Sec. 6-45. - Zone regulations.

In all A8 zones and V8 zones as shown on the FIRM, the following provisions shall apply: (a) All new construction and substantial improvements (including the placement of prefabricated buildings and mobile homes) shall (i) be designed (or modified) and adequately anchored to prevent flotation, collapse, or lateral movement of the structure, (ii) be constructed with materials and utility equipment resistant to flood damage, and (iii) be constructed by methods and practices that minimize flood damage. (b) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems. (c) (1) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the system into floodwaters; and (2) On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding. (d) New construction or substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to or above base flood elevation. (e) New construction or substantial improvement of any commercial, industrial or other non-residential structure shall either have the lowest floor, including basement, elevated to the level of the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the building official prior to the issuance of a building permit for such structure. (f) Where interpretation is needed as to the exact location of the boundaries of the areas of special flood hazards the building official shall make the necessary interpretation. (g) Mobile homes shall not be permitted.

(Ord. of 5-9-77, § 5)

Ask a question about New London law

Corpus searches the New London sections it holds and shows the ones that match, with their citations. Free, no sign-in.