§ 17-4-5 — Schedule of District Regulations (Part IV, Nonresidential)
Code of Ordinances of the City of Pueblo, Colorado (Codified through Ordinance No. 11209, adopted June 25, 2026 (Supp. No. 110)) · Pueblo Code of Ordinances § 17-4-5
Corpus is an independent public-information project, not the official City of Pueblo website. Stable reference: corpuslaw.us/code/d844f14b-0124-4c1a-983a-e8d2972aaf47
Sec. 17-4-5. - Schedule of District Regulations (Part IV, Nonresidential).
The applicant shall submit proof that he or she can or will meet the applicable performance standards listed below. (1) O-1, B-1, B-2, B-3, B-4 and CCN Districts; performance standards. a. All portions of the land area of the parcel and the adjacent street rights-of-way and alleys upon which it fronts shall be landscaped, graded, paved, fenced, planted or covered by buildings, so that no dust will blow off the site and no soil or debris will be washed upon the sidewalks, alleys or streets from the parcel in the event of a rainstorm. b. All outdoor storage areas shall be enclosed by tight fencing, walls or closely planted landscape material, sufficient in height to totally obscure the storage areas as seen from a height of five (5) feet along the property line, and such areas and all others shall be constructed, used and maintained to have an orderly appearance at all times. c. No sound, smoke, odor, vibration, dust, glare or heat shall be measurable beyond the outer boundaries of the parcel. d. In a B-3 zone district no unauthorized sign, signal, marking or device shall be placed, maintained or displayed which (1) is located in the right-of-way of any street, alley or highway, or encroaches into the air space above the right-of-way; (2) flashes or blinks; (3) uses the colors of red, amber or green in such manner as to be confused with an official traffic control device or railroad sign or signal; or (4) violates the Model Traffic Code for Colorado Municipalities, Section 15-12, "Unauthorized signs, signals, or markings." e. In an O-1 Zone District, only business wall signs and permanent window signs shall be permitted and shall be regulated as follows: 1. No wall sign shall extend more than fifteen (15) feet above building grade. 2. Only one (1) business wall sign shall be permitted and displayed to each street frontage. 3. Window signs shall not have a sign area in excess of ten percent (10%) of the area of the window to which it is affixed. 4. The combined total sign area of the wall sign and window signs displayed to a street shall not exceed two (2) times the square root of the property's frontage onto said street. Examples are as follows: Frontage | Square Root | Total Sign Area 50 feet | 7.1 | 14.2 sq. feet 75 feet | 8.7 | 17.4 sq. feet 100 feet | 10.0 | 20.0 sq. feet 5. Signs shall be illuminated solely by stationary, shielded light sources directed to the sign; or by internal light sources producing not more than one (1) foot-candle of illumination at a distance four (4) feet from the sign. 6. Signs shall not: (a) flash, blink, be animated or emit noise; or (b) violate Section 15-12, "Unauthorized signs, signals, or markings" of the Model Traffic Code for Colorado Municipalities as adopted by Section 15-1-1 of this Code. f. In a CCN, setback dimensions for residential structures and uses shall be determined as described below. However, the Zoning Administrator may review and approve setback reductions when the precedent pattern of development on the subject and immediately adjacent blocks is less than the current requirement. It will be the responsibility of the party requesting the reduction to provide a survey, or other suitable documentation, which verifies the existing setbacks on the adjacent properties. The following yard setback requirements shall apply within the Commercial Charter Neighborhood District: 1. The front yard setback for all residential buildings shall be the average of the existing building setbacks on adjacent lots. If there is only one (1) adjacent lot with a building, the setback shall be equal to its setback. If both adjacent lots are vacant, the setback shall be the average of all existing building setbacks on the block. If there are no houses on the block, the setback shall be twenty-five (25) feet. 2. Side yard setbacks for one- and two-family residential units and their accessory structures on lots thirty-five (35) feet or fewer in width shall be three (3) feet. Projections shall not extend to a point closer than two (2) feet from the property line. 3. Side yard setbacks for other buildings: five (5) feet, except that no side yard setback is required between two (2) commercial buildings. 4. Two (2) one-family residences may be constructed on two (2) separate lots, connected to each other (zero [0] setback) on one (1) side with a side yard setback of five (5) feet on the other side, provided that the residences are built at the same time. 5. Side yard setbacks for lots greater than thirty-six (36) feet in width: five (5) feet. g. CCN performance standards. 1. Outdoor storage. The following provisions apply to all outdoor storage except designated off-street parking areas and lots used to display vehicles that are immediately available for sale or rent. (a) In addition to meeting the provisions of the CCN district above, the wall or fence surrounding the storage area shall be kept in a clean, neat and painted condition, and free of graffiti. Fencing made of chain links with slats, salvage materials such as plywood, metal or fiberglass roofing materials or attached fabric materials to existing fences are prohibited. (b) Outdoor storage shall be confined to the rear of the main structure or the rear two-thirds (⅔) of the site, whichever is more restrictive. (c) All gates to access the storage area shall swing inwardly or slide sideways. The gates shall be kept closed when not in use except that the gate may remain open during business hours if the interior or contents of the storage yard cannot be seen from residential areas and public streets. (d) If the storage area is adjacent to any residential zone district, no items shall be stored closer than five (5) feet from the property line. (e) The provisions of Section 17-4-28, relating to the parking and storage of certain vehicles, shall apply to all parcels and lots in the CCN district. (f) Outdoor storage on any vacant parcel or lot is prohibited. (g) Building materials for construction on the same lot may be stored outdoors on the lot provided that a valid building permit is in effect. 2. Alleys. (a) Backing into an alley from parking lots and off-street parking spaces is allowed. (b) Any new construction, expansion of a use or building or home improvements shall not require the applicant to pave any or all of any alley. The applicant, however, shall be required to surface the alley with an all-weather, dustproof material to the point where the alley meets the nearest street. (c) Existing alleys may be vacated only for purposes consistent with an adopted neighborhood plan and subject to the requirements of applicable law. 3. Curb cuts. The width of new curb cuts shall not exceed twenty (20) feet. New curb cuts should be no closer than twenty-two (22) feet from the nearest existing curb cut to aid traffic circulation and increase the safety of pedestrians. 