§ 4-6-2 — Amendments
Code of Ordinances of the City of Pueblo, Colorado (Codified through Ordinance No. 11209, adopted June 25, 2026 (Supp. No. 110)) · Pueblo Code of Ordinances § 4-6-2
Corpus is an independent public-information project, not the official City of Pueblo website. Stable reference: corpuslaw.us/code/f9735dd5-e0d5-4264-8307-c974aecf3b87
Sec. 4-6-2. - Amendments.
(a) Section R103 of the I.R.C., entitled "Department of Building Safety," is amended to read as follows: "R103 Southern Colorado Building Department - Enforcement Agency. "Administration and enforcement of this Code and all related and secondary codes are hereby delegated to the Southern Colorado Building Department. Wherever in this Code the phrase 'building official' appears, it shall be construed to refer to the Director or the Building Official of the Southern Colorado Building Department or the Building Official's designated representative. The building official, the building official's designated representatives, and such building inspectors as the building official may appoint, shall be vested with the authority of a law enforcement officer with respect to enforcing this Code and Chapter 6 of Title IV of the Pueblo Municipal Code, including the authority to issue summons and complaints for the violation thereof." (b) Section R103.1, entitled "Creation of enforcement agency," Section R103.2, entitled "Appointment," and Section R103.3, entitled "Deputies," are deleted. (c) Subsection R105.2 of the I.R.C., entitled "Work exempt from permit," number 7., is amended to read as follows: "7. Prefabricated swimming pools accessory to a Group R-3 occupancy, which are installed entirely above ground." (d) Section R105 of the I.R.C., entitled "Permits," is amended by the addition of Subsection R105.10, entitled "Issuance of permit," to read as follows: "R105.10 Issuance of permit. A building permit shall be issued only to the contractor performing the work covered by the contract between the owner and the contractor. Such permit shall be delivered only to the contractor or the contractor's authorized representative(s). Should any portion of the work be excluded from the contract, the application or permit shall state the portions so excluded. Should the contractor be discharged or abandon the work, the contractor shall immediately notify the building official in writing. No further work shall be performed until a successor contractor has been selected who shall notify the building official in writing of the contractor's selection to complete the work." (e) Subsection R106.1 of the I.R.C., entitled "Submittal documents," is amended to read as follows: "Construction documents will also include all plans and specifications, drawings, diagrams, calculations, computations, reports, specifications and other necessary data to complete the habitable structure, along with the necessary code study to compare and delineate the occupancy use and fire resistive type of construction within the I.R.C. Each set of plans and specifications shall bear the stamp or seal and signature of an engineer or architect licensed under Title 12 of Colorado Revised Statutes and in accordance with Sections 12-120-216 and 12-120-417, C.R.S., respectively." (f) Subsection R108.2 of the I.R.C., entitled "Schedule of permit fees," is amended by the addition of two (2) new subsections, R108.2.1 and R108.2.2, to read as follows: "R108.2.1 Permit fees. The fee for each permit shall be as established in the fee schedule adopted by the City Council by resolution. "R108.2.2 Plan review fees. Plan review fees shall be as established in the fee schedule adopted by the City Council by resolution." (g) Section R110.3.1 of the I.R.C., entitled "Certificate issued," is amended to add a new subsection R110.3.1 to read as follows: "R110.3.1 Public improvement requirements for a certificate of occupancy. Applications for building permits for buildings or structures for one- and two- family dwelling units and town homes shall be accompanied by a set of plans or a drawing which shows all existing and proposed public improvements required by the ordinances of the City. Foundation plans and soils report shall be prepared by and bear the seal of an architect or engineer licensed to practice in Colorado. Accessory structures shall have plot plans showing all existing and proposed public improvements required by ordinances of the city. Before any building permit is issued, all applications for building permits and accompanying plans or drawings shall be reviewed by the Director of Public Works to determine whether the proposed construction will require the installation or reconstruction of public improvements. For purposes of this Section, public improvements shall include, but not be limited to, street paving, curbs, gutters, sidewalks, drainage facilities and the dedication of land for such purposes. Upon request, the Director