§ 155-5 — Design standards
Code of Ordinances of the City of Stamford, Connecticut (Supp. No. 73, Update 1: codified through Ordinance No. 1333, enacted September 8, 2026) · Stamford Code of Ordinances § 155-5
Corpus is an independent public-information project, not the official City of Stamford website. Stable reference: corpuslaw.us/code/da76ea34-7a44-4f82-9135-b48f31268280
Sec. 155-5. - Design standards.
All Exterior Lighting shall meet the following requirements: a. Maximum Light Levels at Property Line. The light level at any point on a property line shall not exceed 0.1 footcandles in Residential Zoning Districts, or 0.2 footcandles in all other zoning districts except as follows: (1) The light emitted by Light Fixtures mounted on a structure built within five (5) feet of a public street right-of-way or sidewalk shall not exceed the maximum allowable light levels for "pedestrian areas" specified in Subsection 155-5.e for the underlying zoning district or use. The Maximum Allowable Light Level shall include any existing or proposed Street or Pedestrian Lighting located within the right-of-way. In no case shall the Maximum Allowable Light Level within the right-of-way, excluding street lights, exceed 0.2 footcandles when measured at the curbline. (2) In all non-residential zoning districts light levels exceeding 0.2 footcandles at the property line may be approved by the Director of Operations, or designee, upon finding that the increased light levels will not adversely affect an adjacent property owner. Evidence that the light will not adversely affect an adjacent property owner may include, without limitation, a statement from such property owner that it will not be adversely affected by the increased light levels. The maximum allowable light levels specified in Subsection 155-5.e of this section shall not be exceeded when measured on the property line. (3) Where a property in a Residential District abuts on a property in a non-residential district, for said property line the 0.1 footcandle limit shall apply. b. Aiming of light sources. All lighting shall be aimed: (1) Away from any adjacent property lines or public rights-of-way, except in instances where driveways, pedestrian walkways or parking areas are shared adjoining properties; and (2) Downward but no more than 75 degrees from the vertical, except as permitted in Subsections 155-5.d. and 155-5.m., and only if in compliance with Subsections 155-5.a and 155-5.b.(1) of this Chapter. c. White Light Source Required. White Light Sources that include, without limitation, LED, metal halide, fluorescent, or induction Lamps, but excluding incandescent and halogen Lamps, shall be required for any Luminaire which exceeds 2,400 lumens that is within a parking lot, driveways, or pedestrian area. d. Architectural Lighting of Building Facades. The lighting of a building facade for architectural, aesthetic, or decorative purposes is permitted subject to the following restrictions: (1) Upward aimed building facade lighting shall not exceed nine hundred (900) lumens. All upward aimed light shall be fully shielded, fully confined from projecting into the sky by eaves, roofs, or overhangs, and mounted as flush to a wall. (2) Building facade lighting exceeding nine hundred (900) lumens shall be fully shielded, aimed downward, and mounted as flush to a wall. (3) Building facade lighting shall be fully contained within the vertical surface of the wall being illuminated. (4) In Downtown and the South End, exceptions to the regulations in this Subsection shall be permitted under Subsection 155-7.c., "District Lighting Plans." e. Unshielded Lighting. (1) In all Zoning Districts, Unshielded Lighting emitting more than nine hundred (900) lumens shall be prohibited. (2) In all non-Residential Districts, Lamps emitting more than nine hundred (900) lumens shall be Fully Cutoff and Shielded, except as otherwise approved by the City of Stamford Engineering Bureau. (3) In all Residential Districts all Lamps less than nine hundred (900) lumens shall be within a Fully Shielded Fixture, or must be within a Light Fixture where the Lamp is obscured from view by a material that diffuses the light. (i.e., frosted or milk colored materials), except as otherwise permitted in this Chapter. f. Signs. All signs shall be required to meet the standards for this section, in addition to the Regulations of Section 13 of the City of Stamford Zoning Regulations. g. Lights Adjacent to Residential Districts. Standards for lights adjacent to Residential Zoning Districts, residential uses, or public rights-of-way: Any Light Fixture located within ten (10) feet of a property line of a residential zoning district, an existing residential use, or within ten (10) feet of a public right-of-way shall be: (1) Classified as an IESNA Type III or Type IV Light Fixture; and (2) Shielded on the side closest to the property line, Residential Zoning District, residential use, or public right-of-way. h. Full Cutoff Fixtures. Full Cutoff Fixtures shall be installed in a horizontal position as designed. i. Color Temperature. All Exterior Lighting shall have a Correlated Color Temperature of no more than three thousand (3,000) Kelvin. j. Shutoff Requirements. All Light Fixtures shall have automatic Daylight Adaptation Controls and Shutoffs. k. Maximum Pole Heights. The maximum height of light poles, including the base and Luminaire, shall not exceed the following heights: (1) In Residential Zoning Districts for surface parking areas with ten (10) or more parking spaces: Fifteen (15) feet. (2) In Residential Zoning Districts for pedestrian areas parking decks and similar structures higher than five (5) feet above the average finished grade, and parking areas with nine (9) or less spaces: Ten (10) feet. (3) In all other zoning districts for surface parking areas with ten (10) or more parking spaces: Twenty (20) feet. (4) In all other zoning districts for pedestrian areas and parking decks and similar structures higher than five (5) feet above the average finished grade, and parking areas with nine (9) or less spaces: Fifteen (15) feet. l. Canopy Lighting. Light Fixtures mounted under canopies used for vehicular shelter shall be aimed downward and installed in a way that the bottom of the Light Fixture is recessed or mounted flush with the bottom surface of the canopy. A Full Cutoff Light Fixture may project below the underside of a canopy. All light emitted by an under-canopy fixture shall be substantially confined to the ground surface directly beneath the perimeter of the canopy. No lighting, except that permitted by the Section 13 of the City of Stamford Zoning Regulations, shall be permitted on the top or sides of a canopy. m. Flagpoles and Statuary. Flagpoles and statuary may be illuminated by one (1) upwardly aimed Fully Shielded spotlight which shall not exceed three thousand five hundred (3,500) lumens. The Light Fixture shall be placed as close to the base of the flagpole or statuary as reasonably possible.
Ask a question about Stamford law
Corpus searches the Stamford sections it holds and shows the ones that match, with their citations. Free, no sign-in.