4. Parking. (a) To promote flexibility in design, preserve existing commercial areas and encourage pedestrian uses, the off-street parking requirements set forth in this Chapter may be reduced or waived by the Zoning Board of Appeals based on existing remote parking access, shared spaces and the magnitude of the parking demand from the proposed project. A parking study may be required from the project proponent. (b) Parking areas shall be located in the rear half of the parcel unless the parking is completely enclosed within the main structure. (c) Surface parking lots shall comply with landscaping and screening requirements of Section 17-4-7 of this Chapter except that any fence, berm or landscaping feature at maturity shall comply with Section 15-3-2 of this Code. 5. The following provisions apply to areas adjacent to minor arterials, collectors and local streets. (a) New drive-through or drive-in uses shall not be allowed. (b) The main entrance to a building shall be from the abutting street. (c) The building façade abutting the street shall have at least thirty percent (30%) of the street-level façade area, as measured from the street level upward a maximum of twelve (12) feet, devoted to display windows or windows affording views into the interior area. (d) Awnings or canopies over display windows, doors and entryways may extend over the sidewalk to not more than two (2) feet inward from the edge of the curb or to the point where they interfere with street trees and shall have a minimum clearance of eight (8) feet above the sidewalk. (e) All mechanical equipment on the roof of buildings shall be architecturally screened or enclosed to blend with the roof surface as seen from public rights-of-way. Solar energy collection panels, wireless communications antennas and satellite dish antennas should be blended into architectural features or incorporated into building designs. (f) Outdoor dining is allowed subject to the requirements of Section 9-10-84 of this Code, and provided that a clear distance (unobstructed width) of four (4) feet is maintained for all sidewalks along public streets. 6. Mixed-use and residential projects. The following provisions are applicable to mixed use projects (projects that combine residential and commercial uses within the same building) and residential-only buildings with three (3) or more dwelling units. (a) Three- to five-family dwelling unit structures shall have a minimum of four thousand five hundred (4,500) square feet of land area or one thousand five hundred (1,500) square feet per dwelling unit, whichever is greater. (b) Six- or more family dwelling unit structures shall have a minimum of eight thousand (8,000) square feet of land area or one thousand (1,000) square feet per dwelling unit, whichever is greater. (c) In calculating the floor area ratio, only fifty percent (50%) of the area devoted to residential uses shall be included. (d) Balconies for residential units may extend for a distance of six (6) feet into a required yard facing a street, provided that the balconies are a minimum of ten (10) feet above the ground level and do not extend into the public right-of-way. (e) Open space shall be provided as follows: 1. Private outside open area for residential units shall provide no fewer than one hundred (100) square feet per dwelling unit. 2. Common outside open area for residential units shall provide no fewer than one hundred (100) square feet per dwelling unit. 3. Residents shall have access to useable outside open area, whether public or private, for recreation and social activities. The design and orientation of these areas shall take advantage of available sunlight and shall be sheltered from the noise and traffic of adjacent streets or other incompatible uses. 4. The common outside open area shall be located conveniently for the majority of dwelling units. 5. Private outside open areas shall be contiguous to the dwelling units they serve, be screened from public view and have a minimum dimension of six (6) feet in any direction. (f) A separate area having a minimum of three hundred (300) cubic feet of private and secure storage space shall be provided for each residential unit. 1. The storage area may be located within a garage, provided that it does not interfere with garage use for automobile parking. 2. Normal closet and cupboard space within the living spaces of the dwelling unit shall not count toward meeting this requirement. (g) All primary ground-floor common entries and individual dwelling unit entries for mixed-use projects fronting on streets shall be oriented to the street, not to the interior or to a parking lot. (h) The residential units in mixed-use projects shall be designed to ensure the security of residents through the provision of secured entrances and exits that are separate from the nonresidential uses. Nonresidential and residential uses shall not have common entrance hallways or common balconies except when one (1) residential unit is located above or behind one (1) commercial space. (i) On-site pedestrian circulation for mixed-use projects shall be continuous and connect various uses on site, as well as connect to off-site transit stops and parking. (j) Security lighting that meets the current City lighting standards shall be used in all parking areas and pedestrian walkways within the residential portions of projects. (k) All mechanical equipment shall be screened from view of the on-site residential units, with the exception of solar energy collection panels, wireless communications antennas and satellite dish antennas. Such screening should be made to appear to be an integrated part of the overall architectural design. (l) The following provisions are required to enhance the compatibility of uses within mixed-use projects: 1. Residential portions of a mixed-use project shall be designed to limit the interior noise caused by the commercial and parking portions of the project to a maximum of forty-five (45) db(A) in any habitable room with windows closed. Proper design may include, but shall not be limited to, building orientation, double or extra-strength windows, wall and ceiling insulation and orientation and insulation of vents. Where it is necessary that windows be closed to achieve the required level, means shall be provided for ventilation or cooling to provide a habitable environment. 2. No use, activity or process within a mixed-use project shall produce continual vibrations or noxious odors that are perceptible without instruments by a reasonable person within the interior of on-site residential units. 3. All exterior lighting shall be adequately controlled and shielded to prevent glare and undesirable illumination to on-site residential units. 