For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 88-2 — Additions, insertions and changes

City Code of the City of Milford, Delaware (Supplement 29 Update 1 (2025-01-27)) · Milford City Code § 88-2

Corpus is an independent public-information project, not the official City of Milford website. Stable reference: corpuslaw.us/code/822fa4cc-bbe5-4147-acd0-b87f4439c77e

§ 88-2. - Additions, insertions and changes.

The following sections are hereby revised: A. Chapter 1, Scope and Application . (1) Section R101.1. Insert: City of Milford (2) Section R105. Permits. (a) Add: Section R105.1. [1] Delaware Department of Transportation Approval. The building official may require an entrance/exit permit from the Delaware Department of Transportation upon application for a building permit for all nonresidential and residential buildings on state-maintained roads. [2] Other permit approvals. Before a building permit is issued, additional agency approvals may be required. Such agency approvals include, but are not limited to, Delaware State Fire Marshal, Kent/Sussex Conservation District, Delaware Division of Public Health, Delaware Department of Natural Resources and Environmental Control, and a Delaware-recognized electrical inspection agency. [3] Energy code compliance. An energy code compliance certificate shall be submitted with each single-family dwelling permit application, or meet the prescriptive requirements of Section 402 of the International Energy Conservation Code currently adopted by the State of Delaware. (b) Section R105.2, Work exempt from permit. Remove language under "Building:" and replace with the following; [1] One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 24 square feet. [2] Retaining walls which are not over four feet in exposed height, unless supporting a surcharge or impounding class I, II or III-A liquids. [3] Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. [4] Water tanks supported directly on grade if the capacity is not greater than 5,000 gallons and the ratio of height to diameter or width is not greater than 2:1. [5] Sidewalks and driveways. [6] Replacement of roof covering that does not involve the repair or replacement of more than 25 percent of the roof. [7] Prefabricated swimming pools accessory to a one- or two-family dwelling, which are less than 24 inches deep, do not exceed 5,000 gallons and are installed entirely above ground. [8] Swings and other playground equipment accessory to one- and two-family dwellings. [9] Window awnings supported by an exterior wall which do not project more than 54 inches from the exterior wall and do not require additional support. [10] Non-fixed and movable fixtures, cases, racks, counters and partitions not over five feet nine inches in height. (c) Add: R105.5.1. Time limitation of permit. A permit for any activity for which a permit is required shall be valid for one year from the date of issuance. (d) Add: R105.5.2. Completion of construction. All construction for which a building permit is required must be completed and pass final inspection within one year after issuance of a building permit. One extension of six months, accompanied by a renewal fee of a minimum of $50 or 10% of the original building permit fee, whichever is greater, may, at the discretion of the Code Official, be granted. (3) Section R108, Fees. (a) Add: R108.6.1. Violation fee. When obtaining a building permit after the start of construction, the building permit fee shall be assessed a violation fee as outlined in the adopted Planning and Economic Development Department Fee Schedule. (b) Add: R108.7. Delinquent taxes and fees. No building permits, certificate of occupancy, or certificate of completion shall be issued for a property if any of the following parties, having an interest in the application or the property the application is filed for, are not in good standing with the city: the applicant, the property owner, the equitable owner, the permit holder, or any individual with a controlling interest in the property (controlling interest means the acquisition of sufficient dominance to determine the operational and financial policies, including disposition of its assets, of any legal entity that is an applicant, property owner, equitable owner or permit holder, but excluding mortgage holders). "Not in good standing" means that at the time of the request a municipal lien has been imposed upon the property or any of the above enumerated parties are delinquent in the payment of monies owed to the city. (4) Add: 109.1.1.1. Waterproofing inspection. A waterproofing inspection will be required for all dwelling units with basements. The inspection will be required before the basement walls are backfilled. (5) Add: 109.1.1.2. As-Built Survey. An as-built survey prepared by a State of Delaware licensed professional surveyor or civil engineer shall be required for new structures and additions to existing structures as follows: (a) Foundation as-built survey shall be provided once the foundation has been constructed and prior to commencement of framing in the following instances: 1. All new structures other than residential accessory structures. 