For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4.17.1 — PARKING STRUCTURES

Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.17.1

Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/cba72560-bcee-498d-b8be-58c52e92ac18

4.17.1 - PARKING STRUCTURES

Parking structures as the principal use on the lot require a special use permit (refer to 3.3.8 A.) and shall meet the following requirements: A. Materials. Major and minor material requirements shall be met on all street facades. Additional permitted secondary material is stained, finished concrete. B. Ramps and Slopes. Ramps and slopes shall be located on non-primary street or side street facades. C. Vertical Divisions. Vertical divisions the full height of the structure are required every 30 feet to de-emphasize the horizontal decks. Divisions shall be a minimum of 2 feet in width with a minimum projection of 2 inches. D. Blank Wall Limitations. No rectangular area greater than 30 percent of any story's facade, as measured from floor to floor, and no horizontal segment of a story's facade greater than 15 feet in width may be solid, blank wall. E. Entry Bay. A defined pedestrian entrance/exit is required separate from the vehicular entrance and directly accessing the sidewalk. If the space is enclosed, windows are required to meet a transparency rate of 65 percent. The entry bay shall include a roof type defined in 4.19.2 Roof Types. F. Vehicular Entrances. Access should be located on a non-primary street, when feasible. No more than 2 access points shall be located on any one street. Refer to 7.5 Site Access & Driveways for driveway widths and additional requirements. G. Parking Structures. It is recommended that the parking structure be designed in such a way that it can be converted to habitable use in the future, including, for example, reinforcement for additional loads, the minimization of ramping, fenestration of a size and dimension suitable for later window installation, flat slabs on the perimeter of the structure, and upper-story infrastructure that can be retrofitted support a roof, walls, and related material.

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.