Sec. 12-78. - Lighting standards.

(a) Every habitable room shall have at least one (1) window or skylight facing directly to the outdoors, provided that, if connected to a room or area used seasonally (e.g. porch), then adequate daylight must be possible through this interconnection; have a minimum total window area, measured between stops, at least twelve and one-half (12.5) per cent of the floor area of such room; whenever walls or other portions of structures face a window of any such room and such light-obstruction structures are located less than three (3) feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area; and whenever the only window in a room is a skylight-type window in the top of such room, the total window area of such skylight shall equal at least fifteen (15) per cent of the total floor area of such room. (b) Every bathroom and water closet compartment and nonhabitable room used for food preparation shall comply with the light standards for habitable rooms contained in this code, except that no window or skylight shall be required in such rooms if they are equipped with a ventilation system in working condition which is approved by the director of health. (c) Every public hall and stairway in every multiple dwelling shall be adequately lighted by natural or artificial light at all times, so as to provide in all parts thereof at least ten (10) footcandles of light at the tread of floor level. Every public hall and stairway in structures containing not more than two (2) dwelling units may be supplied with conveniently located light switches controlling an adequate lighting system which may be turned on when needed instead of full-time lighting.

(Ord. of 9-14-05, § 12-35)

Ask a question about Bristol law

Corpus searches the Bristol sections it holds and shows the ones that match, with their citations. Free, no sign-in.