatibility with the principal structure: (a) Any portion of the building or structure potentially visible from the street or other public areas shall use materials, colors, scale and forms (roofs and massing), and architectural details that are compatible with the principal structure, or otherwise be screened according to section 24-803. (b) Any building or structure exceeding the limits in table 24-6-2 shall be treated as a second principal building and meet all lot and building design standards applicable to principal buildings. d. Fences and walls. Fences and walls in nonresidential districts shall be limited to the sizes and locations in table 24-6-3. Table 24-6-3: Nonresidential Fences and Wall Location Front In the front setback or any location in front of front building line. | • 3.5' high • 3.5'—6' if it is ornamental design that is at least 75% open (i.e., wrought iron). • Up to 8' for ornamental features at pedestrian entries. Side and rear In the side, street side, or rear yard and behind the front building line. | • 6' high; • 8' in the I-M or I-H district, provided the fence remains open (i.e., wrought iron or chain link) • A fence or wall outside of required setbacks (i.e., in the buildable envelope), and behind front building line can exceed 6', but may be limited by building codes or other general development and design standards. Perimeter fences Any fence within 30' of a collector or arterial street right-of-way as part of perimeter landscape in section 24-803. | Any fence designed as part of a perimeter landscape area along collector or arterial streets, or otherwise located within 30' of a collector or arterial right-of-way and longer than 100', shall meet the following standards: • All fencing shall be softened with landscape materials on the street side of fences meeting the perimeter landscape standards of section 24-802. • Expanses of over 100' shall be broken up by either: ◦ Offsets of +/- 3' on ⅓ of length for every 150' span; or ◦ Ornamental designs on at least 50' of every 150' space that is at least 75% open (i.e., wrought iron); or ◦ Architectural pillars or posts (i.e., stone, or masonry) at least every 50'. • Alternatives may be approved by the director in association with the perimeter landscape plans in section 24-803, and streetscapes in section 24-301. 1. General height and location standards. The following standards are applicable to fences and walls in all locations: (a) All fences or walls along rights-of-way or easements shall be located: (1) At least one foot from any ROW or easement that prohibits structures; otherwise fences in easements shall be permitted only subject to specific easement language and limitations. (2) At least two feet from any sidewalk. (3) At least three feet from the edge of any alley or similar vehicle access. (4) Fences or walls may only be located in the right-of-way or easement by a revocable right-of-way permit from the public works department. (b) All fences or walls located along common lot lines shall be located so: (1) The fence is on the property line; or (2) The fence is at least three feet from the property line. Any areas set back three feet or more, which could become enclosed by other similarly located fences, shall provide at least one gate for access and maintenance equipment. (3) The finished side faces adjacent property or any public right-of-way, public space or common areas. (c) Any fence or wall in the floodplain shall also require a floodplain development permit. (d) All fence or walls shall be located and designed to comply with sight distance requirements of section 24-301.d.2. Any fence or wall that could potentially create a sight obstruction for vehicles crossing pedestrian areas or entering the street may require greater transparency or additional location restrictions to allow for safe sight distances for the vehicle. (e) Temporary fences for construction may be up to six feet or as otherwise specified in construction permits. (f) All fences and walls may be subject to additional standards of the building code, approved drainage plans for the lot, or other design and development standards. In particular, any of the following allowed by these standards, permitted by alternative compliance, or approved by a variance, requires a building permit: (1) Any fence or wall over six feet high; (2) Any retaining walls over four feet high; (3) Walls in the setbacks over six feet high shall only be permitted by alternative compliance in section 24-208. 2. Materials. Fences and walls shall be consistent in architectural character, materials, and appearance of the principal building on the same lot. Fences shall be constructed out of any of the following materials: (a) Wood or vinyl simulating wood. Wood shall be either naturally rot resistant (such as cedar), or pressure treated for rot resistance; (b) Wrought iron or aluminum simulating wrought iron; (c) Stone, brick, concrete with stone or brick veneer, pre-cast concrete simulated stone or brick, or decorative concrete textured to simulate masonry; or (d) Chain link or vinyl clad chain link: (1) Chain link is permitted in the side or rear yard only in the C-L, C-H, MU-L and MU-H districts. (2) Chain link with slats is only allowed in the I-M and I-H districts, and proved it is not located along a collector or arterial street. (3) Chain link fences may be up to 12 feet for any security fence around sports facilities, courts, pools or similar facilities, provided it is 20 feet from any lot line and provided all portions over eight feet remain free of opaque screens. (e) Barbed wire may be allowed only in the I-M, I-H, C-D and H-A districts, added to the height of chain link fences and located above 6½ feet. Barbed wire is limited to no more than three bands, shall be illuminated by exterior area security lighting controlled by an automatic light level switch, and be installed and maintained in good operating condition.
(Ord. No. 35, 2021, § 5(app. A, § 5), 9-21-2021)
Ask a question about Greeley law
Corpus searches the Greeley sections it holds and shows the ones that match, with their citations. Free, no sign-in.
