§ 12-172 — Underground or outdoor petroleum or hazardous material storage in Class I watershed areas
Code of Ordinances of the City of Danbury, Connecticut (Codified through Ordinances of May 2, 2023 (Supp. No. 2; publisher-stale)) · Danbury Code of Ordinances § 12-172
Corpus is an independent public-information project, not the official City of Danbury website. Stable reference: corpuslaw.us/code/5d8a1baf-e1a7-4089-9ab6-42f656a2d41b
Sec. 12-172. - Underground or outdoor petroleum or hazardous material storage in Class I watershed areas.
(a) New installations of underground storage tanks. The construction or installation of underground storage tanks shall only be permitted within a Class I watershed area if approved by the Director of Health and the Building Official. Such approval shall only be granted if the following conditions are met: (1) The underground storage tank must be protected by a secondary containment structure consisting of a vault or a double-lined fiberglass tank or equivalent, as specified in 40 CFR 265.193. (2) The tank system must be installed with a leak-detection system as specified in 40 CFR 265.193. (3) The underground storage tank must be installed with a structural mechanism for spill and overfill protection as specified in 40 CFR 265.194. (4) The owner of the tank system must adhere to all notification and tank monitoring procedures specified in 40 CFR 265.196. (b) New installations of aboveground tank systems. Outdoor aboveground tank systems may only be constructed or installed if they include a secondary containment area and a roof and sump. The design and construction of such secondary containment systems shall be subject to the review and approval of the Director of Health and the Building Official, or their respective designees. (c) Requiring replacement installations. The Director of Health shall be authorized to issue an order directed to the owner of any underground storage tank which is found to be leaking or discharging its contents requiring such owner to empty the tank and thereafter replace it with an aboveground tank system within the period of time provided in such order. The Director of Health shall be authorized to issue an order directed to the owner of any aboveground tank system which is found to be leaking or discharging its contents requiring such owner to empty the tank and thereafter repair or replace the tank system within the period of time provided for in such order. Aboveground replacement tank systems shall be isolated from the external environment by a roofed secondary containment system. The period of time fixed for the repair or replacement of any such tank system shall be established by the Director of Health after an evaluation of the time necessary to complete the work as well as of any potential risks associated with the delay. The design and construction or installation of replacement of any such tank system and secondary containment system shall be subject to the review and approval of the Director of Health and the Building Official, or their respective designees.
(Code 1961, § 9-82; Ord. No. 475, 9-8-1993)
Ask a question about Danbury law
Corpus searches the Danbury sections it holds and shows the ones that match, with their citations. Free, no sign-in.
