§ 20.20.020 — Specific standards
Code of Ordinances of the City of Longmont, Colorado (Codified through Ordinance No. O-2026-39, enacted June 23, 2026 (Supp. No. 9)) · Longmont Code of Ordinances § 20.20.020
Corpus is an independent public-information project, not the official City of Longmont website. Stable reference: corpuslaw.us/code/1c31858f-14d3-4135-ac52-064a4a4e0c9d
Sec. 20.20.020. - Specific standards.
In all special flood hazard areas where base flood elevation data has been provided as set forth in: (i) section 20.12.020; (ii) section 20.16.020.G; or (iii) section 20.20.060, the following provisions are required: A. Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), elevated to one foot above the base flood elevation. Upon completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered state professional engineer, architect, or land surveyor. Such certification shall be submitted to the floodplain administrator. B. Nonresidential construction. 1. With the exception of critical facilities, outlined in section 20.20.080, new construction and substantial improvements of any commercial, industrial, or other nonresidential structure shall either have the lowest floor (including basement), electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), elevated to one foot above the base flood elevation or, together with attendant utility and sanitary facilities, be designed so that at one foot above the base flood elevation, the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. 2. A registered state professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this section. Such certification shall be maintained by the floodplain administrator, as proposed in section 20.16.030. C. Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered state professional engineer or architect or meet or exceed the following minimum criteria: 1. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. 2. The bottom of all openings shall be no higher than one foot above grade. 3. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. D. Manufactured homes. All manufactured homes that are placed or substantially improved within zones A1-30, AH, and AE on the community's FIRM on sites: (i) outside of a manufactured home park or subdivision; (ii) in a new manufactured home park or subdivision; (iii) in an expansion to an existing manufactured home park or subdivision; or (iv) in an existing manufactured home park or subdivision on which manufactured home has incurred substantial damage as a result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home, electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), is elevated to one foot above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. All manufactured homes placed or substantially improved on sites in an existing manufactured home park or subdivision within zones A1-30, AH and AE on the community's FIRM that are not subject to the provisions of the above subsection, shall be elevated so that either: 1. The lowest floor of the manufactured home, electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities (including ductwork), is one foot above the base flood elevation; or 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. E. Recreational vehicles. All recreational vehicles placed on sites within zones A1-30, AH, and AE on the community's FIRM must: 1. Be on the site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use; or 3. Meet the permit requirements of section 20.16.030, and the elevation and anchoring requirements for manufactured homes in subsection D of this section. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices and has no permanently attached additions. F. Prior approved activities. Any activity for which a floodplain development permit was issued by the city or a CLOMR was issued by FEMA prior to December 18, 2012, may be completed according to the standards in place at the time of the permit or CLOMR issuance and will not be considered in violation of this title if it meets such standards.
(Code 2009, § 20.20.020; Ord. No. O-2012-79, § 1, 12-4-2012)
Ask a question about Longmont law
Corpus searches the Longmont sections it holds and shows the ones that match, with their citations. Free, no sign-in.