4.10.2 - CIVIC BUILDING TYPE REGULATIONS

SEE NOTE 1 ***Expand table to lock table headings in place while scrolling*** DT Districts | MS Districts | CX Districts | MX-2 District | MX-1, NX & N Districts A. Building Siting. Refer to Figure 4.10-B Civic Building: Building Siting Examples and 4.18.1 Building Siting for explanation. 1 | Multiple Principal Buildings | not permitted | not permitted | permitted | permitted with 5.1 Campus Overlay | not permitted 2 | Minimum Front Lot Line Coverage | not required 3 | Occupation of Corner | not required 4 | Minimum Front Setback | behind the Building Line a minimum of 5' 5 | Minimum Corner Setback | behind the Building Line a minimum of 5 6 | Minimum Side Setback | 5' | 10' | 5' | 15' | 5'; 100' from residential uses 7 | Minimum Rear Setback | 0' | 5' | 5' | 15' | 25'; 100' from residential uses 8 | Minimum Lot Width Maximum Building Width | None none | 60' 140' | None none | 100' none | 120' 80' 9 | Maximum Building Coverage Maximum Impervious Area Additional Semi-Pervious Area | no limitation | 60% 75% 10% | 80% 80% 15% | 60% 80% 10% | 30% 50% 20% 10 | Permitted Parking & Loading Locations | shall not front primary streets | rear & limited side yards NOTE 2 | rear & side yards | rear & side yards | rear yard & limited side yards NOTE 2 11 | Permitted Vehicular Access | one driveway per street frontage; in MX-1 and N districts, locate only on side streets. Figure 4.10-B Civic Building: Building Siting Examples [image omitted; see the official code] Figure 4.10-C Civic Building: Height & Use Requirements [image omitted; see the official code] ***Expand table to lock table headings in place while scrolling*** DT Districts | MS Districts | CX Districts | MX-2 District | MX-1, NX & N Districts B. Height. Refer to Figure 4.10-C Civic Building: Height & Use Requirements and 4.18.2 Height for explanation. 12 | Minimum Overall Height | 1 story | 1 story | 1 story | 1 story | 1 story 13 | Maximum Overall Height | 8 stories | 3 stories | 4 stories | 6 stories | 2 stories 14 | Ground Story: (Measured floor-to-floor) Minimum Height Maximum Height | 10' 30' NOTE 3 | 10' 24' NOTE 3 | 10' 30' NOTE 3 | 10' 30' NOTE 3 | 10' 24' NOTE 3 15 | Upper Stories: (Measured floor-to-floor) Minimum Height Maximum Height | 9' 14' | 9' 14' | 9' 14' | 9' 14' | 9' 14' C. Uses. Refer to Figure 4.10-C Civic Building: Height & Use Requirements and 4.18.3 Uses for explanation. Refer to 3.0 for permitted uses. 16 | All Stories | only civic and institutional uses permitted by district NOTE 1 17 | Parking within Building | permitted fully in any basement and in rear of upper floors | not permitted 18 | Entrance to Parking/Loading within Building | any non-primary street facing facade | rear or side facade | not applicable 19 | Required Occupied Space | minimum 30' deep on all full floors from the front facade D. Street Facade Requirements. Refer to Figure 4.10-D Civic Building: Street Facade Requirements and 4.18.4 Street Facade Requirements for explanation. 20 | Minimum Transparency per each Story | 10% 21 | Blank Wall Limitations | required on ground story (refer to 4.18.4 B. for requirements) 22 | Front Facade Entrance Type refer to 4.19.1 Entrance Types | stoop, arcade 23 | Principal Entrance Location | front, corner side, or side facade 24 | Required Number of Street Entrances | no requirement 25 | Ground Story Vertical Facade Divisions | no requirement 26 | Horizontal Facade Divisions | no requirement 27 | Permitted Roof Types refer to 4.19.2 Roof Types | parapet, pitched, flat; tower; other roof types permitted with special permit (refer to 4.19.2 A.(4) Other Roof Types) Figure 4.10-D Civic Building: Street Facade Requirements [image omitted; see the official code] E. Notes. The following notes are keyed to the requirements in the building type table, A through D: 1. The Civic Building Type shall only be utilized for certain uses per the Building Type table, except that Civic Building Type buildings over 50 years old may be used for residential and lodging uses, retail uses, service uses, or employment uses. Further, in some districts, the Civic Building may only be used on a corner lot (refer to Figure 4.1-B Permitted Building Types by District for Residential Districts). 2. Lots wider than 140 feet are permitted to have one double-loaded aisle of parking (maximum width of 72 feet), located perpendicular to the front lot line. 3. If 18 feet or more in height, ground story shall count as 2 stories towards maximum building height.

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.