§ 4.11.2 — APARTMENT BUILDING TYPE REGULATIONS
Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.11.2
Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/b4ba1157-fff1-4d24-8482-399324f29bf7
4.11.2 - APARTMENT BUILDING TYPE REGULATIONS
***Expand table to lock table headings in place while scrolling*** MS-2 | MX-1 | MX-2 | NX-1 | NX-2 | NX-3 A. Building Siting. Refer to Figure 4.11-B Apartment Building: Building Siting and 4.18.1 Building Siting for explanation. 1 | Multiple Principal Buildings | not permitted | not permitted | permitted with 5.1 Campus Overlay | permitted with 5.1 Campus Overlay | not permitted 2 | Minimum Front Lot Line Coverage | 80% | 80% | 80% NOTE 1 | 70% 3 | Occupation of Corner | required | required | required | required 4 | Front Build-to Zone | within 2' of Building Line, minimum 10' deep front yard | within 2' of Building Line | within 5' of Building Line | within 2' of Building Line 5 | Corner Build-to Zone | within 5' of Building Line 6 | Minimum Side Setback | 7.5' | 7.5' | 10' | 5' | 5' | 7.5' 7 | Minimum Rear Setback | 5' | 5' | 20' | 5' | 5' | 5' 8 | Minimum Lot Width Maximum Building Width | 50' none | 50' 70' | 65' none | 50' 70' | 50' 70' | 50' 65' 9 | Maximum Building Coverage Maximum Impervious Area Additional Semi-Pervious Area | 45% 65% 25% | 45% 65% 25% NOTE 3 | 65% 80% 10% NOTE 3 | 35% NOTE 6 65% 15% NOTE 3 10 | Parking Lot & Detached Garage Location | rear yard | rear yard | rear yard; limited side yard NOTE 2 | rear yard 11 | Permitted Vehicular Access | one driveway per lot off corner side or interior side yard; shared driveways encouraged. B. Height. Refer to Figure 4.11-C Apartment Building: Height & Use Requirements. and 4.18.2 Height for explanation. 12 | Minimum Overall Height | 3 stories | 3 stories | 3 stories | 3 stories 13 | Maximum Overall Height | 5.5 stories | 5.5 stories | 6 stories | 4 stories 14 | All Stories: (Measured floor-to-floor) Minimum Height Maximum Height | 10' 14' | 10' 14' | 9' 14'; 20' on ground story NOTE 4 | 10' 14' Figure 4.11-B Apartment Building: Building Siting [image omitted; see the official code] Figure 4.11-C Apartment Building: Height & Use Requirements [image omitted; see the official code] ***Expand table to lock table headings in place while scrolling*** MS-2 | MX-1 | MX-2 | NX-1 | NX-2 | NX-3 C. Uses. Refer to Figure 4.11-C Apartment Building: Height & Use Requirements. and 4.18.3 Uses for explanation. Refer to 3.0 for permitted uses. 15 | Ground Story | residential & lodging uses permitted by district; maximum number of units per building defined by district NOTE 5 16 | Upper Stories | residential & lodging uses permitted by district; maximum number of units per building defined by district 17 | Parking within Building | permitted fully in any basement and in rear of upper floors 18 | Entrance to Parking in Building | rear facade | rear facade | rear or interior side facade | rear facade 19 | Required Occupied Space | minimum 30' deep on all full floors from the front facade D. Street Facade Requirements. Refer to Figure 4.11-D Apartment Building: Facade Requirements. and 4.18.4 Street Facade Requirements for explanation. 20 | Minimum Transparency per each Story | 15% NOTE 5 | 15% | 20% | 15% | 15% | 15% 21 | Blank Wall Limitations | required per floor on all stories of street facing facades (refer to 4.18.4 B. for requirements) 22 | Front Facade Entrance Type refer to 4.19.1 Entrance Types | stoop, porch 23 | Principal Entrance Location | front facade; no exterior stairs permitted on the front facade 24 | Required Number of Street Entrances | minimum one, maximum of 2 per building; no exterior stairs permitted on any street or side facade 25 | Ground Story Vertical Facade Divisions | none required | none required | every 90' of facade width | none required 26 | Horizontal Facade Divisions | required within 3' of the top of the ground story, and every fifth floor above the first floor 27 | Permitted Roof Types refer to 4.19.2 Roof Types | parapet, pitched, flat; tower | parapet, pitched, flat | parapet 28 | Special Materials Requirements (refer to 4.2.1 Materials for general materials requirements) | wood cladding and fiber cement board are not permitted as primary facade materials | brick only Figure 4.11-D Apartment Building: Facade Requirements [image omitted; see the official code] E. Notes. The following notes are keyed to the requirements in the building type table, A through D: 1. A landscaped court covering up to 35 percent of the front facade is permitted and may contribute to the Front Lot Line Coverage requirement, provided that a fence and landscaping fulfilling the requirements of 6.8 Frontage Buffer is provided along the building line. Refer to 4.2.5 Courtyards. Court facades shall fulfill 4.11.2 D. Street Facade Requirements. 2. Where noted, lots wider than 140' are permitted one double-loaded aisle of parking (maximum width of 65'), located perpendicular to street, which is exempt from Front Lot Line Coverage calculation. 3. Maximum impervious and semi-pervious area in any front yard (refer to 1.6) is 25 percent. 4. If 18 feet or more in height, ground story should count as 2 stories towards maximum building height. 5. In the MS-2 district, buildings located on street corners, may incorporate the following: a. Uses. Up to 25 percent of the ground story on the corner of the building may be used for permitted retail and service uses. b. Entrance Type. The storefront entrance type is required for retail or service uses, and may be used on up to 30 percent of any street facing facade. c. Ground Story Transparency. On the storefront entrance type, a minimum of 50 percent ground story transparency is required. 6. In the NX-1 district, on a lot located on a block that is adjacent to a block not containing any lot zoned to any N district, the maximum building coverage may be 45%. The preceding sentence is intended to allow for greater building coverage where the NX-1 lot is located in a neighborhood of higher density structures.
Ask a question about Hartford law
Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.