7. Guidelines. The City Council may adopt development design guidelines for the CCN district by resolution for different types of uses, structures or other matters to preserve the character of the neighborhood while allowing flexibility in the design and building process. If guidelines are so adopted, the Administrative Official shall review all development for consistency with the intent of the guidelines. If the Administrative Official determines the intent of the guidelines is met, the Administrative Official may approve a building permit or business license application, provided that all other applicable requirements of this Title have been met and complied with. The decision of the Administrative Official may be appealed to the Zoning Board of Appeals pursuant to the provisions of Section 17-5-22 of this Title. A building permit shall not be issued until the Administrative Official has approved the development for compliance with the requirements of the CCN district and the guidelines. (2) I-1 District; performance standards. a. No sound resulting from the industrial or business activity shall be measurable at the outer boundaries of the parcel. b. No vibrations resulting from the industrial or business activity shall be measurable at the outer boundaries of the parcel. c. No odors resulting from the industrial or business activity shall be discernible at the outer boundaries of the parcel. d. No observable smoke shall be emitted. Only electricity, fuel oil or gas shall be used as fuels. e. No dust or dirt resulting from the industrial or business activity shall be discernible beyond the outer boundaries of the parcel. f. No noxious gases resulting from the industrial or business activity shall be discernible beyond the outer boundaries of the parcel. g. No glare or heat shall be discernible beyond the outer boundaries of the parcel. h. All outdoor storage areas shall be enclosed in tight fencing or closely planted landscape material, sufficient in height to totally obscure the storage areas as seen from the height of five (5) feet along the property line, and such areas and all others shall be maintained and constructed to have an orderly appearance at all times. i. The front yard and side yards shall be landscaped and maintained in lawn, rocks, plant material, mosaic or other attractive landscaping materials. (3) I-2 District; performance standards. a. Sounds resulting from the industrial or business activity shall not exceed an intensity of sixty (60) decibels at the outer boundaries of the parcel. b. No vibration resulting from the industrial or business activities shall be measurable at the outer boundaries of the parcel. c. No obnoxious or noxious odors resulting from the industrial or business activities shall be discernible at the outer boundaries of the parcel. d. Smoke emission shall not exceed Number 2 on the Ringelmann Chart. e. No dust, dirt or fly ash shall exceed two-tenths (.2) grain per cubic foot of flue gas at a stack temperature of five hundred degrees (500º) Fahrenheit. f. No noxious gases resulting from the industrial or business activity shall be discernible at the outer boundaries of the parcel. g. No glare or heat shall be discernible beyond the outer boundaries of the parcel. h. Industrial wastes shall be so deposited, stored and transmitted from the parcel as to not be objectionable to adjacent properties or create a public nuisance. i. All outdoor storage areas shall be suitably fenced. (4) BP District; performance standards. a. Performance standards: 1. Noise from industrial, commercial or business activity shall comply with Section 11-1-607 of this Code applicable to light industrial zone districts, provided that if located within three hundred (300) feet of a residential zone district the industrial or business activity shall comply with Section 11-1-607 of this Code applicable to commercial zones. 2. No vibrations resulting from any industrial, commercial or business activity shall be measurable at the outer boundaries of the lot. 3. No odors resulting from any industrial, commercial or business activity shall be discernible at the outer boundaries of the lot. 4. No observable smoke shall be emitted from the parcel. 5. No dust or dirt resulting from any industrial, commercial or business activity shall be discernible beyond the outer boundaries of the lot. 6. No noxious gases resulting from any industrial, commercial or business activity shall be discernible beyond the outer boundaries of the lot. 7. No glare or heat generated from any industrial, commercial or business activity shall be discernible beyond the outer boundaries of the lot. 8. No use that would cause interference with or disrupt utility service including, without limitation, electrical, cable, television or telecommunications services to surrounding properties shall be allowed. 9. Outside storage of debris, rubbish, materials, supplies and equipment shall be enclosed on all sides by a screening wall or solid fence at least six (6) feet, but no more than ten (10) feet, in height. Neither debris, rubbish, materials, supplies nor equipment shall be stacked or stored to a height exceeding the height of the screening wall or fence. b. Dimension standards: 1. Minimum lot site: twenty thousand (20,000) square feet. 2. Minimum setback dimensions: (a) Front yard: twenty-five (25) feet. (b) Side yard: ten (10) feet.* (c) Rear yard: twenty-five (25) feet.* (d) Minimum lot width: one hundred (100) feet. *There shall be no setback limitations for that portion of any lot that abuts property located in business or industrial zone districts. 3. Minimum distance of structures from an existing residential zone: one hundred (100) feet. 4. Maximum percentage of the lot to be covered by buildings or structures: fifty percent (50%). 5. Maximum height of buildings: thirty-five (35) feet for buildings that are within one hundred fifty (150) feet of a residential zone district. The maximum building height may then increase at a rate of twenty-five (25) vertical feet for every additional one hundred (100) horizontal feet (25'/100') that the building is away from a residential zone district. (Example: If a building is 300' away from any residential zone district, the maximum building height shall be (150' distance = 35' height) + (150' additional distance = 37.5' height) = 72.5' height). (5) H-B, HARP-1, HARP-2 and HARP-3 Districts; performance standards. a. Historic Business Zone District (H.B.): 1. Performance standards. (a) No building permit shall be issued nor shall any work be undertaken or commenced to construct, reconstruct, remodel, repair, paint, rehabilitate or in any way alter or modify the exterior of any building in any historic business zone district until the Historic Preservation Commission as established and described in Section 4-14-04 of this Code has reviewed, approved and issued a written certificate of compliance for such work. (b) All exterior additions, alterations and renovations shall be approved by the Historic Preservation Commission prior to commencement of work or before the issuance of a building permit where one is required. (c) All trash shall be stored in a tightly enclosed