§ 4.20.6 — ACCESSORY RENEWABLE ENERGY STRUCTURES
Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.20.6
Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/dc8efcef-843a-4093-bb48-042e931700b9
4.20.6 - ACCESSORY RENEWABLE ENERGY STRUCTURES
A. Solar Building-Mounted. A solar energy system that is affixed to or an integral part of a principal or accessory building, including but not limited to photovoltaic or hot water solar energy systems which are contained within roofing materials, windows, skylights, and awnings. (1) Quantity. The total square footage may not exceed the total area of roof surface of the structure to which the system is attached. (2) Flush Mounted System. Systems should be less than 4 inches from the roof surface whenever possible. (3) Height. (a) Systems shall not extend beyond 3 feet parallel to the roof surface of a pitched roof. (b) Systems shall not extend beyond 4 feet parallel to the roof surface of a flat roof. (c) Systems shall not extend more than 5 feet above the highest peak of a pitched roof. (4) Location on Structure. Allowed on the following: (a) Principal and accessory structures. (b) Any roof face. (c) Side and rear building facades. (5) Projection. The system may project off a roof edge or building facade as follows. (a) May project laterally from a building facade or roof edge a maximum of 3.5 feet. (b) May project into an interior side or interior rear setback, but shall be no closer than 5 feet to the interior side or interior rear property line. (6) Signs. Signage or writing of any kind is not permitted on any portion of system, other than required manufacturer plates and safety labeling. B. Solar Freestanding. A solar energy system with a supporting framework that is placed on, or anchored in, the ground and that is indepen dent of any building or other structure other than parking lot canopy solar energy systems described in 4.20.6 B. (1) Output. The system shall produce less than one megawatt of electricity. (2) Size. A system in any MX, N, or NX district shall not exceed either the area of 50 percent of the principal building footprint or 600 square feet, whichever is greater. (3) Maximum Height. The system shall be as close to the ground as practicable, and not taller than 20 feet on lots of at least 5 acres in the ID districts, 12 feet on lots of at least 5 acres, and 6 feet on all other lots, all measured from the grade at the base of the pole to the highest edge of the system. (4) Clearance. Minimum clearance between the lowest point of the system and the surface on which the system is mounted is 3 feet. (5) Location. Allowed in the interior side yard and interior rear yard only. (a) For any property designated as historic or located within a historic district, such system shall be located in the rear yard. (6) Setbacks. All parts of the freestanding system shall be set back a minimum of 5 feet from the interior side and interior rear property lines and shall not be located in a public utility easement. (7) Appearance. Such system must be gray, natural green, or beige in color, with the exception of the solar photovoltaic panels which are usually black, or system must be screened from view from surrounding residential properties. (8) Materials. Such system shall not include any unfinished lumber. C. Solar Parking Lot Canopy. A solar energy system with a supporting framework that is placed on, or anchored in, the ground and that is independent of any building or other structure, which is used in a parking lot or the top story of a parking structure to shade vehicles parked in such lot or structure. (1) Size. A system in any residential district (MX, N, or NX) shall not exceed either the area of 50 percent of the principal building footprint or 600 square feet, whichever is greater. (2) Maximum Height. The system shall be between 8 and 15 feet in height, so as to provide for parking underneath the system. (3) Clearance. Minimum clearance between the lowest point of the system and the surface on which the system is mounted is 7.5 feet. (4) Location. Allowed in the interior side yard and interior rear yard only, if applicable. (a) For any property designated as historic or located within a historic district, such system shall be located in the rear yard, if applicable. (b) Shall not cover more than 50 percent of the parking lot or story of the parking structure in which it is located. (5) Setbacks. All parts of the freestanding system shall be set back a minimum of 5 feet from the interior side and interior rear property lines and shall not be located in a public utility easement. (6) Appearance. Such system must be gray, natural green, or beige in color, with the exception of the solar photovoltaic panels which are usually black, or system must be screened from view from surrounding residential properties. Signage or writing of any kind is not permitted on any portion of any parking lot canopy solar energy system, other than required manufacturer plates or safety labeling. (7) Materials. Such system shall not include any unfinished lumber. D. Wind Freestanding. Small wind energy systems that stand independent of a building structure. (1) Output. The system shall produce less than one megawatt of electricity. (2) Location in City. System shall be located within 1,000 feet of an interstate or the Connecticut River. (3) Height. The height of any component of a small wind energy system shall not exceed 200 feet, as measured from the ground to highest point of the blade arc. (4) Permitted Yard Location. Allowed only in the interior side and interior rear yards. (a) Front, exterior side, and exterior rear yards may be allowed in non-residential districts with a special use permit provided there are no residential districts within 120 feet of any property line of the lot where the turbine will be located. (b) System shall not be visible from the street when installed on any property designated as historic or located within a historic district. (5) Setbacks. The base of the system shall be setback 1.1 times the height of the highest edge of the system from all property lines, overhead utility line poles, public sidewalks or trails, and public rights-of-way. Any system or any ancillary equipment shall not be located within any required setbacks of the respective zoning district (6) Installation. Small wind energy systems shall be installed only by professional installers certified to install wind turbines, and only pursuant to manufacturer specifications. (7) Signs. Signage or writing of any kind is not permitted on any portion of any wind turbine, other than required manufacturer plates or safety labeling. (8) Lighting. Small wind energy systems shall provide lighting per Federal Aviation Administration (FAA) regulations. Lighting shall be red and may not be of the incandescent variety, unless FAA regulations otherwise allow or require. (9) Clearance. Minimum clearance between the lowest tip of the rotor or blade and the ground is 10 feet. (10) Access. Climbing access (rungs or foot pegs) to the tower shall not start until 12 feet above grade to prevent unauthorized access. E. Wind Roof-Mounted. Wind energy systems that are attached to the roof of a building. (1) Quantity. One turbine is allowed for every 750 square feet of the combined roof area of all structures on a lot. For a pitched roof, each surface of the roof shall be included in the roof area calculation. (2) Rated Capacity. A maximum rated capacity of 3 kilowatts per turbine is allowed. (3) Height. (a) The maximum height of 15 feet is measured from the roof surface on which the system is mounted to the highest edge of the system with the exception of any pitches 10:12 or greater. (b) The system shall not extend more than 5 feet above the highest peak of a pitched roof. (4) Location. Roof-mounted wind energy systems are only permitted on structures that are a minimum of 4 stories tall or 40 feet. (a) Roof-mounted wind energy systems must be set back from the roof or parapet wall one foot for every foot in height of the device above the roof or parapet wall. (b) Roof-mounted wind energy systems shall only be permitted on roofs with a slope of one inch per foot or less. (c) A roof-mounted wind energy system shall not be visible from the street when installed on any property designated as historic or located within a historic district. (5) Installation. Roof-mounted wind energy systems shall be installed only by professional installers certified to install wind turbines, and only pursuant to manufacturer specifications.
Ask a question about Hartford law
Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.