§ 6.2.3 — REQUIREMENTS
Code of Ordinances of the City of Hartford, Connecticut (Supp. No. 119: codified through Ordinance of May 11, 2026) · Hartford Zoning Regulations § 6.2.3
Corpus is an independent public-information project, not the official City of Hartford website. Stable reference: corpuslaw.us/code/0d99844b-dd81-41a4-98ca-555fbd9b0ed8
6.2.3 - REQUIREMENTS
The installation of landscaping shall adhere to the following standards. A. National Standards. Best management practices and procedures according to the nationally accepted standards shall be practiced. All landscaping and trees shall be installed in conformance with the practices and procedures established by the most recent edition of the ANSI A300 Part 5 (available from the Tree Care Industry Association). B. Installation. All landscaping shall be installed according to sound nursery practices in a manner designed to encourage vigorous growth. All landscape material, living and non-living, shall be healthy and in place prior to issuance of final certificate of completeness. (1) If seasonal conditions preclude the complete installation, a cash escrow or irrevocable letter of credit, equal to 1.5 times the installation costs as estimated by a qualified professional. (2) Complete installation is required within 9 months of the issuance of the temporary certificate of completeness or occupancy permit or the cash escrow or letter of credit may be forfeited. (3) For trees that were transported to the site with root balls contained with wire basket, burlap, or similar materials, as much of such materials as possible shall be removed from the planting location, to avoid girdling of roots as the tree matures. (4) A root flare must be exposed and at grade. C. Tree Measurement. Caliper is the measured diameter (inches) of the tree trunk as follows: (1) Caliper measurement of the trunk shall be taken 6 inches above the ground or top of the rootball up to and including 4 inch caliper size. (2) If the caliper at 6 inches above the ground exceeds 4 inches, the caliper should be measured at 12 inches above the ground or top of the rootball. (3) Caliper should be an average of measurements when a tree's trunk deviates significantly from a true circle. D. Plant Size Requirements. Plant material shall be sized according to Figure 6.2-A Plant Material Size at Installation unless otherwise noted in this section. Figure 6.2-A Plant Material Size at Installation ***Expand table to lock table headings in place while scrolling*** PLANT MATERIAL SIZE AT INSTALLATION Plant Material Type | Minimum Size Street Tree 1 | 2" caliper Deciduous Shade/Overstory Tree Single Trunk | 1.5" caliper Multi Trunk | 10' in height Evergreen Tree | 8' in height Understory Tree | 6' in height Ornamental Tree | 1.5" caliper Shrubs - Deciduous | 5 gallon container or 18" balled & burlaped Shrubs - Evergreen | 5 gallon container or 18" balled & burlaped Groundcover | 3" in height 1 Required size for street trees supersedes other tree size requirements. E. Condition and Selection of Planting Materials. The landscaping materials used shall be free from visible signs of disease, infestation, or physical defect at the time of planting. Plant materials shall: (1) Be appropriate for the conditions of the location, including sun and wind exposure, air quality, salt exposure, soil type, expected moisture content of soil, and slope. (2) Not be an invasive or a potentially invasive species as identified by the Connecticut Invasive Plant Working Group, the Connecticut Invasive Plants Council, as authorized in Connecticut Statute 22a-381b, or the State of Connecticut Department of Energy and Environmental Protection. (3) Be, wherever possible, native or naturalized to Connecticut. F. Compost, Mulch, and Organic Matter. Compost, mulch, and organic matter may be utilized within the soil mix to reduce the need for fertilizers and increase water retention. G. Establishment. All installed plant material shall be fully maintained until established, including watering, fertilizing, and replacement as necessary. Establishment is defined as survival in healthy and undamaged condition for a minimum of five years. The landowner, or successors in interest, or agent, if any, shall be jointly and severally responsible for maintenance and replacement. H. Permeable Surface. For each tree preserved or planted, a minimum amount of permeable surface area is required unless otherwise stated in these regulations. Refer to Figure 6.2-B, Required Soil Volumes & Permeable Area per Tree. Review 6.2.3.H (1) and (2) for feasibility. (1) At least 70 percent of the canopy limits of preserved trees should have a permeable surface. (2) Permeable area for one tree cannot count toward that of another tree. I. Structural Soil. (1) When the soil surface area of a tree will extend below any pavement, structural soil may be used underneath that pavement. Refer to Figure 6.2-B Recommended Soil Volumes & Permeable Area per Tree. (2) Structural soil is a medium that can be compacted to pavement design and installation requirements while still permitting root growth. It is a mixture of gap-graded gravels (made of crushed stone), clay loam, and a hydrogel stabilizing agent to keep the mixture from separating. It provides an integrated, root penetrable, high strength pavement system that shifts design away from individual tree pits. J. Required Soil Volume. When the required soil volume as outlined in Figure 6.2-B cannot be achieved, the following minimum requirements are to be met: 1. Minimum of 5x10x3 (150 cu ft) of soil is to be provided. 2. Required volume can be achieved by the use of structural soils or another method approved by the City Forester. Figure 6.2-B Required Soil Volumes & Permeable Area per Tree ***Expand table to lock table headings in place while scrolling*** REQUIRED SOIL VOLUMES & PERMEABLE AREA PER TREE Tree Size | Soil Volume | Soil Surface Area with 3' Soil Depth | Permeable Surface Area Requirement Very Small | 181 cubic feet | 72 square feet (approx. 8.5' x 8.5') | 25 square feet (5' x 5') Small | 736 cubic feet | 294 square feet (approx. 17' x 17') | 100 square feet (10' x 10') Medium | 2852 cubic feet | 1141 square feet (approx. 34' x 34') | 225 square feet (15' x 15') Large | 6532 cubic feet | 2681 square feet (approx. 50' x 50') | 400 square feet (20' x 20')
(Amend. of 2-22-2022(1))
Ask a question about Hartford law
Corpus searches the Hartford sections it holds and shows the ones that match, with their citations. Free, no sign-in.
