Sec. 74-158. - Degree of hazard.
The type of protective device required under Section 74-157(a) shall depend upon the degree of hazard which exists as follows in the case of any premises where: (1) There is an auxiliary water supply as stated in Section 74-157(a)(1) and it is not subject to any of the following rules, the city water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow prevention device. (2) There is water or substance that would be objectionable but not hazardous to health, if introduced into the city water system, the city water system shall be protected by an approved double check-valve assembly. (3) There is any material dangerous to health which is handled in such a fashion as to create an actual or potential hazard to the city water system, the city water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow prevention device. Examples of premises where these conditions will exist include sewage treatment plants, sewage pumping stations, chemical manufacturing plants, hospitals, mortuaries and plating plants. (4) There are uncontrolled cross connections, either actual or potential, the city water system shall be protected by an approved air gap separation or an approved reduced pressure principle backflow prevention device at the service connection. (5) Because of security requirements or other prohibitions or restrictions it is impossible or impractical to make a complete in-plant cross connection survey, the city water system shall be protected against backflow or backsiphonage from the premises by the installation of a backflow prevention device in the service line. In this case, maximum protection will be required; that is, an approved air gap separation or an approved reduced pressure principle backflow prevention device shall be installed in each service to the premises. (6) Reserved.
(Code 1975, § 40-24.2; Ord. No. 1278, 9-12-83; Ord. No. 3757, § 3, 10-28-25)
Ask a question about Thornton law
Corpus searches the Thornton sections it holds and shows the ones that match, with their citations. Free, no sign-in.