Sec. 46-162. - Sprinkler requirements.
(a) Places of assembly shall be sprinklered throughout in accordance with the most recently adopted edition of NFPA 13 when the following apply: (1) All new indoor places of assembly with an occupant load of 150 persons or greater. (2) Any interior renovations of 50 percent or more to an existing place of assembly with an occupant load greater than 150 persons. (3) Any additions or increase in interior size to an existing place of assembly that would create an occupant load of 150 persons or greater. (b) Places of assembly where alcohol is served for consumption on the premises shall be sprinklered throughout in accordance with the most recently adopted edition of NFPA 13 when the following apply: (1) All new indoor places of assembly with an occupant load of 100 persons or greater and where alcohol will be served for consumption on the premises. (2) Any interior renovation of 50 percent or more to an existing place of assembly with an occupant load greater than 100 persons and where alcohol will be served for consumption on the premises. (3) Any additions or increase in interior size to an existing place of assembly which would create an occupant load of 100 persons or greater and where alcohol will be served for consumption on the premises. (c) New educational occupancies of 5,000 square feet or greater shall be sprinklered throughout in accordance with the most recently adopted edition of NFPA 13. (d) Three feet of unobstructed clear width shall be designed, designated, and maintained around sprinkler risers for access by firefighters and for maintenance. The three feet shall be measured from the outermost components of the sprinkler riser and all related support equipment. (e) Fire department connections. Unless otherwise approved by the fire marshal, fire department connections shall be on the street side of the building and shall be located and arranged so that hose lines can be readily and conveniently attached without interference from any nearby obstructions as defined by the Fire Marshal's Office. Fire department connections shall be a five-inch Storz. Fire department connections shall be within 300 feet of an approved City of Dover Fire Hydrant and within 50 feet of the main entrance of the structure it serves. All fire department connections shall be not less than three feet nor more than five feet in height above finished grade. The fire marshal shall have the authority to require more stringent requirements when deemed necessary.
(Ord. of 3-14-2005; Ord. No. 2015-07, 5-26-2015; Ord. No. 2024-16, 6-24-2024)
Ask a question about Dover law
Corpus searches the Dover sections it holds and shows the ones that match, with their citations. Free, no sign-in.