fenced area of sufficient height to totally obscure the storage area from a height of five (5) feet along any adjacent public right-of-way. All trash storage areas shall be kept and maintained in a neat and orderly appearance at all times. (d) Fencing or screening of vacant lots shall obtain prior approval of the committee and such fencing material shall be constructed of material compatible in color, texture and design with adjacent structures and screening. (e) Rehabilitation reconstruction. All buildings, structures and sites shall be considered products of their own time. Changes which have taken place in the course of time may be reflected in the development of a building; however, all rehabilitation shall preserve the character and distinguishing original qualities of the building, structure, site and surrounding environment. Applicants for a certificate of compliance to perform exterior work shall demonstrate: (1) That no historic material or distinctive architectural feature will be altered or removed. (2) That distinctive stylistic features and skilled craftsmanship that characterize the building, structure or site will be preserved. (3) That deteriorated architectural features shall, wherever possible, be repaired rather than replaced. When replaced, such material shall match the material being replaced as closely as possible in composition, design, color, texture and other qualities. (4) That surface cleaning of the structure will be undertaken with a method that is most likely to preserve the integrity and appearance of the structure. Sandblasting and other cleaning methods that will damage the historic building materials are prohibited. (5) That reinforcement required for structural stability or the installation of life, safety or updated building code requirements shall be concealed wherever possible to avoid concealment of aesthetic or historical qualities. (6) That reconstruction of a portion of a structure will be undertaken only when such work is necessary to reproduce a significant missing feature of a building or structure. (f) Alteration and new construction. Alterations shall not destroy the significant historical, architectural or cultural materials of the building or structure, and shall be constructed in such a manner to preserve the essential form and integrity of the structure. All alterations and new construction shall be compatible with the size, scale, architectural detail and character of the existing building. The following requirements shall apply to all remodeling, renovation, construction and reconstruction of any existing or proposed building or structure: (1) Height: The height of the proposed alteration or addition shall not be twenty-five percent (25%) higher than the average height of buildings or structures within a one-hundred-foot radius of the property. (2) Front setback: Additions or alterations shall not project beyond the uniform existing setback line established by adjoining structures. (3) Side setbacks: Additions and alterations shall maintain the general pattern of spaces between buildings as found within the district. (4) Scale: The addition or alteration shall not be inconsistent with the size of the existing building and its relationship with adjoining structures within the district. (5) Proportion: The proportion and relationship between doors and windows proposed in the addition or alteration shall be compatible with the architectural style and character of the existing structure. New windows and doors shall be of similar size and shape and shall incorporate other facade elements and patterns established in the existing structure. (6) Direction alignment: Window frames, transom windows, first floor display windows, sign boards, moldings and cornices shall align and be compatible with the dominant horizontal and vertical expression of the existing structure. (7) Roof shapes: The design of the roof of the addition or alteration shall be compatible with the architectural style of the existing structure. (8) Architectural detail: Architectural details, including but not limited to material, color and texture shall be compatible with the architectural style of the existing structure. (g) Demolition and removal. It is the intent of this Chapter to discourage, wherever possible, the partial or total demolition of any historically significant building or structure. The committee shall consider the following factors in determining whether to approve the demolition of any building or structure: (1) Whether or not the demolition or removal of such structure would negatively impact an historic business zone district. (2) Whether any beneficial use can be conducted on the property in its present or rehabilitated condition. (3) Whether the property presently or in the future will yield a reasonable economic return to its owner. (4) Whether a licensed engineer or architect, experienced in rehabilitation of structures, has found that the building or structure is unsound and unsuitable for rehabilitation. (h) The City Council may by resolution adopt guidelines to implement the performance standard set forth in Subsection e. above, provided, however, that if any provision of the guidelines conflicts with the provisions of Section 17-4-5 (a), the provisions of Section 17-4-5(a) shall control. 2. Appeals. (a) Any person adversely affected by a decision of the Historic Preservation Commission may appeal such decision to the City Council by filing with the City Clerk, within twenty (20) days after Commission's decision, a written request for review. Such appeal must specify in detail the provisions of the Commission's decision the person contends are arbitrary or capricious or is beyond the jurisdiction of the Commission, and the supporting grounds and reasons together with a copy of the Commission's decision. The City Council shall conduct a hearing to review the provisions asserted to be arbitrary or capricious or beyond the jurisdiction of the Commission, and the supporting grounds and reasons specified in the request for review. The person seeking review and the Commission shall be given written notice of the date, time and place of the review hearing at least ten (10) days before the hearing date. Notice to the person seeking review shall be given by first-class mail, postage prepaid, at the person's address stated in the appeal. No other notice need be given for such a hearing. The City Council may sustain the decision of the Commission if it finds that the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner. If City Council finds the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner, the City Council will remand the appeal to the Commission for a redetermination within thirty (30) days. Such determination shall be limited to and consistent with the City Council's written findings. The appeal hearing shall be conducted as near as practicable according to the procedures set forth in Chapter 7 of Title I of this Code. The Commission's decision will be stayed until the City Council rules on the appeal. (b) Any person adversely affected