For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17-4-52 — Outdoor lighting performance standards

Code of Ordinances of the City of Pueblo, Colorado (Codified through Ordinance No. 11209, adopted June 25, 2026 (Supp. No. 110)) · Pueblo Code of Ordinances § 17-4-52

Corpus is an independent public-information project, not the official City of Pueblo website. Stable reference: corpuslaw.us/code/c4802756-3bb2-4940-a457-73fa7da34c11

Sec. 17-4-52. - Outdoor lighting performance standards.

The intent of these standards is to focus on the physical effects of outdoor lighting, as well as the effect lighting may have on the surrounding neighborhood in all zone districts. Exterior lighting shall be evaluated in the development review process to ensure that the functional and security needs of the project are met in a way that will not adversely affect the adjacent properties or the surrounding neighborhood. The degree to which exterior night lighting affects a property owner or neighborhood will be examined based upon the light source, level of illumination, hours of illumination and the need for illumination in relation to the effects of lighting on adjacent property owners and the neighborhood. (1) Definitions: a. Color rendering index (CRI) means the measured effect of light on objects. To determine the CRI of a lamp, the color appearances of a set of standard color chips are measured with special equipment under a reference light source with the same correlated color temperature as the lamp being evaluated. If the lamp renders the color of the chips identical to the reference light source, the CRI is one hundred (100). If the color rendering differs from the reference light source, the CRI is less than one hundred (100). A low CRI indicates that some color may appear unnatural when illuminated by the lamp. b. Fixture means luminare. c. Foot-candle means a unit of measure for illuminance. A unit of illuminance on a surface that is everywhere one (1) foot from a uniform point source of light of one (1) candlepower and equal to one (1) lumen per square foot. d. Full cut-off type fixture means a luminare or light fixture that, by design of the fixture housing, does not allow any light dispersion or direct glare to shine above a ninety-degree, horizontal plane from the base of the fixture. e. Glare means the direct light emitting from a luminare that causes reduced vision or momentary blindness. f. High pressure sodium (HPS) means a high intensity discharge lamp where radiation is produced from sodium vapor at relatively high partial pressures. HPS is considered a point source. g. Horizontal illuminance means the measurement of brightness from a light source, usually measured in foot-candles or lumens, which is taken through a light meter's sensor at a horizontal position. h. Lamp or bulb means the light-producing source installed in the socket portion of the luminare. i. Light trespass means light emitted by a luminare that shines beyond the boundaries of the property on which the luminare is located. j. Low-pressure sodium (LPS) means a discharge lamp where the light is produced by radiation from sodium vapor at a relatively low partial pressure. LPS is a tube source and is a monochromatic light. k. Luminare means the complete lighting system, including the lamp and fixture. l. Metal-halide lamp means a high intensity discharge lamp where the light is produced by radiation from metal-halide vapors. m. Mounting height means the overall height of the fixture or lamp above the ground. n. Photometry means the quantitative measurement of light level and distribution. o. Security purpose lighting means reduced lighting levels as per Subsection 17-4-52(2)(j), which do not exceed 0.5 foot-candles. p. Shielding means that no light rays are emitted by a fixture above the horizontal plane running through the lowest point of the fixture where light is emitted. q. Sky glow means the result of scattered light in the atmosphere above urban areas and the haze or glow of light that currently surrounds populated areas and reduces the ability to review the nighttime sky. r. Uniformity ratio (UR) means the average level of illumination in relation to the lowest level of illumination for a given area. Example: UR ratio = 4:1 for the given area, the lowest level of illumination, one (1) should be no more than four (4) times the average level of illumination. s. Uplighting means any source that distributes illumination above a ninety-degree horizontal plane. The following images at Figure 5 depict fixtures that do not pollute the sky and neighboring properties with their light spill. Such fixtures are energy-efficient; the maximum amount of generated light is projected onto the area they are intended to illuminate. In addition, they do not produce sideways glare that may annoy neighbors and can hamper surveillance by police and private security. Figure 5 [image omitted; see the official code] Figure 5 [image omitted; see the official code] (2) All exterior lights and illuminated signs shall: a. Be designed, located, installed and directed in such a manner to prevent objectionable light at and across the property lines and to prevent glare at any location on or off the property; b. Be of a white light, such as metal halide, incandescent or a lamp with a color rendering index above seventy (70); c. Not exceed the maintained horizontal illuminance recommendations set by the Illuminating Engineering Society of North America (IES) or an average illumination level of one and five-tenths (1.5) foot-candles for the illuminated area; d. Not exceed one-tenth (0.1) foot-candle as a direct result of the on-site lighting measured twenty (20) feet beyond the property line of the development site; e. Be full cut-off style fixtures for all parking area lighting. (See Figure 5); f. Be illuminated with flush-mounted, flat lens light fixtures for all under-canopy fueling areas. (See Figure 5); g. Be shielded to prevent glare and/or light trespass from all building, site and aesthetic lighting; h. Uplighting is prohibited for externally illuminated signs