15.18.020 - Modifications to International Fuel Gas Code, 2024 Edition.
The International Fuel Gas Code, 2024 Edition, adopted in this chapter, is modified as follows: A. Section 101.1 - Title - is amended to read as follows: These regulations shall be known as the Fuel Gas Code of the City of Loveland, hereinafter referred to as "this code" or "fuel gas code." B. Section 103 - Code Compliance Agency - is deleted in its entirety. See LMC 15.04.050. C. Section 104 - Duties and powers of the code official - is deleted in its entirety. See LMC 15.04.050. D. Section 106.5 - Permit issuance - is deleted in its entirety. See LMC 15.04.190. E. Section 109 - Fees - is deleted in its entirety. See LMC 15.04.190. F. Section 115 - Violations - is deleted in its entirety. See LMC 15.04.230. G. Section 113 - Means of appeals - is deleted in its entirety. See LMC 15.04.220. H. Section 202 - General Definitions - is amended by the addition of the following definition of "Temporary": Temporary. A time period no longer than 180 days. I. Section 402.7.1 - Operation below negative five degrees Fahrenheit (-5°F) (-21°C) - is amended to read as follows: LP-gas systems designed to operate below negative five degrees Fahrenheit (-5°F) (-21°C) or with butane or a propane-butane mix shall be designed to either accommodate liquid LP-gas or prevent LP-gas vapor from condensing into a liquid. Equipment burning liquefied petroleum gas (LPG) shall not be located in a pit, basement, under floor space, below grade, attic or similar location where vapors or fuel may unsafely collect. Liquid petroleum gases, including construction and temporary heating shall only be installed per the adopted fire code, manufacturer's specifications and listing of the appliance(s). J. Section 406.4.1 - Test pressure - is amended to state as follows: These inspections shall include a determination that the gas piping size, material, and installation meet the requirements of this code and shall be made after all piping authorized by the permit has been installed and before any portions thereof which are to be covered or concealed are so concealed and before any fixture, appliance, or shutoff valve has been attached thereto. This inspection shall include an air, CO2 or nitrogen pressure test, at which time the gas piping shall stand not less than ten (10) pounds per square inch (68.9 kPa) gauge pressure, or at the discretion of the building official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge. Test pressures shall be held for a length of time satisfactory to the building official, but in no case for less than fifteen (15) minutes, with no perceptible drop in pressure. K. Section 406.4.2 is amended to state as follows: For piping two and a half inches (2.5") and larger, welded piping, and for piping carrying gas at pressure in excess of fourteen (14) inches (356 mm) water column pressure, the test pressure shall not be less than sixty (60) pounds per square inch (413.4 kPa) and shall be continued for a length of time satisfactory to the building official, but in no case for less than fifteen (15) minutes. These tests shall be made using air, CO2, or nitrogen pressure only and shall be made in the presence of the building official. All necessary apparatus for conducting tests shall be furnished by the permit holder. Test gauges used in conducting tests shall comply with Chapter 4 of this code. L. Section 503.4.1 - Plastic Piping - is amended to state as follows: Where plastic piping is used to vent an appliance, the appliance shall be listed for use with such venting materials and the appliance manufacturer's installation instructions shall identify the specific plastic piping material. The plastic pipe venting materials shall be labeled in accordance with the product standards specified by the appliance manufacturer or shall be listed in accordance with UL 1738. Where installed as an exhaust vent for a gas fired water heater or any gas-fired appliance the new plastic pipe shall be tested with 5 psi maximum air pressure at the time of inspection prior to being connected to the water heater or gas fired appliance.
(Ord. No. 6811, § 1, 6-2-2026;Ord. No. 6588, § 1, 11-15-2022; Ord. No. 6375, § 1, 12-15-2020)
Ask a question about Loveland law
Corpus searches the Loveland sections it holds and shows the ones that match, with their citations. Free, no sign-in.