For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-7 — Outside, above-ground bulk storage of combustible liquid regulated

Code of Ordinances of the City of Bristol, Connecticut (Codified through Amendments of February 11, 2025, effective February 28, 2025. (Supp. No. 4)) · Bristol Code of Ordinances § 7-7

Corpus is an independent public-information project, not the official City of Bristol website. Stable reference: corpuslaw.us/code/24c0f363-eb99-4e92-a659-93e1e8208b6a

Sec. 7-7. - Outside, above-ground bulk storage of combustible liquid regulated.

(a) The term "combustible liquid" whenever used in this section shall mean the term as defined in the National Fire Protection Association's definition Number 30 entitled, "Flammable and Combustible Liquids Code" as recognized and enforced by the Connecticut Commissioner of Public Safety and State Fire Marshal pursuant to Section 29-320 C.G.S. and Sections 29-320-2a and 29-320-3a of the Regulations of Connecticut State Agencies, as of the effective date of this section and as amended from time to time. Bulk storage shall mean any tank that has a capacity that exceeds ten (10) gallons. (b) The outside, above-ground bulk storage of combustible liquid is prohibited within the city unless the container meets the requirements of subsection (c), (d), (e) or (f) of this section. (c) The outside, above-ground bulk storage of combustible liquid is permitted in Fire District No. 1, Fire District No. 2 and the outer fire limits for residential, commercial, industrial and municipal heating under the following circumstances and provided said storage meets all the following criteria: (1) Each storage tank shall not exceed three hundred thirty (330) gallons of capacity. (2) Each storage tank shall be connected to a fuel burning heating appliance and used in connection therewith. (3) For one- and two-family residences, only one (1) storage tank shall be permitted per family, and for mobile homes, only one (1) storage tank shall be permitted. For three (3) or greater family residences, no more than two (2) storage tanks shall be permitted. (4) For non-residential property, one (1) storage tank shall be permitted for each separate and clearly discernible business, industrial, commercial, or municipal establishment or department. (5) Each storage tank shall be supported on a poured concrete stabilization pad at least four (4) inches thick, whose inside dimensions shall be no less than the exterior dimensions of the storage tank. (6) Each storage tank shall be approved by the city fire marshal and building official to ensure compliance with all federal, state and city regulations. An applicant seeking approval for a storage tank for residential, commercial, industrial or municipal heating shall provide the building official with three (3) copies of a scaled drawing of the proposed tank's location that indicates the capacity of the tank, its dimensions, the dimensions of the poured concrete stabilization pad, and the relationship of the proposed tank and pad to all existing or proposed structures on the property. Concrete bollards or other protective measures, such as landscaping or plant barriers may be required to prevent damage or deter vandalism to the proposed storage tank. (d) The outside, above-ground bulk storage of combustible liquid is permitted for storage of fuel for the purpose of providing emergency electric power shall be permitted as provided for in section 7-16 of this Code. (e) The outside, above-ground bulk storage of combustible liquid is permitted for storage of fuel as a depot for distribution to end users in the normal course of commerce by fuel distributors under the following circumstances: (1) Storage tanks in existence prior to the effective date of this section that meet all federal, state and city laws and regulations on that date are deemed approved under this section provided they comply with all federal and state laws and regulations as they are adopted and amended from time to time. (2) A storage tank constructed on or after the effective date of this section shall be permitted only in the outer fire limits and approved by the city fire marshal and city building official to ensure compliance with all federal, state and city regulations. An applicant seeking approval for a storage tank on or after the effective date of this section further shall provide the building official with proof of zoning compliance and three (3) copies of the site plan approved by the City of Bristol land use authorities whose jurisdictions are implicated in said application (e.g., planning commission, zoning commission, inland wetlands agency, zoning board of appeals, etc.). (f) The outside, above-ground bulk storage of combustible liquid is permitted in Fire District No. 1, Fire District No. 2 and the outer fire limits for combustible fuel for the limited purposes of fueling or refueling construction or maintenance equipment or vehicles stored or garaged on-premises. The applicant first must obtain from the city a certificate of zoning compliance for the use or proposed use of the premises on which the fueling or refueling of construction or maintenance equipment or vehicles is to occur. A permit for the outside, above-ground bulk storage of combustible fuel shall issue from the city building official and city fire marshal jointly upon the applicant's submission of a site plan and inspection by the aforementioned city officials verifying compliance with the following: (1) No individual storage tank's capacity exceeds one thousand (1,000) gallons and the site capacity does not exceed two thousand (2,000) gallons. (2) The storage tank(s) meet(s) the UL 2085 Standard for Insulated Aboveground Tanks for Flammable and Combustible Liquids. (3) Each storage tank is supported by a poured concrete stabilization pad at least four (4) inches thick, with the pad's inside dimensions no less than the exterior dimensions of the tank. (4) Any weather protection provided for the storage tank is made totally of noncombustible materials. (5) No storage tank is closer than twenty-five (25) feet from any building regardless of whether said building is inhabited. (6) A copy of the storage tank(s) manufacturer's recommendations or instructions for installation have been provided to the city fire marshal, and said recommendations or instructions have been followed unless, by following said recommendations or instructions, the installation would not be in compliance with this ordinance or other laws. (7) Provisions are provided for the physical protection of the storage tank(s) so as to prevent its (their) exposure to accidental collision or any other reasonably foreseeable hazards arising generally or specifically from the use of the premises. (8) Provisions are provided for securing the storage tank(s) from unauthorized use or discharge. (9) Provisions are provided for locating the storage tank(s) on the premises, and for screening the storage tank(s), so as to minimize the impact of undesirable noise, fumes, and any other activity associated with its (their) use that reasonably can be foreseen to disturb the peaceful enjoyment of neighboring property or disrupt passers-by. The city building official and city fire marshal are authorized, jointly and individually, to order additional screening, vapor recovery systems or other requirements to mitigate any hazard or undesirable effect that interferes with the peaceful enjoyment of neighboring property or disrupts passers-by upon a complaint received for a period one (1) year from the date on which the use of the storage tank(s) is (are) authorized. Said officials, jointly or individually, shall provide the owner with at least thirty (30) days to comply with said additional requirements, which shall append to the permit. Failure to comply with these additional requirements shall render the permit null and void. These provisions shall not limit in any way the authority of the city building official, fire marshal or any other city official to enforce any other applicable law or ordinance.

(Ord. of 10-26-61; Ord. of 1-11-00; Ord. of 12-9-03; Ord. of 3-13-07)

Ask a question about Bristol law

Corpus searches the Bristol sections it holds and shows the ones that match, with their citations. Free, no sign-in.