For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.12.2 — STACKED FLATS BUILDING TYPE REGULATIONS

Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.12.2

Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/aa818ba3-8aa1-4bc7-bc9b-71337f0d408c

4.12.2 - STACKED FLATS BUILDING TYPE REGULATIONS

***Expand table to lock table headings in place while scrolling*** MS-2 & MX-1 | NX-2 | NX-3 | N-5 A. Building Siting. Refer to Figure 4.12-B Stacked Flats: Building Siting and 4.18.1 Building Siting for explanation. 1 | Multiple Principal Buildings | not permitted 2 | Minimum Front Lot Line Coverage | 65% 3 | Occupation of Corner | required 4 | Front Build-to Zone | within 2' of Building Line, minimum 10' deep front yard 5 | Corner Build-to Zone | within 5' of Building Line, minimum 10' deep corner side yard 6 | Minimum Side Setback | 7.5' 7 | Minimum Rear Setback | 15' | 5' | 20' 8 | Minimum Lot Width Maximum Building Width | 40' 35' 9 | Maximum Building Coverage Maximum Impervious Area Additional Semi-Pervious Area | 35% 60% 15% NOTE 1 | 40% 65% 15% NOTE 1 | 35% 60% 15% NOTE 1 10 | Parking & Detached Garage Location | rear yard 11 | Permitted Vehicular Access | one driveway per lot off corner side or interior side yard; shared driveways encouraged B. Height. Refer to Figure 4.12-C Stacked Flats: Height & Use Requirements and 4.18.2 Height for explanation. 12 | Minimum Overall Height | 2 stories 13 | Maximum Overall Height | 3 stories 14 | All Stories: (Measured floor-to-floor) Minimum Height Maximum Height | 9' 12' Figure 4.12-B Stacked Flats: Building Siting [image omitted; see the official code] Figure 4.12-C Stacked Flats: Height & Use Requirements [image omitted; see the official code] ***Expand table to lock table headings in place while scrolling*** MS-2 & MX-1 | NX-2 | NX-3 | N-5 C. Uses. Refer to Figure 4.12-C Stacked Flats: Height & Use Requirements and 4.18.3 Uses for explanation. Refer to 3.0 for permitted uses. 15 | All Stories | residential, lodging, & office uses permitted by district; maximum number of units per building defined by district | residential & lodging uses permitted by district; maximum number of units per building defined by district 16 | Parking within Building | not permitted 17 | Required Occupied Space | minimum 30' deep on all full floors from the front facade D. Street Facade Requirements. Refer to Figure 4.12-D Stacked Flats: Facade Requirements and 4.18.4 Street Facade Requirements for explanation. 18 | Minimum Transparency per each Story | 15% 19 | Blank Wall Limitations | required per floor on all stories of street facing facades (refer to 4.18.4 B. for requirements) 20 | Front Facade Entrance Type refer to 4.19.1 Entrance Types | stoop, porch 21 | Principal Entrance(s) Location | front facade 22 | Required Number of Street Entrances | minimum one, maximum of 2 per building; no exterior stairs permitted on any street or side facade 23 | Ground Story Vertical Facade Divisions | none required 24 | Horizontal Facade Divisions | none required 25 | Permitted Roof Types refer to 4.19.2 Roof Types | pitched, parapet, flat | parapet, flat 26 | Special Materials Requirements (refer to 4.2.1 Materials for general materials requirements) | none | none | none | primary building material shall be brick Figure 4.12-D Stacked Flats: Facade Requirements [image omitted; see the official code] E. Notes. The following notes are keyed to the requirements in the building type table, A through D: 1. Maximum impervious and semi-pervious area in any front yard (refer to 1.6) is 25 percent.

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.