6.15.2 - DESIGN STANDARDS
Outdoor lighting fixture shall satisfy the following requirements: A. General. In general, all exterior light sources shall be directed downward and the illumination confined to necessary or useful areas. B. Maximum Light Levels at Property Line. (1) The maximum light level at any point on a property line shall not exceed: 0.1 footcandles within or adjacent to a residential property or a property in the N or NX districts, or 0.2 footcandles in other properties. (2) The zoning administrator or commission, as applicable, may determine that certain light fixtures are exempt from these requirements because they do not adversely affect an adjacent property owner, or because they are necessary for the functioning of the use. C. Type of Bulb. White light sources that include, without limitation, metal halide, fluorescent, or induction lamps, but excluding incandescent and halogen lamps, are required for any light fixture which exceeds 2,400 lumens that is within a parking lot, vehicular circulation, or pedestrian use area. Full cutoff high pressure sodium lamps, not exceeding a maximum lumen rating of 16,000 lumens, may be used in outdoor storage areas and other similar use areas not accessible to the general public and the need for good color rendering capabilities for safety and security is not necessary. D. Location. Light poles may be located as follows: (1) Light fixtures mounted on buildings or structures and light poles less than 7 feet in height may locate in any yard on any lot. (2) Light poles taller than 7 feet in height may be permitted through the site plan review process, depending on site conditions. E. Architectural Lighting of Building Facades. The lighting of a building facade for architectural, aesthetic, or decorative purposes is permitted subject to the following restrictions: (1) Upward aimed building facade lighting shall not exceed 900 lumens. All upward aimed light shall be fully shielded, fully confined from projecting into the sky by eaves, roofs, or overhangs, and mounted as flush to a wall as possible. (2) Building facade lighting exceeding 900 lumens shall be fully shielded, aimed downward, and mounted as flush to a wall as possible. (3) Building facade lighting shall be fully contained within the vertical surface of the wall being illuminated. (4) Building facade lighting that is measurable at the ground level shall be included in the maximum allowable light levels. F. Unshielded Lighting. (1) Motion-Activated Lighting. Unshielded, motion-activated lighting that emits more than 2,000 lumens but less than or equal to 6,000 lumens is permitted provided that it is activated by a motion sensor and provided it is aimed and located in such a manner as to prevent glare and light trespass. The light shall only go on when activated and go off within 5 minutes of activation. Motion sensor activated lighting shall not be triggered by any movement or activity located off the property on which the light is located. (2) Other unshielded lighting is prohibited, unless it can be shown that the type of fixture proposed is not objectionable because of the light distribution characteristics of the fixture. G. Parking Lot Lighting Curfews. On all non-residentially developed lots which contain a minimum of 4 parking lot light poles, parking lot lighting levels for ground surface parking lots and the top levels of parking decks or structures must be reduced by at least 50 percent of full operational levels within 30 minutes after the close of business. Lighting levels may be reduced by turning off 50 percent of the parking lot lights or by dimming parking lot lighting levels to no more than 50 percent of the levels used during business or activity hours within 30 minutes of the close of business, or by some combination thereof. Given that a certain minimum lighting level is recommended for safety and security purposes, this provision does not require parking lot lighting levels to be reduced to less than 0.2 footcandles as measured horizontally at the surface on which the light pole is mounted.
Ask a question about Hartford law
Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.