For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17-4-49 — Building and site design standards for Industrial Zone Districts

Code of Ordinances of the City of Pueblo, Colorado (Codified through Ordinance No. 11209, adopted June 25, 2026 (Supp. No. 110)) · Pueblo Code of Ordinances § 17-4-49

Corpus is an independent public-information project, not the official City of Pueblo website. Stable reference: corpuslaw.us/code/90de7b56-27b5-4a5c-a4be-e5061688179a

Sec. 17-4-49. - Building and site design standards for Industrial Zone Districts.

(a) General Intent. The Building and Site Design Standards for Industrial Zone Districts are intended to promote the health, safety, general welfare and visual appearance of industrial development; enhance economic vitality; promote street and neighborhood character; and to strengthen the health and well-being of the community by providing aesthetic improvements and opportunities for social interaction within urbanized industrial areas. Industrial zoned development sites within designated high visibility areas, as identified in Figure 4.49.1, are required to provide a higher degree of architectural improvements than industrial zoned sites in lower visibility areas. Figure 4.49.1 delineates high visibility sites that are currently zoned industrial and those that could potentially be zoned industrial in the future, all other industrial zoned properties are considered low visibility areas or sites. An application for a variance, of specific requirements within this Section may be considered by the Zoning Board of Appeals under the provisions of Section 17-5-34 through Section 17-5-38 of the Pueblo Municipal Code. [image omitted; see the official code] Figure 4.49.1 (b) Applicability. (1) Provisions of this Section shall apply to all industrial zoned properties for which an application for development has been submitted after the effective date of the approval of these standards within high visibility and low visibility areas identified on the attached Figure 4.49.1 unless otherwise specified. (2) Provisions of this Section shall apply to the following: a. Construction of a New Structure. b. Additions to a building that increases the total square footage of the structure by thirty-five percent (35%) or more. If the addition equals or exceeds thirty-five percent (35%) of the existing structure, the original structure must be brought into compliance with, and the new addition must adhere to, the building and site design standards for Industrial Zone Districts. (c) Building Orientation. (1) Primary Facades: A building's primary façade(s) includes all façade(s) adjacent to public rights-of-way. A primary façade shall serve as the main access point to a building or building unit. In situations where it is not possible for a building's primary entrance to be located adjacent to a public right-of-way, façade(s) adjacent to a major access drive and/or primary parking area serve as the primary façade(s). A parcel or lot may have multiple primary facades depending upon the location of adjacent rights-of-way and the structure's primary entrance. (2) Secondary Façades: A building's secondary façades shall consist of all other facades that are not defined as a primary façade. [image omitted; see the official code] Mid-Block Orientation (d) Screening. (1) Chain link fencing, with or without screening attachments, is not an acceptable screening mechanism along primary facades. Chain link fencing may be used for screening or security purposes along secondary facades, as long as the fence is set back from the right-of-way and is not visually obtrusive. (e) Design Standards High Visibility Areas. These standards apply to all industrial zoned properties within high visibility areas identified on the attached Figure 4.49.1 unless otherwise specified. (1) Building Architectural Standards. a. Requirement for four-sided design: a building's special architectural features and treatments shall not be restricted to a single façade. All sides of a building open to view, whether viewed from public or private property, shall display appropriate architectural interest as required in Subsection 17-4-49(e)(1)c.1. b. Building entry and office space: entry and office spaces shall be distinguished from the building mass. c. Building mass and form: large, square, "box-like" structures with unbroken flat walls are not an acceptable form. Architectural elements with smaller forms stepping outwards and down shall be encouraged. The design of all buildings shall employ a variety of elements as required in Subsection 17-4-49(e)(1)c.1. 1. An industrial building's primary façades shall incorporate a minimum of five (5) of the following elements. Secondary facades shall incorporate a minimum of two (2) of the following elements: i. Change in color; ii. Graphical patterning; iii. Changes in texture or material; iv. Projections, recesses and reveals; v. Windows and fenestration; vi. Awnings or canopies; vii. Arcades and pergolas; viii. Towers; ix. Gable projections; x. Horizontal or vertical breaks; or xi. Other similar techniques. d. Building roofs: all roof areas visible from any public or private right-of-way, shall be surfaced with attractive and durable materials. 1. Flat roofs with less than a 1/12 roof pitch, shall incorporate roof treatments that break up the roof plain, which may include a variety of vertical, horizontal or step-out treatments. 