after the Commission makes a final determination, after a review and decision by City Council, may seek judicial review by the District Court, Pueblo County, Colorado, in the manner provided in Rule 106(a)(4), of the Colorado Rules of Civil Procedure. A complaint seeking such review shall be filed in Pueblo District Court no later than thirty (30) days after the Commission's final decision. b. Historic Arkansas Riverwalk of Pueblo Zone District - One (HARP - 1): 1. No building permit shall be issued nor shall any work be undertaken or commenced to construct, reconstruct, remodel, repair, paint, rehabilitate or in any way alter or modify the exterior of any building in a Historic Arkansas Riverwalk of Pueblo Zone District until the Planning and Zoning Commission has reviewed, approved and issued a written certificate of compliance for such work. 2. Performance standards—Building facades that abut a street right-of-way or parking facility. (a) Area. The provisions of these performance standards apply to those facades of buildings which abut a street right-of-way or parking facility. Other facades of the same buildings may fall under a different set of performance standards. (b) Purpose. The purpose of these performance standards is to ensure a commercial streetscape that reflects and respects the downtown architecture that is found in the Union Avenue Historic District. The architecture of the buildings borrows from the same scale, rhythm and materials of the older buildings without imitating them. This zone district plays the role of both back door and front door to the Historic Arkansas Riverwalk of Pueblo which makes it necessary for the building designs to be succinct, easy to read, inviting and a smooth architectural transition between the Victorian architecture at street level and the more free-flowing architecture facing the Riverwalk. (c) Design objectives. Design objectives for the building facades abutting a street right-of-way or parking lot are to: (1) Complement the traditional architecture design of the Union Avenue Historic District. (2) Provide a smooth visual transition from the street level to the river level. (3) Provide an inviting physical entryway into the HARP. (4) Take on the appearance and function of a specialty retail cluster. (5) Provide a continuity of storefronts located along the sidewalk's edge that creates a pedestrian-oriented shopping environment. (d) Structure mass and orientation. Building orientation shall meet the following conditions: (1) Maximum gross floor area is five (5) times the building footprint. (2) Maximum height is five (5) stories from the river level or seventy (70) feet, whichever is less. (3) There are no setback requirements. The outside building walls are encouraged to be located on the outermost parcel boundaries. (4) Each business located at street grade is required to have at least one (1) direct access to a public walkway at street grade. (5) The building facade abutting the street right-of-way or parking facility shall have at least fifty percent (50%) of the street level floor facade area (measured from the street level upward a maximum of twelve [12] feet) devoted to display window and/or windows affording views into the interior area. (e) Exterior architectural design. Exterior architectural design shall meet the following conditions: (1) Each business adjoining a street right-of-way or parking facility shall have an articulated or marked facade. (2) Each facade shall incorporate traditional facade components such as those seen on Union Avenue, including kickplates, display windows, transom windows, recessed entries, sign panels, parapet caps or cornices. (3) The distinction between upper and lower floors shall be maintained. (4) The first floor is primarily transparent while upper floors are more solid with smaller openings. (5) With the exception of the row of windows directly below the parapet, windows on upper stories shall have double-hung windows that are taller than they are wide. (6) The row of windows directly below the parapet may show a different design or shape than the other exterior windows. (7) Awnings are encouraged to provide depth to the facade and to shade the storefront glass. (8) Naturally ventilated parking on the ground level must be recessed below finish grade by at least fifty percent (50%) of the overall height of that story. (f) Exterior building materials and exterior color. Exterior building materials and exterior color shall meet the following conditions: (1) Brick shall be the predominant building component. Brick color shall be in red tones (within 1997 Summit 500 series or suitable replacement). (2) Where used as the predominant building material, brick shall not be painted. (3) Mortar shall be of a natural, color. (4) Building trim shall be of brick and stone masonry, finished lumber, finished painted metal, ceramic tiles or concrete used as lintels and columns. (5) Colors used for mullions and trim shall be from an accepted commercial historic color palette. (g) Building roofs. Building roofs shall be flat, and mechanical equipment on the roof should not be visible from the highest roadway point of any bridge crossing the HARP. (h) Illumination. All lighting or illumination on the exterior of the building shall conform to Section 17-4-52 of this Chapter concerning outdoor lighting performance standards. (i) Signs. In addition to complying with Section 17-2-1 of this Title and the Uniform Building Code, signs shall meet the following conditions: signs shall comply with the Historic Business Zone District standards for signs or approved by Planning and Zoning Commission. (j) Parking. Due to the desire for downtown development, dual-use opportunities and mass transit, the following off-street parking spaces will be required of each use for properties not owned or controlled by the City: (1) Residential units: One (1) parking space per unit. (2) Retail: One (1) parking space per five hundred (500) gross square feet. (3) Office: One (1) parking space per five hundred (500) gross square feet. (4) Restaurants: One (1) parking space for each five (5) persons of rated occupancy load as established by the edition of the Uniform International or Building Code adopted by City Council. (5) Parking requirements for other uses are listed in Section 17-4-43. (6) Variances: If these parking requirements do not appear reasonable to a specific use or combination of uses, or because of available parking in a public parking facility, the City Council may grant by resolution a variance. The variance may reduce some or all of the required number of parking spaces. In determining a variance to the required number of spaces, the City Council, in addition to other relevant factors, shall consider the following: a) The general planning of the City with respect to land use, density, parking, traffic and parking facilities; b) The availability of adequate parking, both in number of spaces and distance from the intended use; c) The public welfare and interest in the City and surrounding area. The City Council