For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17-52 — Approved sterilization and disinfection procedures

Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Code of Ordinances § 17-52

Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/971a5e89-da97-4fc7-9aaa-d63effa325d5

Sec. 17-52. - Approved sterilization and disinfection procedures.

All reusable or nondisposable items used to provide body arts services shall be thoroughly cleaned prior to sterilization using one (1) of the following methods: (1) The instruments shall be placed in an approved ultrasonic machine filled with an approved ultrasonic solution and cleansed of all foreign materials according to the manufacturer's directions. (2) Instruments unable to be cleaned ultrasonically are to be placed in an EPA-approved hospital disinfectant solution for a minimum of twenty (20) minutes. Following cleaning, instruments are to be dried and then placed into individual autoclave sterilization bags, then sealed and marked with the date of sterilization and a tape marker to indicate that the packet has been exposed to autoclaving. Sterilization shall be accomplished in an approved autoclave by exposure to steam for a minimum of fifteen (15) minutes at fifteen (15) pounds per square inch at a temperature of two hundred fifty (250) degrees Fahrenheit or one hundred twenty-one (121) degrees Celsius. Chemical sterilization (Chemiclave TM ) under pressure is also an acceptable method of sterilization, and the process recommended by the manufacturer must be followed meticulously to ensure adequate sterilization. If the indicator tape indicates that the packets have been exposed to sterilizing conditions, the instrument packets shall be stored in a clean, covered container to minimize contamination until used. The sterilizer shall be monitored monthly for effectiveness by the use of a spore test (Bacillus stearothermophilus) provided by an independent testing service. Records of testing reports shall be maintained in a log for two (2) years. Sterilizers shall be maintained in adequate working condition at all times. A sterilizer which does not provide adequate levels of time, temperature, and pressure so as to achieve sterilization shall be repaired or replaced immediately. A log of repair procedures shall be maintained for two (2) years. All surfaces which are directly in contact with the client or with the instruments used to provide a body arts procedure, as well as the surfaces immediately adjacent to the work area, including lights, chairs, tables, telephones, and walls, shall be cleansed immediately following a procedure using an approved disinfectant solution in a spray-wipe-spray method; the surfaces are sprayed, wiped with a clean, disposable cloth, then sprayed again and allowed to air dry. Disposables and single-use items shall be disposed into an approved container immediately following completion of the procedure. Under no circumstances is a single-use item to be re-used. Sharps containers must be located in close proximity to each work area. One (1) container may be used for multiple operators, but a minimum of one (1) sharps container for each separate room shall be provided. Failure to meet all provisions of this section shall be considered a critical violation of these regulations and an imminent health hazard shall be declared by the department, and such a violation shall be grounds for immediate suspension or revocation of the operating permit and/or the artist's license.

(Ord. No. 4-00, 2-14-00)

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.