§ 132-59 — Lighting
Code of Ordinances of the City of Stamford, Connecticut (Supp. No. 73, Update 1: codified through Ordinance No. 1333, enacted September 8, 2026) · Stamford Code of Ordinances § 132-59
Corpus is an independent public-information project, not the official City of Stamford website. Stable reference: corpuslaw.us/code/57adbb1f-77cf-4bb5-92cf-cc725fd14c98
Sec. 132-59. - Lighting.
A. General. (1) Permanently fixed artificial light sources shall be installed to provide at least twenty (20) footcandles [two hundred fifteen (215) lux] of light on all food preparation surfaces and at warewashing work levels. (2) Permanently fixed artificial light sources shall be installed to provide, at a distance of thirty (30) inches [seven hundred sixty-two (762) millimeters] from the floor: (a) At least twenty (20) footcandles [two hundred fifteen (215) lux] of light in sales areas, utensil and equipment storage areas and in handwashing and toilet areas. (b) At least ten (10) footcandles [one hundred eight (108) lux] of light in walk-in refrigeration units, dry food storage areas and in all other areas. B. Protective shielding. (1) Lamps located over or within food storage, food preparation and food display facilities and facilities where utensils and equipment are cleaned and stored shall be shielded, coated or otherwise shatter resistant. (2) Infrared or other heat lamps shall be protected against breakage by a shield surrounding and extending beyond the bulb, leaving only the face of the bulb exposed.
Ask a question about Stamford law
Corpus searches the Stamford sections it holds and shows the ones that match, with their citations. Free, no sign-in.