shall determine the number of parking spaces required for the development of each lot. 3. Performance standards—Building facades that abut the Riverwalk grade or a part of the Riverwalk public area. (a) Area. The provisions of these design guidelines apply to the building facades abutting the Riverwalk grade or public area associated with the HARP other than a street right-of-way or parking facility. Other facades on the buildings may fall under a different set of performance standards. (b) Purpose. The purpose of the performance standards for building facades abutting the Riverwalk is to ensure that building facades integrate the HARP's pedestrian areas and event plazas. The facades adjoining the Riverwalk show creativity and uniqueness of design while using elements that will age well and remain interesting over time. (c) Design objectives. Design objectives for the building facades that abut the Riverwalk grade are to: (1) Relate to the river and the pedestrian environment surrounding the river. (2) Relate to events held within the HARP. (3) Open itself to outdoors. (4) Create an environment of celebration. (d) Structure mass and orientation. Building orientation shall meet the following conditions: (1) Maximum gross floor area is five (5) times the building footprint. (2) Maximum height is five (5) stories from the river level or seventy (70) feet, whichever is less. (3) There are no setback requirements. The outside building walls are encouraged to be located on the outermost parcel boundaries. (4) Each business shall have at least one (1) direct access to the public Riverwalk area. (e) Exterior architectural design. Exterior architectural design shall meet the following conditions: (1) Building facades that abut the Riverwalk may use a range of architectural styles as long as the results are visually compatible with the general character of the Riverwalk. (2) Each facade shall incorporate facade components that connect to the outdoors, such as balconies, porches, sunroofs and similar exposures. (3) The second through fifth floor facades shall have a minimum of fifty percent (50%) and maximum of sixty percent (60%) glass. Each floor containing balconies may go up to one hundred percent (100%) glass on that floor's facade. (4) Awnings shall reflect the storefront and/or upper window shapes and dimensions. (5) Translucent lighted awnings are not allowed. (f) Exterior building materials and exterior colors. Exterior building materials and exterior colors shall meet the following conditions: (1) Acceptable primary building materials include brick and stone masonry, lumber and ceramic tiles. (2) Acceptable trim materials include brick and stone masonry, stucco, finished lumber, finished painted metal, ceramic tiles or concrete. (3) If brick is used as the predominant building component, the brick color shall be in red tones (within 1997 Summit Brick and Tile 500 series or equal or comparable alternative). (4) The colors used in building facades are flexible as long as a color scheme for the entire building facade conveys a unified image. (5) Bright colors are reserved for special accents such as to emphasize entryways or to highlight special ornamentation. 4. Appeals. (a) Any person adversely affected by a decision of the Planning and Zoning Commission may appeal such decision to the City Council by filing with the City Clerk, within twenty (20) days after Commission's decision, a written request for review. Such appeal must specify in detail the provisions of the Commission's decision the person contends are arbitrary or capricious or is beyond the jurisdiction of the Commission, and the supporting grounds and reasons together with a copy of the Commission's decision. The City Council shall conduct a hearing to review the provisions asserted to be arbitrary or capricious or beyond the jurisdiction of the Commission, and the supporting grounds and reasons specified in the request for review. The person seeking review and the Commission shall be given written notice of the date, time and place of the review hearing at least ten (10) days before the hearing date. Notice to the person seeking review shall be given by first-class mail, postage prepaid, at the person's address stated in the appeal. No other notice need be given for such a hearing. The City Council may sustain the decision of the Commission if it finds that the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner. If City Council finds the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner, the City Council will remand the appeal to the Commission for a redetermination within thirty (30) days. Such determination shall be limited to and consistent with the City Council's written findings. The appeal hearing shall be conducted as near as practicable according to the procedures set forth in Chapter 7 of Title I of this Code. The Commission's decision will be stayed until the City Council rules on the appeal. (b) Any person adversely affected after the Commission makes a final determination, after a review and decision by City Council, may seek judicial review by the District Court, Pueblo County, Colorado, in the manner provided in Rule 106(a)(4), of the Colorado Rules of Civil Procedure. A complaint seeking such review shall be filed in Pueblo District Court no later than thirty (30) days after the Commission's final decision. c. Historic Arkansas Riverwalk of Pueblo Zone District - Two (HARP - 2): 1. No building permit shall be issued nor shall any work be undertaken or commenced to construct, reconstruct, remodel, repair, paint, rehabilitate or in any way alter or modify the exterior of any building in a Historic Arkansas Riverwalk of Pueblo Zone District until the Planning and Zoning Commission has reviewed, approved and issued a written certificate of compliance for such work. 2. Performance standards. (a) Design objectives. Design objectives for the building facades abutting the Riverwalk are to: (1) Complement the architectural design of the Pueblo Convention Center, City Hall and other nearby buildings. (2) Provide a smooth visual transition from the street level to the Riverwalk level. (3) Provide an inviting physical presence and entryway into the HARP. (4) Establish an appropriate architectural presence along the waterfront. (b) Structure mass and orientation. Building orientation shall meet the following conditions: (1) Roof towers shall not exceed ten percent (10%) of the overall roof area of the structure. (2) Minimum height from the Riverwalk level shall be no less than twenty-five (25) feet or two (2) times the gross floor area of the building footprint, whichever is more. (3) Each building shall provide full access to the Riverwalk and to the closest street right-of-way. (c) Exterior architectural design. Exterior architectural design shall meet the following conditions: (1) Building facades that abut the Riverwalk may use a range of architectural styles as long as the results are visually compatible with the general character of the surrounding buildings. In order to achieve this, masonry