For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 42-34 — Drainage specifications

Code of Ordinances of the City of Danbury, Connecticut (Codified through Ordinances of May 2, 2023 (Supp. No. 2; publisher-stale)) · Danbury Code of Ordinances § 42-34

Corpus is an independent public-information project, not the official City of Danbury website. Stable reference: corpuslaw.us/code/1a245361-1807-44ca-9949-ffd339c4f25a

Sec. 42-34. - Drainage specifications.

(a) Storm drainage. The storm drainage system shall be reviewed by the City Engineer and the engineering plan shall reflect the drainage layout as approved. The minimum grade of any drainage pipe shall be one (1) percent unless otherwise directed. (b) Excavation laying and backfilling. (1) The widths of the trench in which the pipe is placed shall be sufficient to permit thorough tamping of the backfill under and around the pipe. Where rock and earth boulders are encountered, they shall be removed below grade and replaced with suitable materials in such a manner as to provide an earth cushion having a thickness under the pipe of not less than eight (8) inches. In no case shall the top of any drainage pipe be less than eighteen (18) inches below the finished grade of the pavement. Where soft, spongy or other unstable soil is encountered at the grade established, such unstable soil under the pipe and for a width of one (1) foot on each side of the pipe, shall be removed and replaced with gravel or other suitable material. In all cases, the bedding shall be thoroughly compacted and shall provide a firm foundation for the pipe. (2) Pipes shall be laid to true line and grade on prepared bed of the trench. All connections for making field joints with corrugated metal pipe shall be made as recommended by the manufacturer using corrugated metal bands securely fastened. All joints in making field connections of reinforced concrete pipe shall be filled with a Portland cement mortar. (3) Backfilling of all drains shall be done in accordance with section 42-33(c) on fills under the heading of excavation, filling and rough grading. Any additional drainage facilities not shown on the approved plan but are reasonably necessary to conform to acceptable engineering standards for roadway construction shall be constructed by the subdivider at the subdivider's expense when requested by the City Engineer. (c) Pipe. Storm drain and culvert pipe may be of either corrugated metal or reinforced concrete as directed by the City Engineer. The minimum pipe size shall be fifteen (15) inch. Lesser diameter pipe may be permitted under certain conditions but only with express consent of the City Engineer. In all cases, the conduit shall conform to the specifications of the Connecticut Department of Transportation. (d) Catchbasin and curb inlets. The following specification indicates the minimum acceptable construction for typical catchbasins and curb inlets. In general, the catchbasin tops shall be of the precast variety but when Granite or concrete curbing is required, the cast iron frame and grade standard catchbasin of the City of Danbury shall be required. (1) Location. Catch basins shall be constructed at all points of change of slope or alignment and at all junction points. At no time shall catchbasins be placed further apart than three hundred fifty (350) feet on slopes less than three percent (3); three hundred twenty-five (325) feet on slopes from three (3) to six (6) percent; and three hundred (300) feet on slopes over six (6) percent in steepness. (2) Excavation. The hole for a catchbasin shall be excavated to a depth of thirty-six (36) inches below the designated elevation of the invert of the effluent pipe. In the event of a wet condition, crushed stone to a minimum depth of nine (9) inches leveled and compacted over the entire area of the excavation shall be laid in the hole. The foundation shall consist of an eight (8) inch thick slab of concrete. The slab shall extend six (6) inches beyond the outside of the walls of the catchbasin. In all cases, the slab shall be smooth and level. (3) Walls. The walls shall be constructed of solid concrete catchbasin blocks. They shall measure six (6) inches by eight (8) inches by twelve (12) inches. To a maximum depth of six (6) feet below the finished surface, the catchbasin walls shall be constructed of concrete blocks. From five (5) feet to a maximum depth of ten (10) feet below the finished surface, the walls shall be constructed solid concrete catchbasin blocks having a width of eight (8) inches in thickness. Below ten (10) feet from the finished surface the catchbasin walls shall be twelve (12) inches in thickness and shall be constructed of solid concrete blocks or poured concrete. The inside dimensions of the catchbasin shall remain constant from top to bottom and shall match the frame opening of the curb inlet to be used. All blocks shall be laid in a workmanlike manner and the inside joints shall be pointed up (in an approved manner). Precast concrete units will be permitted. (4) Installation of pipe. Concrete blocks around all pipes entering or leaving the catchbasin shall be cut to fit the contour of pipe as closely as possible; common brick may be used for this purpose. The ends of all pipes shall be cut off flush with the inside surfaces of the catchbasin walls. All rough edges shall be smooth and reinforcing wire shall be cut flush with the surface. All joints adjacent to a pipe opening shall be solidly filled with mortar for the full thickness of the wall. (5) Curb inlets. All catchbasins shall be capped using precast basin tops and shall be so installed that the flow line of the grade is two (2) inches below the finished gutter grade and the pavement shall be sloped towards the inlet. (6) Steps. Catch basins having a greater depth than forty-eight (48) inches from the finished surface to the top of the concrete base shall be provided with steps. Steps shall be of wrought iron having a minimum diameter of three-quarters (¾) inch; shall be hot-bended to shape and shall be galvanized after bending. They shall be solidly set in the masonry at the time of construction and shall extend all the way through the wall. Reinforced bars shall not be permitted as steps. (e) Open ditches. With the approval of the Commission, open ditches may be used when the grade of the land traversed is relatively flat, or when it is desirable to drain and dry surrounding areas. In no case shall the grade of an open ditch exceed three (3) percent. (f) Rip-rap. Rip-rap shall consist of field stones placed in such a manner as to perfect a relatively smooth line and grade. The rip-rap shall be placed for a distance of twenty (20) feet at the influent and effluent ends of all drainage lines to prevent scour and erosion. Paved sections as approved by the City Engineer may be used in lieu of stone riprap. (g) Discharge area. Where drainage pipes are to discharge onto proposed building sites, the pipe shall be carried to the limit of the graded area behind a house, or a minimum distance of one hundred (100) feet from the edge of the right-of-way. (h) Easements. Permanent easements of a nature acceptable to the Corporation Counsel shall be provided in all cases where drainage pipes or ditches cross lands other than street right-of-way. A minimum width of fifteen (15) feet shall be required and said easements shall be clearly defined on the linen drawing on file in the land records. (i) Right to drain required. Where drainage waters are discharged directly or indirectly onto adjacent landowners, the subdivider shall secure written permission of a nature acceptable to the Corporation Counsel of said landowner to so do. (j) House and foundation drains. House and foundation drains in no case shall be permitted to discharge onto the highway. These drains may be connected to the stormwater system. All such drainage connections shall be made prior to construction of the final wearing course.

(Code 1961, § 17-26; Ord. No. 52, § 6, 12-7-1965)

Ask a question about Danbury law

Corpus searches the Danbury sections it holds and shows the ones that match, with their citations. Free, no sign-in.