of Public Works shall provide a written statement of the public improvements that will be required as a condition for the issuance of a building permit and a certificate of occupancy. No certificate of occupancy shall be issued for any structure or building until all public improvements required by the ordinances of the City shall be constructed in full compliance with City engineering regulations, design standards and construction specifications as adopted by resolution of the City Council. Acceptance of required public improvements shall be completed upon written notification signed by the Director of Public Works. If it is determined by the Director of Public Works that any such public improvements are necessitated by the proposed construction, a condition shall be inserted in any building permit to be issued for such proposed construction, which shall require the dedication of such land and improvements to the City. The applicant for such building permits, if not the owner, shall notify the owner of the requirements to dedicate to the City such public improvements. The cost of any such improvements shall be borne by the owner, and the construction shall be subject to the provisions of all applicable City ordinances, resolutions, regulations and policies. Failure to comply with the provisions for public improvements required by this Section shall be deemed a violation of the Building Code and shall constitute grounds for applicable penalties as provided in Titles IV and XII of the Pueblo Municipal Code and for revocation of any issued certificate of occupancy or temporary certificate of occupancy." (h) Subsection R113.4 of the I.R.C., entitled "Violation penalties," is amended to read as follows: "R113.4 Violation penalties. Any person, firm or corporation violating any of the provisions of this Code, upon conviction thereof, shall be punished as provided in Section 4-6-6 of the Pueblo Municipal Code. The application of any such penalty shall not be held to prevent the enforced removal of prohibited conditions." (i) Subsection R301.2, entitled "Climatic and Geographic Design Criteria," is amended by the addition of Table R301.2(5), entitled "Pueblo County Ground Snow Loads," to read as follows: "Table R301.2(5) Pueblo County Snow Loads Elevation (asl) | Ground Snow Load (PSF) 5,300 | 20 5,550 | 23 5,800 | 25 6,050 | 27 6,300 | 30 6,550 | 33 6,800 | 35 7,050 | 38 7,300 | 40 7,550 | 41 7,800 | 43 8,050 | 44 8,300 | 45 8,550 | 46 8,800 | 48 9,050 | 49 9,300 | 50 9,550 | 51 9,800 | 52 10,050 | 54 10,300 | 55 10,550 | 56 10,800 | 58 11,050 | 59 11,300 | 60" (j) Subsection R302.5.1, Opening protection, of the I.R.C., is amended by deleting the words "equipped with a self-closing or automatic closing device" at the end of the second sentence. (k) Subsection R309.1 of the I.R.C., entitled "Floor surface", is amended by adding Exception 1 to read as follows: Exception 1. The floor surface shall not be required to slope when the foundation is for enclosed non-habitable accessory structure. (l) Subsection R311.3.2 of the I.R.C., entitled "Floor elevation at other exterior doors", Exception is amended to read as follows: Exception: When more than two (2) rises are required, landing length at the exterior door may be reduced to eighteen inches (18") provided the door does not swing over stairs. Maximum height of landing shall not exceed thirty inches (30") above adjacent grade. (m) Subsection R313.1 of the I.R.C., entitled "Townhouse automatic fire sprinkler systems," Exception is amended to read as follows: Exception #1. An automatic sprinkler system shall not be required where additions or alterations are made to existing townhouses that do not have an automatic sprinkler system installed. Exception #2. An automatic sprinkler system shall not be required with four or less attached dwelling units when separated in accordance with Section R302.2.2 item 2. (n) Subsection R313.2 of the I.R.C., entitled "One- and two-family dwellings automatic fire systems," is deleted. (o) Reserved. (p) Reserved. (q) Reserved. (r) Subsection M1305.1.3 of the I.R.C., entitled, "Appliances under floors," is amended by the addition of a sentence after the Exceptions which reads as follows: "All access openings to underfloor furnaces shall be provided with a permanent ladder for equipment access." (s) Subsection M1401.3 of the I.R.C., entitled, "Equipment and appliance sizing," is amended by adding a third exception which reads as follows: "3. Additions that are 600 square feet or less."
(Ord. No. 7141 §1, 5-10-04; Ord. 7937 §9, 12-8-08; Ord. No. 8156 §1, 3-22-10; Ord. No. 8223 §1, 6-28-10; Ord. No. 8342 §1, 4-25-11; Ord. No. 8893 §2, 7-13-15; Ord. No. 10468 §2, eff. 6-29-23; Ord. No. 11082 §3, 11-24-25; Ord. No. 11199 §6, 6-24-26; Ord. No. 11200 §1, 6-24-26)
Ask a question about Pueblo law
Corpus searches the Pueblo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