designs are encouraged, and flat facades are strongly discouraged as described below. (2) Each facade shall incorporate facade components that connect to the outdoors such as balconies, porches, sunroofs and similar exposures. (3) Windows shall be punched with repetitive shapes with nonreflective glass. (4) Balconies are encouraged for hotel rooms that overlook the Riverwalk and are above the first floor. (5) Naturally ventilated parking on the ground level must be recessed below finish grade by at least fifty percent (50%) of the overall height of that story. (d) Exterior building materials. Exterior building materials and exterior color shall meet the following conditions: (1) The predominant building component shall consist of brick or other natural, durable and attractive building material. (2) If brick is the predominant building material, the color shall be within 1997 Summit Brick and Tile 500 series or equal comparable alternative. (3) Building trim shall be of brick and stone masonry, finished lumber, finished painted metal, ceramic tiles or concrete. (4) Tinted brick mortar is encouraged. (5) Ornamental detailing of wrought iron, tile, stone, brick and terra-cotta is encouraged. (6) The colors used in building facades are flexible as long as a color scheme for the entire building facade conveys a unified image. (e) Roofs shall meet the following conditions: (1) Roofs shall be hip or gabled. (2) Roof color shall be warm earth tone reds. (3) Rooftop mechanical equipment shall be incorporated into the design of the building in order not to be visible from the highest roadway point of a bridge crossing the HARP. (f) Illumination. All lighting or illumination on the exterior of the building shall conform to Section 17-4-52 of this Chapter concerning outdoor lighting performance standards. (g) Signs. In addition to complying with Section 17-2-1 of this Title and the Uniform Building Code, signs shall meet the following conditions: signs shall comply with the Historic Business Zone District standards for signs or approved by Planning and Zoning Commission. (h) Parking. Due to the desire for downtown development, dual-use opportunities and mass transit, the following off-street parking spaces will be required of each use for properties not owned or controlled by the City: (1) Residential units: One (1) parking space per unit. (2) Retail: One (1) parking space per five hundred (500) gross square feet. (3) Office: One (1) parking space per five hundred (500) gross square feet. (4) Restaurants: One (1) parking space for each five (5) persons of rated occupancy load as established by the edition of the Uniform Building Code adopted by City Council. (5) Transient lodging: One (1) per hotel room. (i) Amenities. Mailboxes, TV antennae, satellite dishes, window-mounted air-conditioning units, etc., shall be incorporated into the design of the structure and shall be minimally visible to passersby. 3. Appeals. (a) Any person adversely affected by a decision of the Planning and Zoning Commission may appeal such decision to the City Council by filing with the City Clerk, within twenty (20) days after Commission's decision, a written request for review. Such appeal must specify in detail the provisions of the Commission's decision the person contends are arbitrary or capricious or is beyond the jurisdiction of the Commission, and the supporting grounds and reasons together with a copy of the Commission's decision. The City Council shall conduct a hearing to review the provisions asserted to be arbitrary or capricious or beyond the jurisdiction of the Commission, and the supporting grounds and reasons specified in the request for review. The person seeking review and the Commission shall be given written notice of the date, time and place of the review hearing at least ten (10) days before the hearing date. Notice to the person seeking review shall be given by first-class mail, postage prepaid, at the person's address stated in the appeal. No other notice need be given for such a hearing. The City Council may sustain the decision of the Commission if it finds that the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner. If City Council finds the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner, the City Council will remand the appeal to the Commission for a redetermination within thirty (30) days. Such determination shall be limited to and consistent with the City Council's written findings. The appeal hearing shall be conducted as near as practicable according to the procedures set forth in Chapter 7 of Title I of this Code. The Commission's decision will be stayed until the City Council rules on the appeal. (b) Any person adversely affected after the Commission makes a final determination, after a review and decision by City Council, may seek judicial review by the District Court, Pueblo County, Colorado, in the manner provided in Rule 106(a)(4), of the Colorado Rules of Civil Procedure. A complaint seeking such review shall be filed in Pueblo District Court no later than thirty (30) days after the Commission's final decision. d. Historic Arkansas Riverwalk of Pueblo Zone District - Three (HARP 3): 1. No building permit shall be issued nor shall any work be undertaken or commenced to construct, reconstruct, remodel, repair, paint, rehabilitate or in any way alter or modify the exterior of any building in a Historic Arkansas Riverwalk of Pueblo Zone District until the Planning and Zoning Commission has reviewed, approved and issued a written certificate of compliance for such work. 2. Performance standards. (a) Design objectives. Design objectives for the building facades abutting the Riverwalk are to. (1) Complement the architectural design of the Pueblo Convention Center, City Hall and other nearby buildings. (2) Provide a smooth visual transition from the street level to the river level. (3) Provide an inviting physical entryway into the HARP. (4) Establish an appropriate architectural presence along the waterfront. (b) Structure mass and orientation. Building orientation shall meet the following conditions: (1) Roof towers shall not exceed ten percent (10%) of the overall roof area of the structure. (2) Minimum height from the Riverwalk level shall be no less than fifty-five (55) feet or five (5) times the gross floor area of the building footprint, whichever is more. (3) Each building shall provide full access to the Riverwalk and to the closest street right-of-way. (c) Exterior architectural design. Exterior architectural design shall meet the following conditions: (1) Building facades that abut the Riverwalk may use a range of architectural styles as long as the results are visually compatible with the general character of the surrounding buildings. (2) Each facade shall incorporate facade components that connect to the outdoors, such as balconies, porches, sunroofs and similar exposures. (3) Windows shall be punched with repetitive shapes with nonreflective glass. (4) Balconies are encouraged for hotel rooms that overlook the Riverwalk and are above the first