Sec. 10-63. - Drawings and specifications.
(a) Required. Drawings and specifications shall be required prior to the issuance of a building permit under this division. Such drawings and specifications shall be checked and approved by the building department prior to the issuance of a building permit for the work to be performed. All drawings shall have the stamp of approval on each page thereof. (b) Responsibility for design. (1) A building permit shall not be issued unless the plans and specifications for such proposed construction, reconstruction, alteration, or remodeling conform to all applicable provisions and the regulations and restrictions of this Building Code. Plans and specifications shall be prepared and shall bear the seal and signature of a design professional practicing within their area of expertise and licensed by the State of Colorado. (2) Exception. Plans need not be prepared by a licensed design professional for the following: a. One-, two-, three-, and four-family dwellings, including accessory buildings commonly associated with such dwellings. b. Garages, industrial buildings, offices, farm buildings and buildings for the marketing, storage, or processing of farm products, and warehouses that do not exceed one story in height, exclusive of a one-story basement, and that are not designed for occupancy by more than ten persons. c. Additions, alterations, or repairs to the buildings listed in subsections 10-63(b)(1)(a) and (b) which do not cause the completed buildings to exceed the applicable limitations set forth in this subsection. d. Nonstructural alterations of any nature to any building if such alterations do not affect the life safety of the occupants of the building. (3) The building official may require plans, computations and specifications to be prepared, sealed and signed by a licensed design professional practicing within their area of expertise whenever, in the opinion of the building official, the project is of such complexity as to require the preparation of such by a licensed design professional. Building permits for remodeling buildings or structures shall not be issued without requiring complete plans. (4) When it is required that documents be prepared by a licensed design professional, the building official shall be authorized to require the owner to engage and designate on the building permit application a registered design professional who shall act as the registered design professional in responsible charge. If the circumstances require, the owner shall designate a substitute registered design professional in responsible charge who shall perform the duties required of the original registered design professional in responsible charge. The building official shall be notified in writing by the owner if the registered design professional in responsible charge is changed or is unable to continue to perform the duties. The registered design professional in responsible charge shall be responsible for reviewing and coordinating submittal documents prepared by others, including phased and deferred submittal items, for compatibility with the design of the building. (c) Information and preparation. Drawings, when required, shall be made to scale upon substantial paper, plastic or cloth, and the drawings and specifications shall be complete and of sufficient clarity to indicate the entire nature and extent of the work proposed and to indicate in detail that the building, structure and utilities will conform to the provisions of this Building Code and all relevant laws, rules and regulations. Plans may be submitted electronically upon approval of the building official. (1) Mechanical drawings, specifications and analyses shall contain the following: a. The name, signature and address of the person responsible for the preparation of such drawings and specifications, the seal of the design professional responsible for the preparation of such drawings and specifications on each drawing and the signature of the design professional affixed to each page thereof. b. At least single-line drawings, including typical isometric, of plumbing, heating and air-treatment systems. c. A Btu rating of gas units, including the method of combustion, air supply, the type of refrigeration and horsepower and the gas meter locations. d. Heating, ventilation, cooling and fire protection details and calculations. (2) Electrical drawings, specifications and analyses shall contain the following: a. The name, signature and address of the person responsible for the preparation of such drawings and specifications and the seal of the design professional responsible for the preparation of such drawings and specifications stamped on each drawing and the signature affixed thereto. b. A complete electrical layout with a service diagram showing load breakdown and sizes of service and feeder panels. c. Calculations indicating the determination of sizes of all electrical wiring and equipment. d. The complete elevator layout. (3) Additional information that may be required by the building department shall include the following: a. Reports of an independent testing agency which substantiate the requirements of this Building Code regarding structural or fire-resistive characteristics of the building or portion thereof. b. Calculation indicating the determination of sizes of elements of the structure. c. Any other information that may be deemed necessary in the determination of compliance with the requirements of this Building Code. d. A survey establishing the location of boundaries and the drainage of the property upon which the operations are to be executed shall be furnished. e. The construction documents shall show in sufficient detail the location, construction, size and character of all portions of the means of egress in compliance with the provisions of the Building Code. In other than one-and two-family dwellings and townhomes the construction documents shall designate the number of occupants to be accommodated on every floor, and in all rooms and spaces. f. Construction documents for all buildings shall describe the exterior wall envelope in sufficient detail to determine compliance with the Building Code. The construction documents shall provide details of the exterior wall envelope as required, including flashing, intersections with dissimilar materials, corners, end details, control joints, intersections at roof, eaves or parapets, means of drainage, water-resistive membrane and details around openings. g. The construction documents shall include manufacturer's installation instructions that provide supporting documentation that the proposed penetration and opening details described in the construction documents maintain the weather resistance of the exterior wall envelope and shall fully describe the exterior wall system which was tested, where applicable, as well as the test procedure used. h. The construction documents submitted with the application for building permit shall be accompanied by a site plan showing to scale the size and location of new construction and existing structures on the site, distances from lot lines, the established street grades and the proposed finished grades and, as applicable, flood hazard areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size of existing structures and construction that are to remain on the site or plot. The building official is authorized to waive or modify the requirement for a site plan when the application for building permit is for alteration or repair or when otherwise warranted. i. Where design flood elevations are not specified, the elevation shall be established in accordance with IBC Section 1612.3.1. j. Demolition permits require the submittal of a State of Colorado permit for the demolition project. (4) For the purposes of this section, deferred submittals are defined as those portions of the design that are not submitted at the time of the application and that are to be submitted to the building official within a specified period. Deferral of any submittal items shall have the prior approval of the building official. The registered design professional in responsible charge shall list the deferred submittals on the construction documents for review by the building official. Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the deferred submittal documents have been approved by the building official. (5) Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in compliance with the approved construction documents shall be resubmitted for approval as an amended set of construction documents. (d) Disposal of drawings. After final inspection has been made, upon the completion of the work approved in a set of drawings and specifications, the building department copy of such drawings and specifications shall be disposed of in the following manner: (1) All drawings and specifications pertaining to city-owned buildings, structures or utilities shall be kept in a permanent file. (2) Other drawings and specifications may be disposed of at any time after two years have elapsed from the date of the issuance of the building permit. (3) Drawings and specifications submitted for checking only may be disposed of after 90 days. (e) Expiration of plan review. Applications for plan review shall expire if no building permit is issued within 180 days following the date the application was accepted. Any plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the building official. (1) The building official may extend the time to obtain a building permit for a period not exceeding 180 days on written request of the applicant prior to the expiration date showing that circumstances beyond the control of the applicant have prevented the issuance of the permit. (2) In order to resubmit an application after expiration, the applicant shall pay a new plan review fee in an amount established by the schedule of fees adopted by resolution as required for a new plan review, provided no changes have been made or will be made in the original plans and specifications for such work and that the plans are still in compliance with this Building Code, if a later edition of the Building Code has been adopted by the city council, provided further that the expiration has not exceeded 180 days. (3) In order to resubmit an application after expiration, the applicant shall resubmit plans and pay a new plan review fee as set forth in the schedule of fees established from time to time by resolution.
(Code 1975, § 44-28; Ord. No. 1530, 2-10-86; Ord. No. 2033, § 1(d), 12-17-90; Ord. No. 2203, § 11, 10-12-92; Ord. No. 2384, § 12, 11-27-95; Ord. No. 3136, § 1, 7-13-10; Ord. No. 3252, § 4, 7-23-13)
Ask a question about Thornton law
Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.