§ 19-238 — Technical amendments to the Florida Building Code relating to flood-resistant design and drainage
Code of Ordinances, City of Boca Raton, Florida (Supp. 72 Update 2: codified through Ordinance of June 9, 2026 (online updated October 20, 2026)) · Boca Raton Code of Ordinances § 19-238
Corpus is an independent public-information project, not the official City of Boca Raton website. Stable reference: corpuslaw.us/code/0cae5c9c-0a91-4576-8ffd-ccf09a95255e
Sec. 19-238. - Technical amendments to the Florida Building Code relating to flood-resistant design and drainage.
(1) Cumulative substantial improvement. For purposes of applying the requirements of the Florida Building Code, Building, and the Florida Building Code, Existing Building, as the same may be amended by this Code of Ordinances, and as used in this chapter, the term "substantial improvement" have the same meaning as that found in section 21-2. (2) Minimum building elevations: (a) In flood hazard areas, buildings and structures shall have: the lowest floor, dry floodproofing measures, or the bottom of the lowest horizontal structural member of the lowest floor, as applicable to occupancy and flood zone, at or above the highest of: (i) the base flood elevation plus 1 foot, (ii) the design flood elevation, (iii) the South Florida Water Management District permit minimum required finished floor elevation (if applicable), or (iv) 1.5 feet above the crown of road. (b) In areas identified as Zone AO, buildings and structures shall have: the lowest floor or dry floodproofing measures, as applicable to occupancy, at or above the highest of: (i) the highest adjacent grade of not less than the depth number specified in feet on the FIRM plus 1 foot, not less than 3 feet if a depth number is not specified, (ii) the South Florida Water Management District permit minimum required finished floor elevation (if applicable), or (iii) 1.5 feet above the crown of road. (c) In non-flood hazard areas, new buildings and structures shall have the lowest floor at or above the South Florida Water Management District permit minimum required finished floor elevation (if applicable), or 1.5 feet above the crown of road, whichever is higher. (d) In non-flood hazard areas, any addition to existing buildings and structures that is considered a "substantial improvement," as defined in section 21-2, shall require the lowest floor to be at or above the South Florida Water Management District permit minimum required finished floor elevation (if applicable), or 1.5 feet above the "crown of road," as defined in section 19-3, whichever is higher. In the event there is any existing finished floor that does not meet this requirement, such existing finished floor must be raised to comply. Any addition that is not considered a "substantial improvement," as defined in section 21-2, shall have the lowest floor at or above the South Florida Water Management District permit minimum required finished floor elevation or, in the event the South Florida Water Management District permit minimum required finished floor elevation is not applicable, the lowest floor of at the addition shall be at or above the lowest finished floor elevation of the existing building(s) or structure(s).
(Ord. No. 5455, § 2, 5-22-18; Ord. No. 5720, § 4, 12-10-24)
Ask a question about Boca Raton law
Corpus searches the Boca Raton sections it holds and shows the ones that match, with their citations. Free, no sign-in.