2. At any time when a variance from required area requirements was required for construction approval. 3. Where required by the building/code official. (6) Replace: Section R112. Board of Appeals. R112.1. General. Appeals of orders, decisions, or determination made by the Building and/or Code Official relative to the application and interpretation of this code, shall proceed as described in Article III of this Chapter. (7) Replace: R113.4. Violation penalties. Any person who shall violate a provision of this code or fails to comply with any of the requirements thereof or who shall erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the Building Official, or of a permit or certificate issued under the provisions of this code shall be guilty of a misdemeanor, punishable by a fine of not more than $500. Each day that a violation continues after due notice has been served shall be deemed as a separate offense. (8) Replace: R114.2. Unlawful continuance. Any person who shall continue any work in or about the structure after having been served with a stop work order, except such work as the person is directed to perform to remove a violation or unsafe condition shall be liable to a fine of not less than $500. B. Chapter 3, Building Planning. (1) Add: TABLE R301.2(1) Climatic and Geographic Design Criteria Ground Snow Load | Wind Design | Seismic Design Category | Subject to Damage From | Winter Design Temp | Ice Barrier Underlayment Required | Flood Hazards | Air Freezing Index | Mean Annual Temp Speed | Topo- graphic Effects | Special Wind Region | Windborne Debris Zone | Weathering | Frost Line Depth | Termite 25 lbs./sq. ft. | 115 mph | No | No | No | A | Severe | 24" | Mod- Heavy | 18°F | Yes | 9/14/1992 1/06/2005 7/7/2014 3/16/2015 | 596 | 54°F Manual J Design Criteria Elevation | Latitude | Winter Heating | Summer Cooling | Altitude Correction Factor | Indoor Design Temp | Design Temp Cooling | Heating Temp Difference 23 ft. | 39° | 18°F | 89°F | 10 | 72°F | 75°F | 56°F Cooling Temp Difference | Wind Velocity Cooling | Coincident Wet Bulb | Daily Range | Winter Humidity | Summer Humidity 14°F | 15 mph | 7.5 mph | 75 | M | 50% | 50% (2) Add: Section 310.2.5.1. Replacement Window. At least one emergency escape and rescue opening complying with Section 310.2 is required in any sleeping room that is being added or gutted due to renovation to a structure. (3) Replace: R 311.7.5.1 Risers. The maximum riser height shall be 8-1/4 inches (209.6 mm). The riser shall be measured vertically between leading edges of the adjacent reads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). The riser height at landings with hinged doors shall be measured from the landing vertically to the top of the threshold (not the compression strip). The riser height at landings with sliding doors shall be measured from the landing vertically to the top of the highest projection of the door track. Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 6-inch-diameter (102 mm) sphere. Exceptions: (a) The opening between adjacent treads is not limited on spiral stairways. (b) The riser height of spiral stairways shall be in accordance with Section R311.7.10.1. (4) Replace: R311.7.5.2 Treads. The minimum tread depth shall be 9 inches (229 mm). The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm). (5) Replace: R313.1 Townhouse automatic fire sprinkler systems. An automatic residential fire sprinkler system may be installed in townhouses. (6) Replace R313.2 One- and two-family dwellings automatic fire sprinkler systems. An automatic fire sprinkler system may be installed in one- and two-family dwellings. (7) Replace: R315.2.1. New Construction. For new construction, carbon monoxide alarms shall be provided in dwelling units. (8) Replace: R324.6. Roof access and pathways. Roof access, pathways and setback requirements shall be provided in accordance with Sections R324.6.1 and R324.6.2, through R324.6.2.1. Access and minimum spacing shall be required to provide emergency access to the roof, to provide pathways to specific areas of the roof, to provide for smoke ventilation