§ 16-8-6 — Maintenance, record keeping and inspections
Code of Ordinances of the City of Pueblo, Colorado (Codified through Ordinance No. 11209, adopted June 25, 2026 (Supp. No. 110)) · Pueblo Code of Ordinances § 16-8-6
Corpus is an independent public-information project, not the official City of Pueblo website. Stable reference: corpuslaw.us/code/a1d6aae1-1a57-40b1-81f6-a2942d07a5c8
Sec. 16-8-6. - Maintenance, record keeping and inspections.
(a) Maintenance. (1) Each food and engine service facility shall be responsible for the costs of installing, inspecting, pumping, cleaning and maintenance of a grease interceptor or sand interceptor. Pumping services and disposal shall include the complete removal of all contents, including floating materials, wastewater and bottom sludges and solids. Cleaning shall include scraping excessive solids from the walls, floors, baffles and all pipe work. It shall be the responsibility of each facility to inspect its grease interceptor, or sand interceptors during the pumping procedure to ensure that it is properly cleaned and that all internal fittings and fixtures are in working condition and functioning properly. The solids, grease, and sand shall be disposed of in a solid waste disposal facility authorized to receive such waste or it may be recycled. No grease, solid materials removed or sand and oil shall be returned to any grease interceptor, sand interceptor, private sewer line, or to any portion of the City's wastewater collection system or the City Water Reclamation Facility without prior written permission from the Wastewater Department. (2) Each food or engine service facility may contract with a grease hauler who has been issued a permit by the City for cleaning services or it may develop a written protocol and perform its own cleaning and maintenance procedures. (3) Each food and engine service facility shall have its interceptor(s) pumped according to the following criteria for each facility: a. Food service facilities shall determine frequency of pumping of its grease interceptor(s) according to the following criteria; 1. Food service grease interceptors shall be pumped no less than once per month; or 2. When the floatable grease layer exceeds six (6) inches in depth as measured by an approved dipping method; or 3. When the settled solids layer exceeds eight (8) inches in depth as measured by an approved dipping method; or 4. When the total volume of captured grease and solid material displaces more than 20% of the capacity of the interceptor as calculated using an approved dipping method; or 5. When the interceptor is not retaining/capturing oils and greases; or the removal efficiency of the device, as determined through sampling and analysis, is less than eighty percent (80%). b. Engine service facilities shall determine their frequency of pumping according to the following criteria; 1. Sand interceptors shall be pumped no less than once every quarter for truck washes, heavy equipment washes, and commercial washes and no less than once every year for all other users; or 2. If the total accumulation of solids, debris and oil exceeds twenty-five percent (25%) of either the total capacity or twenty-five percent (25%) of the capacity of any one (1) chamber. (4) Any chemicals, enzymes, emulsifies, live bacteria or other grease cutters or additives used by a food or engine service facility or the grease hauler must be approved by the Wastewater Director prior to their use. MSDS sheets and manufacturer instructions for use shall be submitted to the City together with a written statement outlining the proposed use of the additive(s) by the facility or grease hauler. Based upon the information received and any other information obtained from the potential user or supplier, the City shall allow or deny the use of the additive in writing. Permission to use any specific additive may be withdrawn by the City at any time. In no circumstance shall the use of additives alone take the place of regular pumping and cleaning. (b) Record Keeping. (1) Each food and engine service facility shall keep accurate records of all services performed on a grease and sand interceptor including the identification of the person or persons performing the services, the date and time of the cleaning, maintenance, repairs or other services performed. The records shall be available for inspection by the GMP official upon request. (2) Each food and engine service facility shall submit a semi-annual report to the City on a form provided by the City. Reports shall be submitted on or before the last day of June and December in each year. Each report shall record the number of times a grease interceptor or sand interceptor has been cleaned since the last report and shall indicate the volume of liquids and solids removed on each occasion and the name and address of the grease hauler. If a variance has been granted under Section 16-8-7 of this Chapter, the alternate cleaning frequency shall also be reported. Each report shall also note any repairs that have been made to a grease interceptor, or sand interceptor including the dates that these repairs were made. Reports shall be submitted to the Pretreatment Division of the Wastewater Department and shall be deemed to be in violation of this requirement if they are received by the City more than thirty (30) days after the deadline for submission. All maintenance records are required to be kept for a minimum of three (3) years. (c) Inspections. (1) The City may conduct inspections of any facility with or without notice for the purpose of determining applicability and/or compliance with any requirement of this Chapter. (2) Inspection results will be provided in writing to the facility.
(Ord. No. 8871 §1, 5-26-15)
Ask a question about Pueblo law
Corpus searches the Pueblo sections it holds and shows the ones that match, with their citations. Free, no sign-in.