§ 4.4.2 — DOWNTOWN GENERAL BUILDING TYPE REGULATIONS

Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 4.4.2

Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/5207bdd2-b373-409a-9570-5db3f2f93556

4.4.2 - DOWNTOWN GENERAL BUILDING TYPE REGULATIONS

***Expand table to lock table headings in place while scrolling*** DT-1NOTE 1 | DT-2NOTE 2 | DT-3NOTE 1 A. Building Siting. Refer to Figure 4.4-B Downtown General Building: Building Siting and 4.18.1 Building Siting. 1 | Multiple Principal Buildings | not permitted | not permitted | not permitted 2 | Minimum Primary Lot Line Coverage | 90% NOTE 3 | 90% NOTE 3 | 80% NOTE 3 3 | Occupation of Corner | required | required | required 4 | Primary Build-to Zone | at or maximum 15' behind the Building Line 5 | Secondary Build-to Zone | at or maximum 15' behind the Building Line 6 | Minimum Side Setback NOTE 9 | abutting adjacent building or minimum 7.5' 7 | Minimum Rear Setback NOTE 9 | 10' 8 | Minimum Lot Width Maximum Building Width | None none 9 | Building Coverage Maximum Impervious Area Additional Semi-Pervious Area | 90% no limitation 10% | 85% no limitation 10% | 90% no limitation 10% 10 | Permitted Parking & Loading Locations | rear yard or internal to building (refer to 4.4.2 C. Uses: Building Entrance to Parking requirement) 11 | Permitted Vehicular Access | one driveway permitted off each abutting secondary street; if no secondary street exists, the zoning administrator will determine the appropriate primary street access; circular drop-off drives permitted in DT-2 only B. Height. Refer to Figure 4.4-C Downtown General Building: Height & Use Requirements and 4.18.2 Height. 12 | Minimum Overall Height | 3 stories and 40' | 2 stories and 40' | 2 stories and 40' 13 | Maximum Overall Height | 38 stories; stepback required above 8 stories NOTE 4, NOTE 7 | 16 stories; stepback required above 8 stories NOTE 4, NOTE 7 | 8 stories; 5 stories on lower Main Street NOTE 5, NOTE 7 14 | Ground Story: (Measured floor-to-floor) Minimum Height Maximum Height | 13' 30' NOTE 6 | 9' 18' | 9' 14' 15 | Upper Stories: (Measured floor-to-floor) Minimum Height Maximum Height | 9' 14' | 9' 14' | 9' 14' Figure 4.4-B Downtown General Building: Building Siting [image omitted; see the official code] Figure 4.4-C Downtown General Building: Height & Use Requirements [image omitted; see the official code] ***Expand table to lock table headings in place while scrolling*** DT-1NOTE 1 | DT-2NOTE 2 | DT-3NOTE 1 C. Uses. Refer to Figure 4.4-C Downtown General Building: Height & Use Requirements and 4.18.3 Uses for explanation. Refer to 3.0 for permitted uses. 16 | Ground Story | Any use permitted by district is limited to no more than 25% of the ground floor area except that retail, service, and Adult Use Cannabis Uses, may occupy more floor area. Retail, service, and Adult Use Cannabis Uses shall be located at a street facade NOTE 8 17 | Upper Story | Any use permitted by district except retail, service and Adult Use Cannabis Uses 18 | Parking within Building | permitted fully in any basement and in rear of upper floors 19 | Entrance to Parking/Loading within Building | any rear, side, or Secondary Street facade 20 | Required Occupied Space | minimum 30' deep on all full floors from the Primary Street front facade D. Street Facade Requirements. Refer to Figure 4.4-D Downtown General Building: Street Facade Requirements and 4.18.4 Street Facade Requirements for explanation. 21 | Minimum Transparency on Ground Story of Front Façade measured between 2' and 8' above grade | 20% 22 | Minimum Transparency per each Story | 15% 23 | Blank Wall Limitations | required per floor on all stories (refer to 4.18.4 B. for requirements) 24 | Front Facade Entrance Type refer to 4.19.1 Entrance Types | stoop; arcade 25 | Principal Entrance Location | front, facade 26 | Required Number of Street Entrances | 1 per each 100' of front facade 27 | Ground Story Vertical Facade Divisions | every 100' of facade width 28 | Horizontal Facade Divisions | required within 3' of the top of the ground story and 5th floor above the first floor 29 | Permitted Roof Types refer to 4.19.2 Roof Types | parapet, pitched, flat; tower permitted Figure 4.4-D Downtown General Building: Street Facade Requirements [image omitted; see the official code] E. Notes. The following notes are keyed to the requirements in the building type table, A through D: 1. In DT-1 and DT-3, the Downtown Storefront Building Type is required to front all Primary Streets. Refer to the Zoning Map for the locations of Primary and Secondary Streets adjacent to these districts. 2. In DT-2 along Bushnell Park North (Ford and Jewell Streets) between Pearl and Trumbull Streets, Downtown Storefront Buildings are required to front towards the park. 3. A courtyard covering up to 35 percent of the front facade is permitted and may contribute to the Front Lot Line Coverage requirement, provided that a fence and landscaping fulfilling the requirements of 6.8 Frontage Buffer is provided along the building line. Refer to 4.2.5 Courtyards. Courtyard facades shall fulfill 4.4.2 D. Street Facade Requirements. 4. Above the 8th story, the upper stories of any building facade with street frontage shall have a step back from the lower stories that is a minimum of 12 feet and a maximum of 30 feet deep. 5. On Main Street south of Elm, the maximum height is 5 stories. 6. If 18 feet or more in height, ground story shall count as 2 stories towards maximum building height. 7. Property owners may exceed the maximum overall height set forth in 4.4.2 B.(13) by up to 6 stories by providing the following amenities: a. 2 additional stories permitted by providing a green roof covering 75 percent of the overall roof surface area. b. 3 additional stories for providing a functional green roof covering 50 percent of the overall roof surface area. c. 2 additional stories for providing on-site renewable energy fulfilling at least 25 percent of the energy needs of the building occupants. d. 3 additional stories for a combined heat and power system (cogeneration) fulfilling at least 50 percent of the heating and cooling needs of the building occupants. e. 2 additional stories for designating 15 percent of residential units to be affordable. 8. Any Eating Places (refer to 3.3.5 J.) or Adult Use Cannabis Uses (refer to 3.3.10) open to the public, but within the interior of the building, shall be located only on the first or second stories and shall be directly accessible from a public right of way. If located on the second story, "directly accessible" shall include being accessible through a small ground-story lobby containing an elevator and stairs. Allowed signage marking the entrance of the Eating Place shall be provided on the exterior of the building. 9. Where the wall of a building on an adjacent lot contains windows that have served, since November 1, 2016, as the primary means for obtaining natural light and air for more than 50 percent of the interior living or working spaces (excluding mechanical, storage spaces, and stairways) adjoining said wall, and where such wall is within 5 feet of the property line between the lot subject to the application and the adjacent lot, the zoning administrator or the commission, as applicable, may increase all or some portions of the rear and side setback requirements of the lot subject to the application by to up to 30 feet or may require the design of the building wall on that side to be stepped, upon a finding that the additional distance or a stepped design is required to ensure continued access to light and air to the existing living or working spaces.

(Amend. of 11-23-2021(2))

Ask a question about Hartford law

Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.