opportunity areas, and to provide emergency egress from the roof. (9) Replace: R324.6.1. Pathways. A 36" pathway shall be provided on all edges, valleys and hips of roofs. Pathways on townhomes shall maintain at least 18" from the property line if the roof on either side of the property line shares the same plane. If the plan of the roof is different, a 36" pathway shall be provided on each side. (10) Replace: R324.6.2. Setback at ridge. A 36" clear setback is required on each side of the horizontal ridge. (11) Delete: R324.6.2.1. Alternative setback at ridge. C. Chapter 4, Foundations. (1) Replace: R403.1.1. Minimum Size. All continuous footings shall be a minimum of 8" depth by 16" width. Footings shall be sized to support the imposed loads. Footing projections, P, shall not be less than 2 inches and shall not exceed the thickness of the footing. Footing thickness and projection for fireplaces shall be in accordance with Section R1001.2. The size of footings supporting piers and columns shall be based on the tributary load and allowable soil pressure in accordance with Table R401.4.1. Footings for wood foundations shall be in accordance with details set forth in Section R403.2, and Figures R403.1(2) and R403.1(3). Footings for precast foundations shall be in accordance with details set forth in Section R403.4, Table 403.4, and Figures R403.4(1) and R403.4(2). Exceptions: (a) Minimum footings for single-story decks shall be 3 times the widest nominally measured side of the post. Footings must also be sized to support the imposed loads; interior post locations support more weight than perimeter posts. (b) Decks having vertical members spaced 6 feet on center or less may be placed on a 4-inch concrete pad, provided the vertical members are placed 12 inches inside the perimeter of the pad and are anchored on all corners with approved anchoring devices. Decks 20 feet or more in length shall have two additional anchors installed on each side mid-span. (c) Residential accessory structures less than 300 square feet in area, with the exception of a pole building or garage, shall be leveled and secured with tie-downs or equivalent manufactured home anchoring devices, one in each corner. Structures 20 feet or more in length shall have two additional anchors installed on each side mid-span. All lumber and wood siding is to be pressure treated from grade to 8 inches above finished grade. Pressure-treated lumber shall meet the requirements set forth in Section R317. (d) Prefabricated room enclosures are to be placed on an approved support system per the manufacturer's installation instruction. (2) Replace: R405.1. Concrete or masonry foundations. Drains shall be provided around concrete or masonry foundations that retain earth and enclose crawl space/basements of habitable or usable spaces located below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or materials shall be installed at or below the top of the footing or below the bottom of the slab and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend not less than 1 foot above the top of the footing and be covered with an approved filter membrane material. The top of open joints of the drain tiles shall be protected with strips of building paper. Except where otherwise recommended by the drain manufacturer, perforated drains shall be surrounded with an approved filter membrane or the filter membrane shall cover the washed gravel or crushed rock covering the drain. Drainage tiles or perforated pipe shall be placed on not less than two inches of washed gravel or crushed rock not less than one sieve size larger than the tile joint opening or perforation and covered with not less than six inches of the same material. Exception: A drainage system is not required where the foundation is installed on well-drained ground or sand-gravel mixture soils according to the unified Soil Classification System, Group 1 soils, as detailed in Table R405.1 (3) Replace: R405.2.3. Drainage systems. In other than Group 1 soils, a sump shall be provided to drain the porous layer and footings. The sump shall be not less than 24 inches in diameter or 20 inches square, shall extend not less than 24 inches below the bottom of the crawl space or basement floor and shall be capable of positive gravity or mechanical drainage to remove any accumulated water. The drainage system shall discharge into an approved sewer system or to daylight. D. Chapter 5, Floors. (1) Add: R502.3.4. Deck floor joist spans. Deck floor joist spans shall be in accordance with American Forest and Paper, Design for Acceptance #6, Prescriptive Residential Wood Deck Construction