For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.13.2 — ROW BUILDING TYPE REGULATIONS

Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.13.2

Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/75d5c658-9889-4399-a49a-cea009b9deff

4.13.2 - ROW BUILDING TYPE REGULATIONS

***Expand table to lock table headings in place while scrolling*** MX-1 | MX-2 | NX-1 | NX-2 | N-5 A. Building Siting. Refer to Figure 4.13-B Row Building: Building Siting and 4.18.1 Building Siting for explanation. 1 | Multiple Principal Buildings NOTE 1 | permitted | permitted NOTE 2 | permitted NOTE 2 | permitted NOTE 2 | permitted 2 | Minimum Front Lot Line Coverage | 90% | 90% | 80% | 80% | 85% 3 | Occupation of Corner | required | required | required | required | required 4 | Front Build-to Zone | within 2' of Building Line | within 2' of Building Line NOTE 2 | within 2' of Building Line NOTE 2 | within 2' of Building Line NOTE 2 | within 2' of Building Line 5 | Corner Build-to Zone | within 2' of Building Line | within 2' of Building Line | within 2' of Building Line | within 2' of Building Line | within 2' of Building Line 6 | Building Minimum Side Setback NOTE 4 Minimum Space between Buildings | 5' n/a | 5' 12' | 7.5' 15' | 7.5' 15' | 7.5' n/a 7 | Minimum Rear Setback | 10'; 5' on alleys | 20' 8 | Minimum Lot Width Maximum Building Width | None no limitation | None no limitation | None 4 vertical units; 90' | None 6 vertical units; 140' | None no limitation 9 | Maximum Building Coverage Maximum Impervious Area Additional Semi-Pervious Area | 60% 70% 20% NOTE 3 | 70% 80% 15% NOTE 3 | 55% 65% 15% NOTE 3 | 55% 65% 15% NOTE 3 | 50% 60% 15% NOTE 3 10 | Parking & Detached Garage Location | rear yard | rear yard | rear yard | rear yard | rear yard 11 | Permitted Vehicular Access | one driveway per lot off corner side or interior side yard; shared driveways encouraged B. Height. Refer to Figure 4.13-C Row Height & Use Requirements and 4.18.2 Height for explanation. 12 | Minimum Overall Height | 2 stories | 2 stories | 2 stories | 2 stories | 2 stories 13 | Maximum Overall Height | 4 stories | 4.5 stories | 3.5 stories | 3.5 stories | 2.5 stories 14 | All Stories: (Measured floor-to-floor) Minimum Height Maximum Height | 9' 14' | 9' 14' | 9' 12' | 9' 12' | 9' 12' Figure 4.13-B Row Building: Building Siting [image omitted; see the official code] Figure 4.13-C Row Height & Use Requirements [image omitted; see the official code] ***Expand table to lock table headings in place while scrolling*** MX-1 | MX-2 | NX-1 | NX-2 | N-5 C. Uses. Refer to Figure 4.13-C Row Height & Use Requirements and 4.18.3 Uses for explanation. Refer to 3.0 for permitted uses. 15 | Ground Story | any use permitted in the district | residential & lodging uses permitted by district; maximum number of units per building defined by district 16 | Upper Stories | residential & lodging uses, office uses 17 | Parking within Building | permitted fully in any basement and in rear of ground floor 18 | Entrance to Parking in Building | rear facade or interior side facade 19 | Required Occupied Space | minimum 30' deep on all full floors from the front facade D. Street Facade Requirements. Refer to Figure 4.13-D Row Building: Facade Requirements and 4.18.4 Street Facade Requirements for explanation. 20 | Minimum Transparency per each Story | 15% | 15% | 125 | 125 | 125 21 | Blank Wall Limitations | required per floor on all stories of street facing facades (refer to 4.18.4 B. for requirements) 22 | Front Facade Entrance Type refer to 4.19.1 Entrance Types | stoop, porch 23 | Principal Entrance Location per Unit NOTE 2 | front facade 24 | Required Number of Street Entrances NOTE 2, NOTE 5 | minimum one per building 25 | Ground Story Vertical Facade Divisions | none required 26 | Horizontal Facade Divisions | none required 27 | Permitted Roof Types refer to 4.19.2 Roof Types | parapet, pitched, flat; tower | parapet, flat; tower | parapet, pitched, flat | parapet, pitched, flat | pitched Figure 4.13-D Row Building: Facade Requirements [image omitted; see the official code] E. Notes. The following notes are keyed to the requirements in the building type table, A through D: 1. The Row Building must include 3 or more buildings, located either on the same lot or on adjacent lots, except that for existing buildings built before January 1, 1940, a Row Building Type may be used for just 2 buildings on adjacent lots. In case of a Row Building being developed on multiple lots, separate applications must be filed for each lot per 1.3.1 B.(6), and a certificates of occupancy for one Row Building shall not be issued until certificates of occupancy can be issued each contiguous building comprising the Row Building. When permitted, multiple buildings may be located on a lot with the minimum required space between them. However, each building shall fulfill all requirements of the Building Type unless otherwise noted. 2. Where multiple buildings are permitted, each building shall fulfill the Front Lot Line Coverage requirement except one of every 2 buildings may front a courtyard. Refer to 4.2.5 Courtyards for requirements. a. Entrances to buildings on courtyard may be off the courtyard. b. Facades on courtyard shall fulfill the Street Facade Requirements. 3. Maximum impervious and semi-pervious area in any front yard (refer to 1.6) is 25 percent. 4. The building minimum side setback and the minimum space between buildings shall be zero feet where a Row Building occupies the full length of the front lot line and neighboring lots are, or are reasonably anticipated to be, the Row Building type, and in the case of a Row Building on a corner, the building minimum side setback and the minimum space between buildings shall be zero feet on the side of the Row Building adjoining another building. 5. Each building must have one entrance oriented to the street, with each dwelling unit accessed through such street entrance, either directly from the street or through a common hallway. Each vertical unit may include up to one dwelling unit per floor.

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.