except for monument signs of less than six (6) feet overall height; i. Be full cut-off or a shielded type fixture (wallpack style fixtures are not acceptable) for all building lighting for security or aesthetics. Floodlighting is discouraged; however, if used, it shall be shielded to prevent the following: 1. Glare for pedestrians or drivers; 2. Light trespass beyond the property line; and 3. Light above a ninety (90) degree horizontal plane; j. Be required to be turned off after business hours between midnight and 6:00 a.m., leaving only the necessary lighting for site and building security for all nonessential lighting. For purposes of this Subsection, nonessential lighting shall include display, aesthetic and sign lighting, and may include parking lot lighting. Outdoor display lots for vehicle sales and leasing shall also comply with the requirements of this Subsection by reducing the light levels between midnight and 6:00 a.m. to illumination levels sufficient for security purposes only; k. Not be installed, illuminated or maintained with a permanent beacon or searchlight; and l. Have the following maximum mounting height; 1. Twenty-four (24) feet when the fixture is located within seventy-five (75) feet of the site's boundary; or 2. Forty (40) feet when the fixture is located beyond seventy-five (75) feet from the site's boundary; and 3. Constructed without wood poles. (3) Exemptions: a. Except for Subparagraph (2)i. above, outdoor lighting for sports and athletic fields shall: 1. Be installed with internal louvers and external shields to minimize sky glow; 2. Not have floodlights aimed above sixty-two (62) degrees; 3. Have poles used for aerial sports such as baseball or softball at least seventy (70) feet in height to minimize sky glow and the effect upon surrounding uses; 4. Be shut off within one (1) hour after the game or event has ended. b. Seasonal decorations with individual lights displayed no longer than sixty (60) days per calendar year. c. Residential incandescent lighting of one hundred fifty (150) watts or fewer for each light fixture, and/or fluorescent lights of twenty (20) watts or fewer per fixture. d. Temporary lighting for fire, police, emergency or repair workers. e. Temporary lighting for construction activity or periodic events (such as fairs, fiestas, carnivals and similar temporary uses), if approved in advance by the Director of the Department of Land Use Administration after consulting with the Department of Transportation. f. Colored lights used as an accent to building facades and signage if the structure incorporating the accent lighting is neither located adjacent to, nor directed at, a residential use. g. Lighting adjacent to the Historic Arkansas Riverwalk of Pueblo (HARP), provided that the Administrative Official makes the following findings of fact: 1. Ambient light levels for outdoor gathering spaces and dining areas within and adjacent to the HARP are not greater than six (6) foot-candles; 2. Pedestrian walkways are provided with a maximum ambient light level of three (3) foot-candles; and 3. Appropriate on-site lighting has been provided despite anything to the contrary in Subparagraphs 17-4-52(2)c. and d. above. h. Uplighting intended to highlight building entrances, architectural features, flags, landscaping and works of art, provided that the Administrative Official makes the following findings of fact: 1. The illumination source is shielded so it is not visible from adjacent properties; 2. The illumination source is not a floodlight mounted on a freestanding pole; 3. All building facade illumination is located as close to the wall as possible and confined to light the building as an accent and not fully illuminate any building facade or project into the sky; and 4. Uplighting measurable at the ground level has been included in the maximum allowable light levels allowed for the site. (4) Lighting plan submission requirements for existing and proposed lighting: a. Plans indicating the location, type and height of the luminaries, including both building and ground mounted; b. A description of the luminaries, including lamps, poles or other supports, and shielding devices, which may be provided as catalogue cut sheets from the manufacturer; c. Photometric data, such as that furnished by the manufacturer, showing the angle of the light emissions; and d. Additional information as may be required by the Director of the Department of Land Use Administration in order to determinate compliance with this Section. (4.5) Regulations for nonconforming lights, light fixtures and light poles. All legal nonconforming lights, light fixtures and light poles shall immediately lose their legal nonconforming status and, thereafter, shall be brought into full compliance with the outdoor lighting performance standards or removed, when any one (1) of the following occur: a. The construction or erection of any building or structure upon any lot. b. The addition of five hundred (500) square feet or ten percent (10%) of the gross floor area to any building or structure, whichever is smaller. c. The legal nonconforming lights are accessory to a nonconforming use which has lost its nonconforming status. d. A land use application has been approved to change the use or dimension of the property. e. If a single light fixture or light pole is damaged more than fifty percent (50%), then only that fixture or pole must be brought into compliance or removed. f. If a nonconforming light fixture or pole is replaced, then only that fixture or pole must be brought into compliance. (5) Any person who installs or permits the installation of outdoor lights which do not comply with the performance standards set forth in this Section shall be guilty of a Class 2 municipal offense and punished as provided in Section 1-2-1.

(Ord. No. 7032 §1, 8-11-03; Ord. No. 7058 §1, 10-14-03; Ord. No. 7797 §1, 5-12-08; Ord. No. 7887 §§1, 2, 9-22-2008; Ord. No. 9239 §58, 2-26-18)

Ask a question about Pueblo law

Corpus searches the Pueblo sections it holds and shows the ones that match, with their citations. Free, no sign-in.