2. Pitched roofs shall incorporate overhanging eaves that extend twelve (12) inches from the facade; varying rooflines that may include dormers, multiple heights, slopes, and/or projections. (2) Building Site Development Standards. a. Service and loading areas: service and loading areas shall not be located along primary facades. The Administrative Official has the authority to allow service and loading areas along primary facades in situations where a documented physical hardship exists, precluding the construction of the service and/or loading areas from being constructed on a secondary façade. b. Accessory buildings: all accessory buildings visible from a public street shall be similar in color and material to the principle structure on a site. c. Outdoor storage areas: all outdoor storage areas must be located behind or to the side of the principle structure along secondary facades or within the rear yards of the site. Outdoor storage areas shall be fully screened with closely planted evergreen landscape material, architecturally compatible material or complimentary opaque screening materials that provide visual interest. d. Refuse and/or recycling containers: refuse and/or recycling collection containers shall not be visible from the public rights-of-way, pedestrian areas and adjacent residential properties. Refuse and/or recycling containers shall be fully screened with closely planted evergreen landscape material, architecturally compatible material or complimentary opaque screening materials that provide visual interest. e. Parking: parking areas located adjacent to the primary facade shall be used for passenger vehicles only. All commercial vehicles shall be parked in the rear or side portions of the property. If the property has multiple frontages, the higher classification roadway shall be considered the front with respect to the location of parking. (3) Mechanical Equipment Screening. a. Roof-mounted mechanical equipment: equipment whether located on flat or pitched roofs, shall be completely screened from the ground level and the public right-of-way by parapet walls or structural features that are consistent with the architectural elements, materials, and colors of the primary structure. b. Wall-mounted mechanical: mechanical and electrical equipment mounted on primary and secondary facades are discouraged. If equipment is mounted on a wall, the equipment should be screened by dense evergreen foliage or other architecturally compatible screening mechanisms and be mounted on a secondary façade. Wall-mounted mechanical equipment on secondary facades shall be painted to match the color of the subject building or screened by other acceptable devices. c. Ground mounted mechanical equipment: ground-mounted mechanical equipment, excluding transformers, adjacent to primary facades shall be screened through use of walls, earth berms, dense evergreen foliage or other acceptable screening devices. Secondary facades have no screening requirements. (4) Landscaping. Industrial site landscaping will be used to enhance compatibility of adjacent uses as well as enhance the aesthetic character of the industrial site. Industrial zoned properties, including I-3, Heavy Industrial properties, in the designated high visibility areas, shall comply with the requirements of Section 17-4-7(b)(2), Landscape Performance Standard with the following exceptions: a. Industrial site improvements: all portions of the industrial parcel, adjacent street rights-of-way, and alleys upon which it fronts shall be landscaped, paved, fenced, planted or covered by buildings, so that no dust will blow off the site and no soil or debris will be washed upon the sidewalks, alleys or streets from the parcel in the event of a rainstorm. b. New freestanding or monument sign: the installation of a new freestanding or monument sign, on a previously developed site, shall require compliance with sign landscaping in lieu of full landscaping as required by Section 17-4-7 of this Title. Sign landscaping shall consist of a twenty (20) foot wide landscaped area, around the entire perimeter of the sign, and include a mixture of two (2) of the following landscaping elements: trees, shrubs, grasses and boulders to accentuate the sign. The Administrative Official may allow a reduction in the required twenty (20) foot width of the perimeter landscaping, if it can be demonstrated that a development site hardship exists, and appropriate visual appeal is achieved within the reduced width. c. Shade trees: the number of shade trees required by Section 17-4-7(b)(3)a.1. of this Title is reduced to one (1) shade tree for every fifty (50) linear feet of street frontage. d. Parking strips: parking strips may be used in lieu of parking lot islands. The parking strip shall have a minimum width of nine (9) feet and extend the entire length of the parking area and include one (1) shade tree every fifty (50) feet. [image omitted; see the official code] Parking Island/Parking Strip Diagram e. Stormwater drainage and detention: on-site stormwater drainage and detention facilities shall be constructed in compliance with the City's Drainage Criteria Manual (June 9, 1997) and the City's Standard Construction Specifications and Standard Details (March 25, 2005) or as same may be later amended. On-site stormwater facilities are not required to be landscaped with turfgrass if placed behind the building structure and are not visible from public rights-of-way. f. Fencing and screening walls: all fences and screening walls in line with or along primary facades, shall be constructed with decorative