Guide. (2) Add: R502.5.1. Deck girder spans. Deck girder spans shall be in accordance with the American Forest and Paper, Design for Acceptance #6, Prescriptive Residential Wood Deck Construction Guide. E. Chapter 6, Wall Construction. (1) Replace: R602.10. Wall bracing. Buildings shall be braced in accordance with this section or, when applicable, Section R602.12. Where a building or portion thereof, does not comply with one or more of the bracing requirements in this section, those portions shall be designed and constructed in accordance with Section R301.1. Exception: Porches with roofs and screen porches shall not be required to comply with the requirements of R602.10 Wall Bracing, when constructed with approved translucent or transparent plastic not more than 0.125 inch in thickness. (2) Add: R611.1. Definitions. POST FRAME BUILDING: A structural building frame consisting of a wood truss or rafters connected to vertical timber columns or sidewall posts, which function as the principal gravity and load resisting elements of the building. A building used for motor vehicles is considered a garage and must meet the requirements in Section R309 as well as Section 614 of this code. (3) Add: R612.1. Design loads. Plans are required to meet the minimum design loads noted in Table 301.2(1). Uplift reaction forces involved are required to be provided. (4) Add: R612.2. Truss design drawings. Truss design drawings are required at the time of plan submittal. The building plans should specify the permanent bracing for cords and webs to meet the bracing requirements shown on the truss design drawings. (5) Add: R612.3. Size, grade and species of wood members. All lumber shown on the submitted drawings should identify the size, grade and species or species group. Any engineered lumber should be identified by the product name, size and stress grade. (6) Add: R612.4. Isolation of siding. Methods and materials to isolate siding from preservative treated lumber should be specified 26 and detailed on the submitted plans. (7) Add: R612.5. Construction of truss carrier to bearing post. Submitted plans shall specify a bearing notch, properly designed bearing block, or other means for positive load transfer. (8) Add: R612.6. Fastener schedule. Submitted plans are required to include a fastener schedule completely describing the fasteners and quantities required at each connection. Power-driven nails should specify the type, diameter and length. (9) Add: R612.7. Roofing and siding diaphragms. Submitted plans shall include metal roof and wall panel thickness, fastener type and size, and the fastener pattern for roof and siding panels. If stitch screws are required to attach metal sheet-to-sheet, the plans should show the locations. Shingles roofs shall meet the requirements of Section R905. (10) Add: R613.1. Footing depth. Footings for post frame structures shall extend a minimum of 40 inches below grade. (11) Add: R613.2. Footing size. Footings for all post frame structures shall be sized to support the loads imposed. Minimum footing sizes for all post frame structures shall be 18 inches diameter and a minimum of 12 inches thick concrete under the support posts. (12) Add: R613.3. Resistance to uplift. A lumber cleat shall be attached to the bottom of all vertical support posts to resist uplift. Exception: Other means to resist uplift may be used and should be noted on the submitted plans. (13) Add: R614.1. Preservative treatment. All wood in contact with the ground shall be preservative-treated meeting the requirements of Section R319. (14) Add: R614.2. Support posts. Support posts fabricated from multiple plies shall have the number of plies of lumber, lumber species, grade, and connection system between plies noted. (15) Add: R614.3. Truss carrier spans. The allowable spans for truss carriers shall support the load of the proposed roof structure and floor system if present. Fabricated or dimensional lumber shall not exceed the values set forth in Tables R617.4(1) through R617.4(3). Spans exceeding the values set forth in Tables R617.4(1) through R617.4(3) shall be engineered. F. Appendix C, Exit Terminals of Mechanical Draft and Direct-Venting Systems. Adopt without changes. G. Appendix E, Manufactured Housing as Dwellings. Adopt without changes. H. Appendix J, Existing Buildings and Structures. Adopt without changes. I. Appendix Q, Tiny Houses. Adopt without changes.

[Ord. No. 2022-19, § 4, 7-11-2022; Ord. No. 2024-03, § 6, 1-22-2024]

Ask a question about Milford law

Corpus searches the Milford sections it holds and shows the ones that match, with their citations. Free, no sign-in.