§ 130-28 — Nonresidential structures and nonresidential portions of mixed use structures
City Code of the City of Milford, Delaware (Supplement 29 Update 1 (2025-01-27)) · Milford City Code § 130-28
Corpus is an independent public-information project, not the official City of Milford website. Stable reference: corpuslaw.us/code/42abf779-a71b-453a-a66f-3d871deb1cb5
§ 130-28. - Nonresidential structures and nonresidential portions of mixed use structures.
(A) Elevation Requirements. (1) The lowest floor (including basement) shall be elevated to at least 18 inches above the base flood elevation or the structure shall be dry floodproofed in accordance with § 130-28(B). (2) In areas of shallow flooding (Zone AO), if not dry floodproofed, the lowest floor (including basement) shall be elevated at least as high above the highest adjacent grade as the depth number specified in feet on the Flood Insurance Rate Map plus at least 18 inches, or at least 3.5 feet if a depth number is not specified; adequate drainage paths shall be provided to guide floodwaters around and away from the structure. (3) Enclosures below the lowest floor, if not dry floodproofed, shall meet the requirements of § 130-27(B). (B) Dry Floodproofing Requirements. Dry floodproofed structures, together with attendant utility and sanitary facilities, shall: (1) Be designed to be dry floodproofed such that the structure is watertight with walls and floors substantially impermeable to the passage of water to the level of the base flood elevation plus 18 inches. In areas of shallow flooding (Zone AO), the structure shall be dry floodproofed at least as high above the highest adjacent grade as the depth number specified in feet on the Flood Insurance Rate Map plus 18 inches, or at least 3.5 feet if a depth number is not specified. (2) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. (3) Be certified by a licensed professional engineer or licensed professional architect with a Floodproofing Certificate, that the design and methods of construction meet the requirements of this section. Refer to FEMA Technical Bulletin #3 - Non-Residential Floodproofing - Requirements and Certification for guidance.
[Ord. No. 2014-16, §§ 1, 2, 1-26-2015; Ord. No. 2018-25, § 7, 11-26-2018]
Ask a question about Milford law
Corpus searches the Milford sections it holds and shows the ones that match, with their citations. Free, no sign-in.