blocks, brick, stone, treated wood or ornamental metal. Expanses of screening walls fifty (50) linear feet or greater, shall be broken up with material, plain and elevation changes, which may include curvilinear design, periodic columns, insets, or landscape pockets. Chain link fencing is only permitted to be used along secondary frontages. g. Vehicular circulation and access: on-site vehicular circulation shall have an adequate length of stacking for industrial facilities, including but not limited to loading, docks, gated entrances, and terminals that do not interfere with the movement of vehicular and pedestrian traffic (on or off-site) and minimize vehicular impacts to adjacent properties. (f) Design Standards Low Visibility Areas. Low visibility standards apply to all industrial zoned properties that are not identified as high visibility areas on Figure 4.49.1 unless otherwise specified. (1) Building Architectural Standards. a. Requirement for façade design: a building's special architectural features and treatments in a low visibility area may be limited to primary facades that front a street right-of-way and major access drives. b. Building entry and office space: entry and office spaces shall be distinguished from the building mass. c. Building mass and form: the design of primary facades shall employ a variety of the following elements: textured surfaces, projections, recesses, shadow lines, color, window patterns, overhangs, reveals, three-dimensional cornice treatments, changes in parapet heights and similar architectural features to avoid monolithic primary facades and to emphasize building entries. 1. An industrial building's primary façade shall incorporate a minimum of three (3) of the following elements: i. Change in color; ii. Graphical patterning; iii. Changes in texture or material; iv. Projections, recesses and reveals; v. Windows and fenestration; vi. Awnings or canopies; vii. Arcades and pergolas; viii. Towers; ix. Gable projections; x. Horizontal or vertical breaks; or xi. Other similar techniques. (2) Building Site Development Standards. a. Service and loading areas: service and/or loading areas are encouraged to be located along secondary facades. If a service and/or loading area is located along a primary façade, the service and/or loading area shall be incorporated into the overall architectural design of the primary structure. b. Mechanical equipment: mechanical equipment attached to a building is encouraged to be placed on the roof or along secondary facades. All mechanical equipment placed on primary facades shall be properly screened with architecturally compatible materials or materials that provide visual interest. c. Outdoor storage areas: all outdoor storage areas must be located behind or to the side of the principle structure along secondary facades or within the rear yards of the site. d. Refuse and or recycling containers: refuse and or recycling collection containers shall not be visible from the public rights-of-way, pedestrian areas and adjacent residential properties. (3) Landscaping. Low visibility area industrial landscaping will be used to enhance compatibility of adjacent uses as well as enhance the aesthetic character of the industrial site. I-1, Light Industrial, and I-2, Industrial District, zoned properties in the designated low visibility areas, are not required to comply with Section 17-4-7 Landscape Performance Standards; however, these sites are required to comply with the following landscape standards: a. Industrial site improvements: all portions of the industrial parcel, adjacent street rights-of-way, and alleys upon which it fronts shall be landscaped, paved, fenced, planted or covered by buildings, so that no dust will blow off the site and no soil or debris will be washed upon the sidewalks, alleys or streets from the parcel in the event of a rainstorm. b. New freestanding or monument sign: the installation of a new freestanding or monument sign, on either a newly or previously developed site, shall require compliance with sign landscaping consisting of a twenty (20) foot wide landscaped area, around the entire perimeter of the sign, and include a mixture of two (2) of the following landscaping elements: trees, shrubs, grasses and boulders to accentuate the sign. The Administrative Official may allow a reduction in the required twenty (20) foot width of the perimeter landscaping, if it can be demonstrated that a development site hardship exists, and appropriate visual appeal is achieved within the reduced width. c. Driveway entrance landscaping: a landscape area, with a minimum width of ten (10) feet shall be established adjacent to both sides of a driveway entrance. The landscape area shall include a mixture of trees, shrubs, grasses, and ground cover. Living ground cover is encouraged but not required. d. On-site stormwater drainage and detention facilities: on-site stormwater drainage and detention facilities shall be constructed in compliance with the City's Drainage Criteria Manual (June 9, 1997) and the City's Standard Construction Specifications and Standard Details (March 25, 2005) or as same may be later amended. On-site stormwater facilities are not required to be landscaped with turfgrass if placed behind the building structure and not visible from any streets adjacent to the primary or secondary facades.

(Ord. No. 9381 §5, 11-26-18)

Ask a question about Pueblo law

Corpus searches the Pueblo sections it holds and shows the ones that match, with their citations. Free, no sign-in.