§ 15.16.020 — Modifications to International Mechanical Code, 2024 Edition

Municipal Code of the City of Loveland, Colorado (Codified through Ordinance No. 6832, enacted June 2, 2026. (Supp. No. 14)) · Loveland Municipal Code § 15.16.020

Corpus is an independent public-information project, not the official City of Loveland website. Stable reference: corpuslaw.us/code/29325bf6-ea20-4773-bbc5-de6b957ee507

15.16.020 - Modifications to International Mechanical Code, 2024 Edition.

The International Mechanical Code, 2024 Edition, adopted in this chapter, is modified as follows: A. Section 101.1 - Title - is amended to read as follows: These regulations shall be known as the Mechanical Code of the City of Loveland, hereinafter referred to as "this code" or "mechanical code." B. Section 103 - Code Compliance Agency - is deleted in its entirety. See LMC 15.04.050. C. Section 104 - Duties and powers of the code official - is deleted in its entirety. See LMC 15.04.050. D. Section 105.4 - Permit issuance - is deleted in its entirety. See LMC 15.04.090. E. Section 106.1 - Construction documents - is amended to read as follows: Construction documents, engineering calculations, diagrams and other data shall be submitted electronically with each application for a permit. The code official shall require construction documents, computations and specifications to be prepared and designed by a registered design professional where required by state law. Where special conditions exist, the code official is authorized to require additional construction documents to be prepared by a registered design professional. Construction documents shall be drawn to scale and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that the work conforms to the provisions of this code. Construction documents for buildings more than two (2) stories in height shall indicate where penetrations will be made for mechanical systems, and the materials and methods for maintaining required structural safety, fire-resistance rating and fire blocking. F. Section 108 - Fees - is deleted in its entirety. See LMC 15.04.190. G. Section 112 - Means of appeals - is deleted in its entirety. See LMC 15.04.210. H. Section 113 - Board of appeals - is deleted in its entirety. See LMC 15.04.210. I. Section 114 - Violations - is deleted in its entirety. See LMC 15.04.230. J. Section 202 - General Definitions - is amended by the addition of the following definition of "Temporary": Temporary. A time period no longer than 180 days. K. Section 507 - Commercial Kitchen Hoods - is amended by the addition of a new section 507.4 and subsection 507.4.1 to read as follows: 507.4: Performance test. A performance test shall be conducted upon completion and before final approval of the installation of a ventilation system serving commercial cooking appliances. The test shall verify the rate of exhaust airflow required by Section 507.5, makeup airflow required by Section 508 and proper operation as specified in this Chapter. The permit holder shall furnish the necessary test equipment and devices required to perform the tests. 507.4.1: Capture and containment test. The permit holder shall verify capture and containment performance of the exhaust system. This field test shall be conducted with all appliances under the hood at operating temperatures, with all sources of outdoor air providing makeup air for the hood operating and with all sources of recirculated air providing conditioning for the space in which the hood is located operating. Capture and containment shall be verified visually by observing smoke or steam produced by actual or simulated cooking, such as that provided by smoke generators. L. Section 1001 - General - is amended by the addition of a new subsection 1001.2 to read as follows: 1001.2 Operations and maintenance of boilers and pressure vessels. Boilers and pressure vessels shall be operated and maintained in conformity with requirements for adequate protection of the public according to nationally recognized standards. The State of Colorado Boiler Inspector shall notify the owner or the authorized representative of defects or deficiencies, which shall be properly and promptly corrected. M. Section 1011 - Tests - is amended to read as follows: An installation for which a permit is required shall not be put into service until it has been inspected and approved. It is the duty of the owner or his or her authorized representative to notify the State of Colorado Boiler Inspector or an authorized alternate that the installation is ready for inspection and test. The results of such test shall be submitted to the building official for acceptance.

(Ord. No. 6810, § 1, 6-2-2026; Ord. No. 6587, § 1, 11-15-2022; Ord. No. 6374, § 1, 12-15-2020)

Ask a question about Loveland law

Corpus searches the Loveland sections it holds and shows the ones that match, with their citations. Free, no sign-in.