floor. (5) Naturally ventilated parking on the ground level must be recessed below finish grade by at least fifty percent (50%) of the overall height of that story. (d) Exterior building materials. Exterior building materials and exterior color shall meet the following conditions: (1) The predominant building component shall consist of brick, stucco or other natural, durable and attractive building material. (2) If brick is the predominant building material, the color shall be within 1997 Summit Brick and Tile 500 series or equal comparable alternative. (3) Building trim shall be of brick and stone masonry, finished lumber, finished painted metal, ceramic tiles or concrete. (4) Tinted brick mortar is encouraged. (5) Ornamental detailing of wrought iron, tile, stone, brick and terra-cotta is encouraged. (6) The colors used in building facades are flexible as long as a color scheme for the entire building facade conveys a unified image. (e) Roofs. Roofs shall meet the following conditions: (1) Roofs shall be hip or gabled. (2) Roof color shall be warm earth-tone reds. (3) Rooftop mechanical equipment shall be incorporated into the design of the building in order not to be visible from the highest roadway point of a bridge crossing the HARP. (f) Illumination. All lighting or illumination on the exterior of the building shall conform to Section 17-4-52 of this Chapter concerning outdoor lighting performance standards. (g) Signs. In addition to complying with Section 17-2-1 of this Title and the Uniform Building Code, signs shall meet the following conditions: signs shall comply with the Historic Business Zone District standards for signs or approved by Planning and Zoning Commission. (h) Parking. Due to the desire for downtown development, dual-use opportunities and mass transit, the following off-street parking spaces will be required of each use for properties not owned or controlled by the City: (1) Residential units: One (1) parking space per unit. (2) Retail: One (1) parking space per five hundred (500) gross square feet. (3) Office: One (1) parking space per five hundred (500) gross square feet. (4) Restaurants: One (1) parking space for each five (5) persons of rated occupancy load as established by the edition of the Uniform Building Code adopted by City Council. (5) Transient lodging: One (1) per hotel room. (6) Variances: If these parking requirements do not appear reasonable to a specific use or combination of uses, the Traffic Engineer, the Director of Transportation or the applicant may apply to the Planning and Zoning Commission for a variance. The Planning and Zoning Commission shall hold a public hearing and then make its recommendation to the City Council, which shall make the final decision. The variance may reduce some or all of the required number of parking spaces. In determining a variance to the required number of spaces, the Planning and Zoning Commission and the City Council, in addition to other relevant factors, shall consider the following: a) The general planning of the City with respect to land use, density, parking, traffic and parking facilities; b) The availability of adequate parking, both in number of spaces and distance from the intended use; c) The public welfare and interest in the City and surrounding area. The City Council shall determine the number of parking spaces required for each lot and the City Council may, in its discretion, as a condition to the granting of any variance, impose a parking investment fee for each lot not to exceed the amounts set forth in Subsections g)1) and 2) below. (7) Parking investment fees: a) To meet parking requirements, the owner of each lot may provide the required parking on site or within three hundred (300) feet, less right-of-way, or may pay to the City a parking investment fee of eight thousand dollars ($8,000.00) for each required parking space. b) Parking investment fees: All parking investment fees shall be deposited in an interest-bearing account which shall clearly identify that such account is to be used to provide parking areas, facilities or structures within one thousand three hundred twenty (1,320) feet of the lot, less right-of-way, for nonexclusive use by the owner, occupants or users of the lot for which the parking investment fee has been paid. The payment of a parking investment fee shall not preclude the City from charging a fee to park in the parking spaces so provided. (i) Amenities. Mailboxes, TV antennae, satellite dishes, window-mounted air conditioning units and similar items shall be incorporated into the design of the structure and shall be minimally visible to passersby. 3. Appeals. (a) Any person adversely affected by a decision of the Planning and Zoning Commission may appeal such decision to the City Council by filing with the City Clerk, within twenty (20) days after Commission's decision, a written request for review. Such appeal must specify in detail the provisions of the Commission's decision the person contends are arbitrary or capricious or is beyond the jurisdiction of the Commission, and the supporting grounds and reasons together with a copy of the Commission's decision. The City Council shall conduct a hearing to review the provisions asserted to be arbitrary or capricious or beyond the jurisdiction of the Commission, and the supporting grounds and reasons specified in the request for review. The person seeking review and the Commission shall be given written notice of the date, time and place of the review hearing at least ten (10) days before the hearing date. Notice to the person seeking review shall be given by first-class mail, postage prepaid, at the person's address stated in the appeal. No other notice need be given for such a hearing. The City Council may sustain the decision of the Commission if it finds that the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner. If City Council finds the Commission exceeded its jurisdiction or acted in an arbitrary or capricious manner, the City Council will remand the appeal to the Commission for a redetermination within thirty (30) days. Such determination shall be limited to and consistent with the City Council's written findings. The appeal hearing shall be conducted as near as practicable according to the procedures set forth in Chapter 7 of Title I of this Code. The Commission's decision will be stayed until the City Council rules on the appeal. (b) Any person adversely affected after the Commission makes a final determination, after a review and decision by City Council, may seek judicial review by the District Court, Pueblo County, Colorado, in the manner provided in Rule 106(a)(4), of the Colorado Rules of Civil Procedure. A complaint seeking such review shall be filed in Pueblo District Court no later than thirty (30) days after the Commission's final decision.
(1957 Code, App. A, §5(4); Ord. No. 3842, 4-8-74; Ord. No. 8933 §5, 11-23-15; Ord. No. 10643 §§1—4, 1-30-24)
Ask a question about Pueblo law
Corpus searches the Pueblo sections it holds and shows the ones that match, with their citations. Free, no sign-in.