§ 130-25 — Gas or liquid storage tanks
City Code of the City of Milford, Delaware (Supplement 29 Update 1 (2025-01-27)) · Milford City Code § 130-25
Corpus is an independent public-information project, not the official City of Milford website. Stable reference: corpuslaw.us/code/a8b612ac-4d2f-4cdd-b2af-fb4cd86f608a
§ 130-25. - Gas or liquid storage tanks.
(A) Underground tanks in special flood hazard areas shall be anchored to prevent flotation, collapse or lateral movement resulting from hydrostatic loads, including the effects of buoyancy, during conditions of the base flood. (B) Above-ground tanks in special flood hazard areas shall be elevated and anchored a minimum of 18 inches above the base flood elevation or shall be anchored at-grade and designed and constructed to prevent flotation, collapse, or lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the base flood. (C) In special flood hazard areas, tank inlets, fill openings, outlets and vents shall be: (1) At or above the base flood elevation or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tanks during conditions of the base flood. (2) Anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the base flood.
[Ord. No. 2014-16, §§ 1, 2, 1-26-2015; Ord. No. 2018-25, § 5, 11-26-2018]
Ask a question about Milford law
Corpus searches the Milford sections it holds and shows the ones that match, with their citations. Free, no sign-in.